Skip to main content
Lab Manufacturers China

Library Preparation Systems

文库制备系统

LPS · Genomics Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 15189, CLSI MM09

Standards referenced

  • ISO 20395
  • ISO 15189
  • CLSI MM09
  • IEC 61010-1
  • ISO 17025

What are Library Preparation Systems?

Library preparation systems convert DNA or RNA into sequencing-ready libraries by fragmenting, end-repairing, ligating adapters and adding indexes, either manually with kits or automatically on a magnetic bead or liquid-handling platform. They are used in genomics, clinical and agrigenomics laboratories before any sequencing run.

5 models of Library Preparation Systems

The 5 models below are current configurations; specifications are confirmed on quotation.

Automated Magnetic Bead Library Preparation System

自动化磁珠法文库制备系统

  • LPS-0001
  • Library Preparation Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Libraries per run:
8, 24 or 96
Protocol time:
approx. 3–6 h
Hands-on set-up time:
approx. 15–30 min
Input DNA:
10 ng–1 µg (kit dependent)
Fragmentation:
Enzymatic, on-deck
Size selection:
Two-step magnetic bead selection

An automated magnetic bead library preparation system performs fragmentation, end repair, adapter ligation, cleanup and size selection on a magnetic platform for 8 to 96 samples per batch. It is the standard choice for laboratories moving routine library construction off the bench.

Request a quote
View details

High-Throughput Library Preparation Platform

高通量文库制备平台

  • LPS-0002
  • Library Preparation Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Libraries per run:
96–384
Libraries per working day:
approx. 384–1,536
Pipetting channels:
96 or 384
Volume range:
1–1,000 µL
Pipetting accuracy:
within ±2% at 200 µL (typical)
Plate formats:
96-well and 384-well

A high-throughput library preparation platform processes 96 to 384 libraries per run on a robotic deck with integrated normalisation, pooling and quality control, serving sequencing cores and service laboratories that need thousands of libraries per week at consistent quality.

Request a quote
View details

Single-Cell Library Preparation System

单细胞文库制备系统

  • LPS-0003
  • Library Preparation Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Cells per run:
500–10,000 per channel
Cell recovery:
50–80% (target)
Multiplet rate:
approx. 1–10% depending on loading
Throughput:
up to 8 channels in parallel (model dependent)
Cell viability required:
over 80% (recommended)
Cell size range:
approx. 5–40 µm (kit dependent)

A single-cell library preparation system partitions thousands of individual cells into droplets or microwells, barcodes each cell's transcripts and builds sequencing libraries that link molecules to their cell of origin. It is used for cell atlas, tumour heterogeneity and immune profiling studies.

Request a quote
View details

Automated Size Selection and Cleanup System

自动化片段筛选与纯化系统

  • LPS-0004
  • Library Preparation Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Samples per run:
8–96
Selection range:
approx. 150 bp–20 kb (method dependent)
Selection precision (bead):
approx. ±15% of cut-off size
Selection precision (gel):
approx. ±5% of cut-off size
Recovery:
approx. 70–90%
Protocol time:
approx. 30–90 min

An automated size selection and cleanup system uses magnetic bead ratios or automated gel electrophoresis to narrow the fragment size distribution of a library, replacing manual bead cleanups and improving reproducibility. It is chosen where insert size consistency drives sequencing performance.

Request a quote
View details

Long-Read Library Preparation System

长读长文库制备系统

  • LPS-0005
  • Library Preparation Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Input DNA:
100 ng–1 µg high molecular weight
Input fragment size:
over 50 kb recommended
Resulting read length:
10 kb–100 kb typical
Protocol time:
approx. 10–60 min (rapid kit) or 2–4 h (ligation kit)
PCR required:
No for native workflows
Barcoding:
Up to 24 samples per run with barcoding kits

A long-read library preparation system converts high molecular weight DNA into libraries with minimal fragmentation and PCR, preserving reads of tens to hundreds of kilobases for nanopore or single-molecule sequencing platforms. It is chosen when read length is the critical parameter.

Request a quote
View details

Compare Library Preparation Systems models

ModelLibraries per runProtocol timeInput DNADimensions (W x D x H)Trackability
Automated Magnetic Bead Library Preparation SystemLPS-00018, 24 or 96approx. 3–6 h10 ng–1 µg (kit dependent)approx. 600 x 500 x 450 mm—
High-Throughput Library Preparation PlatformLPS-000296–384—10 ng–1 µg (kit dependent)approx. 1,500 x 900 x 1,000 mmBarcode and LIMS-linked records with audit trail
Single-Cell Library Preparation SystemLPS-0003———approx. 300 x 350 x 250 mm—
Automated Size Selection and Cleanup SystemLPS-0004—approx. 30–90 min—approx. 400 x 450 x 350 mmBarcode reading with lot and protocol records
Long-Read Library Preparation SystemLPS-0005—approx. 10–60 min (rapid kit) or 2–4 h (ligation kit)100 ng–1 µg high molecular weightapprox. 350 x 400 x 300 mm (automated variant)—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Library Preparation Systems work?

A sequencing library is a pool of DNA fragments flanked by known adapter sequences that the sequencer recognises. Preparation starts with fragmentation by enzymatic digestion, tagmentation or sonication, which produces a defined size distribution. End repair and 3' adenylation make the ends ligatable, and adapters carrying sample indexes are attached by ligation or added during tagmentation. Size selection with magnetic beads or gel-free methods removes fragments outside the target window, and limited-cycle PCR enriches the library and completes the index sequences. Each step is separated by a magnetic bead cleanup that removes enzymes, salts and short fragments. For RNA libraries, reverse transcription and strand-specific second-strand synthesis precede the same workflow. Quality control after preparation measures concentration by fluorometry and fragment size distribution by capillary electrophoresis.

Which Library Preparation Systems variants are available?

  • Automated Magnetic Bead Library Preparation System — An automated magnetic bead library preparation system performs fragmentation, end repair, adapter ligation, cleanup and size selection on a magnetic platform for 8 to 96 samples per batch.
  • High-Throughput Library Preparation Platform — A high-throughput library preparation platform processes 96 to 384 libraries per run on a robotic deck with integrated normalisation, pooling and quality control, serving sequencing cores and service laboratories that need thousands of libraries per week at consistent quality.
  • Single-Cell Library Preparation System — A single-cell library preparation system partitions thousands of individual cells into droplets or microwells, barcodes each cell's transcripts and builds sequencing libraries that link molecules to their cell of origin.
  • Automated Size Selection and Cleanup System — An automated size selection and cleanup system uses magnetic bead ratios or automated gel electrophoresis to narrow the fragment size distribution of a library, replacing manual bead cleanups and improving reproducibility.
  • Long-Read Library Preparation System — A long-read library preparation system converts high molecular weight DNA into libraries with minimal fragmentation and PCR, preserving reads of tens to hundreds of kilobases for nanopore or single-molecule sequencing platforms.

How do I choose the right variant?

Begin with the sequencing platform and the input material. Short-read instruments need libraries with adapters matched to their flow cell chemistry, while long-read instruments need high molecular weight input and minimal PCR. Estimate the input amount per sample, because low-input and single-cell workflows require specialised chemistries. Then choose between manual kits for occasional use, magnetic bead automation for 8–96 samples per batch with walk-away operation, and full liquid-handling platforms for hundreds of samples with integrated normalisation and pooling. Check fragmentation method, index type and multiplexing level, size selection method, required equipment such as magnet racks or thermo mixers, and whether the supplier provides validated protocols for your sample type. Manual library preparation is a common source of batch effects, so automation usually pays back where sample numbers are high.

Where are Library Preparation Systems used?

Library Preparation Systems are specified in whole-genome and exome library construction, RNA sequencing library preparation, single-cell and low-input library workflows, amplicon and targeted panel library preparation and long-read sequencing library preparation.

Which standards and certifications apply?

Work with Library Preparation Systems is commonly governed by ISO 20395, ISO 15189, CLSI MM09, IEC 61010-1 and ISO 17025. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Set up library preparation in a pre-PCR room separated from post-PCR and sequencing areas, and use dedicated pipettes, racks and reagents that never leave the room. Contamination from previous libraries shows up as unexpected index combinations, so include a no-template control in every batch and monitor index hopping between runs. Reagents are sensitive to freeze-thaw cycles, so aliquot enzymes and record lot numbers. Validate each new kit or automation script against a reference sample, checking yield, insert size and library complexity before routine use. Because library yield determines sequencing data quality, keep documentation that links each library to its sample, index, kit lot and operator so results can be traced during audits.

Frequently asked questions about Library Preparation Systems

It converts nucleic acid into sequencer-ready fragments by fragmenting the DNA, repairing and adenylating ends, ligating indexed adapters, selecting a fragment size range and amplifying briefly. Each step is separated by a bead cleanup that removes enzymes and short fragments.

Need help specifying Library Preparation Systems?

Request a quote