Automated Kjeldahl Nitrogen Analyzer
自动凯氏氮分析仪
- SKU KJS-0004
- Kjeldahl Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IQ/OQ documentation (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Automated steps | Dosing, digestion, distillation, titration |
|---|---|
| Digestion temperature | Up to 420 °C |
| Cycle time | 4–8 min per sample after digestion |
| Throughput | 20–60 samples/h |
| Nitrogen range | 0.1–200 mg N per sample |
| Repeatability | RSD ≤ 1 percent |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 1871, ISO 8968-1, ISO 5983-2
What is the Automated Kjeldahl Nitrogen Analyzer?
An automated Kjeldahl nitrogen analyzer links digestion, distillation and titration in one controlled workflow and reports nitrogen or protein directly. It suits busy laboratories processing many samples with strict regulatory traceability requirements.
What is the Automated Kjeldahl Nitrogen Analyzer?
An automated Kjeldahl nitrogen analyzer links digestion, distillation and titration in one controlled workflow and reports nitrogen or protein directly. It suits busy laboratories processing many samples with strict regulatory traceability requirements.
Overview
The analyzer automates the whole sequence: reagent dosing for digestion, temperature programming with fume scrubbing, transfer to the distillation stage, alkali addition, steam distillation and titration to a potentiometric endpoint. Results are calculated from the titration volume and displayed as nitrogen or protein using a stored conversion factor, and methods, reagent lots and calibration data are recorded for traceability. Because the steps are linked, operator contact with hot acid and alkali is minimised and intermediate transfer losses are reduced, improving repeatability below one percent relative. Cycle times are typically four to eight minutes per sample after digestion, and the systems usually report blank-corrected results with control charting and automatic flagging of out-of-range values.
How does it work?
The Kjeldahl method converts nitrogen in the sample to ammonium sulfate by heating with concentrated sulfuric acid and a catalyst, usually copper or selenium with potassium sulfate to raise the boiling point. Organic matter is oxidised and the nitrogen is retained as ammonium. The digest is then made alkaline with sodium hydroxide, releasing ammonia, which is steam-distilled into a receiver containing boric acid or a standard acid. The amount of ammonia is determined by titration, and nitrogen content is calculated from the titre. A conversion factor, typically 6.25 for food, 6.38 for milk or 5.7 for wheat flour, converts nitrogen into protein. Blank determinations, catalyst choice and digestion completeness are the main factors that determine accuracy, and the method is the traditional reference for protein content.
What are the key features?
- Integrated digestion, distillation and titration sequence
- Stored methods with automatic reagent dosing
- Potentiometric titration with automatic endpoint
- Direct nitrogen or protein calculation with factor library
- Batch control charts and out-of-range flagging
- Full audit trail and LIMS export
What are the technical specifications?
A typical automated kjeldahl nitrogen analyzer configuration offers automated steps of Dosing, digestion, distillation, titration, digestion temperature of Up to 420 °C, cycle time of 4–8 min per sample after digestion, throughput of 20–60 samples/h, nitrogen range of 0.1–200 mg N per sample and repeatability of RSD ≤ 1 percent. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Kjeldahl Nitrogen Analyzer is used in high-throughput food and feed protein testing, accredited reference protein analysis, milk powder and dairy nitrogen control and method validation and proficiency samples. Across the wider Kjeldahl Systems class, laboratories also deploy it for reference protein determination in food and feed, milk and dairy nitrogen testing and cereal, flour and grain protein measurement.
Which standards and certifications apply?
Relevant standards and methods include ISO 1871, ISO 8968-1, ISO 5983-2, AOAC 2001.11, AOAC 920.87 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and IQ/OQ documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Kjeldahl work involves concentrated sulfuric acid, hot sodium hydroxide and noxious fumes, so a fume hood, an exhaust scrubber and acid-resistant surfaces are required, along with gloves, goggles and a face shield. Digestion must be complete and free of charring; adding hydrogen peroxide or using a catalyst mixture helps, and selenium catalysts need careful handling because of toxicity. The distillation apparatus must be steam-tight and conditioned before the first sample to avoid low recoveries, and blank values should be subtracted for each batch. The standard acid and sodium hydroxide solutions need regular standardisation, and titrators should be checked with certified materials. Document temperatures, times, reagent batches and catalyst lots.
How do I select the right Automated Kjeldahl Nitrogen Analyzer?
Choose an integrated analyzer when sample numbers are high and traceability and low operator exposure are priorities. Confirm cycle time and throughput against your workload, and check that the method library supports the conversion factors and matrix programmes you need. Request IQ/OQ support if results are used for regulated release.
How does it compare with other Kjeldahl Systems variants?
Choose the scale of the system from your sample numbers and the accuracy you need. Manual digestion blocks with six to twelve positions suit low-throughput laboratories and teaching use but demand careful timing and fume control. Automated digestion blocks add temperature programming, exhaust scrubbing and unattended runs, which improve safety and reproducibility. Steam distillation units with automatic alkali addition and titration cut operator time and variability and are the core of routine Kjeldahl work. Integrated analyzers link digestion, distillation and titration in one workflow and are convenient where many samples are processed daily. Micro-Kjeldahl systems use smaller sample and reagent volumes, which reduces waste and is useful when sample material is limited. Whatever the scale, confirm recovery with reference materials.
Full specifications
| Automated steps | Dosing, digestion, distillation, titration |
|---|---|
| Digestion temperature | Up to 420 °C |
| Cycle time | 4–8 min per sample after digestion |
| Throughput | 20–60 samples/h |
| Nitrogen range | 0.1–200 mg N per sample |
| Repeatability | RSD ≤ 1 percent |
| Titration | Potentiometric, automatic endpoint |
| Conversion factors | Stored library, 5.7 to 6.38 |
| Data management | Audit trail, control charts, LIMS export |
| Safety | Scrubber, interlocks, enclosed reagent handling |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-throughput food and feed protein testing
- Accredited reference protein analysis
- Milk powder and dairy nitrogen control
- Method validation and proficiency samples
Key features
- Integrated digestion, distillation and titration sequence
- Stored methods with automatic reagent dosing
- Potentiometric titration with automatic endpoint
- Direct nitrogen or protein calculation with factor library
- Batch control charts and out-of-range flagging
- Full audit trail and LIMS export
Frequently asked questions about Automated Kjeldahl Nitrogen Analyzer
It removes manual reagent addition, transfer and titration, so hands-on time falls to loading tubes and confirming results. Most laboratories report that the analyser pays back through higher throughput and fewer repeat analyses.
Yes, provided the instrument is qualified and the method is validated for your matrices, and provided the software records an audit trail. Many accredited laboratories use integrated analyzers with formal IQ/OQ/PQ documentation.
The system rinses tubing and the distillation path between samples, and distilled blanks are run at intervals. Where carryover is critical, a blank is distilled after high-nitrogen samples to demonstrate that residue is below the acceptance limit.
It is the traditional reference method accepted by pharmacopoeias, food regulations and feed standards, and it is robust across many matrices. Its direct acid digestion step also makes it suitable for referee analysis and for validating faster combustion methods.
Copper sulfate and selenium are the common catalysts, usually with potassium sulfate to raise the boiling point of the acid mixture. Copper is less toxic but slower, while selenium is faster but requires careful handling and disposal.
Reagents, glassware and laboratory air contribute small amounts of nitrogen that would be counted as sample nitrogen. A blank carried through digestion, distillation and titration gives that contribution, which is subtracted from each result.