Skip to main content
Lab Manufacturers China
Automated Magnetic Bead Library Preparation System — product photo

Automated Magnetic Bead Library Preparation System

自动化磁珠法文库制备系统

  • SKU LPS-0001
  • Library Preparation Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Libraries per run8, 24 or 96
Protocol timeapprox. 3–6 h
Hands-on set-up timeapprox. 15–30 min
Input DNA10 ng–1 µg (kit dependent)
FragmentationEnzymatic, on-deck
Size selectionTwo-step magnetic bead selection
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 15189, CLSI MM09

What is the Automated Magnetic Bead Library Preparation System?

An automated magnetic bead library preparation system performs fragmentation, end repair, adapter ligation, cleanup and size selection on a magnetic platform for 8 to 96 samples per batch. It is the standard choice for laboratories moving routine library construction off the bench.

What is the Automated Magnetic Bead Library Preparation System?

An automated magnetic bead library preparation system performs fragmentation, end repair, adapter ligation, cleanup and size selection on a magnetic platform for 8 to 96 samples per batch. It is the standard choice for laboratories moving routine library construction off the bench.

Overview

The system holds a deep-well plate or strip tubes on a heated block and uses a magnetic head to collect beads during each cleanup, exchanging reagents by pipetting rather than by column. Programs cover enzymatic fragmentation, end repair and adenylation, adapter ligation, two bead-based size selection steps and limited-cycle PCR with an on-deck thermocycler module. Typical protocol time is 3–6 hours for 24–48 samples including hands-on set-up of about 15 minutes. Because volumes and magnetic separation times are fixed by the program, batch-to-batch variation is usually lower than with manual preparation, and the script records which kit lot and protocol version were used. Most systems accept standard magnetic bead chemistries and can be programmed for custom protocols, which keeps consumable costs moderate.

How does it work?

A sequencing library is a pool of DNA fragments flanked by known adapter sequences that the sequencer recognises. Preparation starts with fragmentation by enzymatic digestion, tagmentation or sonication, which produces a defined size distribution. End repair and 3' adenylation make the ends ligatable, and adapters carrying sample indexes are attached by ligation or added during tagmentation. Size selection with magnetic beads or gel-free methods removes fragments outside the target window, and limited-cycle PCR enriches the library and completes the index sequences. Each step is separated by a magnetic bead cleanup that removes enzymes, salts and short fragments. For RNA libraries, reverse transcription and strand-specific second-strand synthesis precede the same workflow. Quality control after preparation measures concentration by fluorometry and fragment size distribution by capillary electrophoresis.

What are the key features?

  • Batch capacity of 8, 24 or 96 libraries per run
  • On-deck heating and magnetic separation for bead cleanups
  • Programmed fragmentation, ligation, size selection and PCR
  • Automated reagent addition with tip and reagent tracking
  • Protocol version and kit lot records for traceability
  • Compatible with standard magnetic bead chemistries

What are the technical specifications?

A typical automated magnetic bead library preparation system configuration offers libraries per run of 8, 24 or 96, protocol time of approx. 3–6 h, hands-on set-up time of approx. 15–30 min, input DNA of 10 ng–1 µg (kit dependent), fragmentation of Enzymatic, on-deck and size selection of Two-step magnetic bead selection. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Magnetic Bead Library Preparation System is used in routine whole-genome and exome libraries, RNA sequencing library construction, amplicon and targeted panel libraries and diagnostic laboratory sample batches. Across the wider Library Preparation Systems class, laboratories also deploy it for whole-genome and exome library construction, RNA sequencing library preparation and single-cell and low-input library workflows.

Which standards and certifications apply?

Relevant standards and methods include ISO 20395, ISO 15189, CLSI MM09, IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Set up library preparation in a pre-PCR room separated from post-PCR and sequencing areas, and use dedicated pipettes, racks and reagents that never leave the room. Contamination from previous libraries shows up as unexpected index combinations, so include a no-template control in every batch and monitor index hopping between runs. Reagents are sensitive to freeze-thaw cycles, so aliquot enzymes and record lot numbers. Validate each new kit or automation script against a reference sample, checking yield, insert size and library complexity before routine use. Because library yield determines sequencing data quality, keep documentation that links each library to its sample, index, kit lot and operator so results can be traced during audits.

How do I select the right Automated Magnetic Bead Library Preparation System?

Select an automated magnetic bead system when library numbers justify moving off manual preparation and you want consistent insert sizes and yields. Specify batch size, supported kits, fragmentation method, size selection options, protocol scripting freedom and how kit lots and protocol versions are recorded.

How does it compare with other Library Preparation Systems variants?

Begin with the sequencing platform and the input material. Short-read instruments need libraries with adapters matched to their flow cell chemistry, while long-read instruments need high molecular weight input and minimal PCR. Estimate the input amount per sample, because low-input and single-cell workflows require specialised chemistries. Then choose between manual kits for occasional use, magnetic bead automation for 8–96 samples per batch with walk-away operation, and full liquid-handling platforms for hundreds of samples with integrated normalisation and pooling. Check fragmentation method, index type and multiplexing level, size selection method, required equipment such as magnet racks or thermo mixers, and whether the supplier provides validated protocols for your sample type. Manual library preparation is a common source of batch effects, so automation usually pays back where sample numbers are high.

Full specifications

Full specifications
Libraries per run8, 24 or 96
Protocol timeapprox. 3–6 h
Hands-on set-up timeapprox. 15–30 min
Input DNA10 ng–1 µg (kit dependent)
FragmentationEnzymatic, on-deck
Size selectionTwo-step magnetic bead selection
Reaction volume20–100 µL
Heating rangeambient to 95 °C
Index supportSingle and dual indexing kits
Dimensions (W x D x H)approx. 600 x 500 x 450 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Routine whole-genome and exome libraries
  • RNA sequencing library construction
  • Amplicon and targeted panel libraries
  • Diagnostic laboratory sample batches

Key features

  • Batch capacity of 8, 24 or 96 libraries per run
  • On-deck heating and magnetic separation for bead cleanups
  • Programmed fragmentation, ligation, size selection and PCR
  • Automated reagent addition with tip and reagent tracking
  • Protocol version and kit lot records for traceability
  • Compatible with standard magnetic bead chemistries

Frequently asked questions about Automated Magnetic Bead Library Preparation System

An automated run takes about 3–6 hours for 24–48 libraries including PCR, with 15–30 minutes of hands-on set-up. Manual preparation of the same number takes longer and requires continuous attention between bead cleanups.

SNP Array Genotyping System — product photo

SNP Array Genotyping System

SNP 芯片基因分型系统

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Automated Magnetic Bead Library Preparation System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote