Steam Distillation Unit for Kjeldahl Nitrogen
凯氏氮蒸汽蒸馏装置
- SKU KJS-0003
- Kjeldahl Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Distillation capacity | 1–6 tubes per cycle |
|---|---|
| Alkali dosing | Automatic, 0–100 mL |
| Steam rate | Adjustable, 30–100 percent |
| Distillation time | 3–6 min per sample |
| Throughput | 20–40 samples/h |
| Receiver | Boric acid or standard acid |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 1871, ISO 8968-1, ISO 5983-2
What is the Steam Distillation Unit for Kjeldahl Nitrogen?
A steam distillation unit adds alkali to the digest, distils the released ammonia into a receiver and can titrate it automatically. It is the core of routine Kjeldahl nitrogen and protein determination.
What is the Steam Distillation Unit for Kjeldahl Nitrogen?
A steam distillation unit adds alkali to the digest, distils the released ammonia into a receiver and can titrate it automatically. It is the core of routine Kjeldahl nitrogen and protein determination.
Overview
The digested sample is placed in a distillation tube, sodium hydroxide is added automatically to make it alkaline, and steam generated in a separate vessel drives ammonia over into a receiver containing boric acid or standard acid. Automatic units control alkali volume, distillation time and steam rate, and many add a titration step with potentiometric or colorimetric endpoint detection, so the result is calculated directly as nitrogen or protein. A distillation unit must be steamed out before the first sample and between samples to avoid carryover, and the blank is distilled in the same batch. Typical distillation takes three to six minutes per sample, giving throughputs of 20 to 40 samples per hour, with recovery checked using ammonium sulfate or ammonium chloride standards.
How does it work?
The Kjeldahl method converts nitrogen in the sample to ammonium sulfate by heating with concentrated sulfuric acid and a catalyst, usually copper or selenium with potassium sulfate to raise the boiling point. Organic matter is oxidised and the nitrogen is retained as ammonium. The digest is then made alkaline with sodium hydroxide, releasing ammonia, which is steam-distilled into a receiver containing boric acid or a standard acid. The amount of ammonia is determined by titration, and nitrogen content is calculated from the titre. A conversion factor, typically 6.25 for food, 6.38 for milk or 5.7 for wheat flour, converts nitrogen into protein. Blank determinations, catalyst choice and digestion completeness are the main factors that determine accuracy, and the method is the traditional reference for protein content.
What are the key features?
- Automated alkali addition and steam distillation
- Steam generator with controlled flow and time
- Boric acid or standard acid receiver options
- Integrated potentiometric or colorimetric titration
- Direct display of nitrogen or protein result
- Sample capacity from one to six tubes per cycle
What are the technical specifications?
A typical steam distillation unit for kjeldahl nitrogen configuration offers distillation capacity of 1–6 tubes per cycle, alkali dosing of Automatic, 0–100 mL, steam rate of Adjustable, 30–100 percent, distillation time of 3–6 min per sample, throughput of 20–40 samples/h and receiver of Boric acid or standard acid. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Steam Distillation Unit for Kjeldahl Nitrogen is used in routine protein determination in food and feed, milk and dairy nitrogen testing, water, wastewater and soil ammonia nitrogen and referee and confirmatory protein analysis. Across the wider Kjeldahl Systems class, laboratories also deploy it for reference protein determination in food and feed, milk and dairy nitrogen testing and cereal, flour and grain protein measurement.
Which standards and certifications apply?
Relevant standards and methods include ISO 1871, ISO 8968-1, ISO 5983-2, AOAC 2001.11, AOAC 920.87 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Kjeldahl work involves concentrated sulfuric acid, hot sodium hydroxide and noxious fumes, so a fume hood, an exhaust scrubber and acid-resistant surfaces are required, along with gloves, goggles and a face shield. Digestion must be complete and free of charring; adding hydrogen peroxide or using a catalyst mixture helps, and selenium catalysts need careful handling because of toxicity. The distillation apparatus must be steam-tight and conditioned before the first sample to avoid low recoveries, and blank values should be subtracted for each batch. The standard acid and sodium hydroxide solutions need regular standardisation, and titrators should be checked with certified materials. Document temperatures, times, reagent batches and catalyst lots.
How do I select the right Steam Distillation Unit for Kjeldahl Nitrogen?
Select a steam distillation unit with automatic alkali dosing and, if throughput justifies it, integrated titration. Confirm the distillation time, nitrogen range and recovery that your method requires, and that receivers and reagents suit the titration chemistry you use. Check whether an autosampler is needed for your sample numbers.
How does it compare with other Kjeldahl Systems variants?
Choose the scale of the system from your sample numbers and the accuracy you need. Manual digestion blocks with six to twelve positions suit low-throughput laboratories and teaching use but demand careful timing and fume control. Automated digestion blocks add temperature programming, exhaust scrubbing and unattended runs, which improve safety and reproducibility. Steam distillation units with automatic alkali addition and titration cut operator time and variability and are the core of routine Kjeldahl work. Integrated analyzers link digestion, distillation and titration in one workflow and are convenient where many samples are processed daily. Micro-Kjeldahl systems use smaller sample and reagent volumes, which reduces waste and is useful when sample material is limited. Whatever the scale, confirm recovery with reference materials.
Full specifications
| Distillation capacity | 1–6 tubes per cycle |
|---|---|
| Alkali dosing | Automatic, 0–100 mL |
| Steam rate | Adjustable, 30–100 percent |
| Distillation time | 3–6 min per sample |
| Throughput | 20–40 samples/h |
| Receiver | Boric acid or standard acid |
| Titration | Potentiometric or colorimetric endpoint |
| Nitrogen range | 0.1–200 mg N per sample |
| Recovery check | Ammonium sulfate or ammonium chloride |
| Interface | USB, LIMS export, audit trail |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine protein determination in food and feed
- Milk and dairy nitrogen testing
- Water, wastewater and soil ammonia nitrogen
- Referee and confirmatory protein analysis
Key features
- Automated alkali addition and steam distillation
- Steam generator with controlled flow and time
- Boric acid or standard acid receiver options
- Integrated potentiometric or colorimetric titration
- Direct display of nitrogen or protein result
- Sample capacity from one to six tubes per cycle
Frequently asked questions about Steam Distillation Unit for Kjeldahl Nitrogen
Residual ammonia from previous runs or from reagents can be carried into the receiver and inflate results. Steaming out the apparatus before the first sample and between samples removes that residue and keeps blanks low.
Boric acid with a mixed indicator is common because it traps ammonia without needing a measured excess, then is titrated with standard acid. Alternatively, a measured excess of standard acid is used and back-titrated.
A certified ammonium sulfate or ammonium chloride standard of known nitrogen content is distilled with each batch and the recovery calculated. Values outside the acceptance range indicate leaks, insufficient alkali or a distillation time that is too short.
It is the traditional reference method accepted by pharmacopoeias, food regulations and feed standards, and it is robust across many matrices. Its direct acid digestion step also makes it suitable for referee analysis and for validating faster combustion methods.
Copper sulfate and selenium are the common catalysts, usually with potassium sulfate to raise the boiling point of the acid mixture. Copper is less toxic but slower, while selenium is faster but requires careful handling and disposal.
Reagents, glassware and laboratory air contribute small amounts of nitrogen that would be counted as sample nitrogen. A blank carried through digestion, distillation and titration gives that contribution, which is subtracted from each result.
Related models