Clean Benches

洁净工作台(洁净室设备)

CLB · Cleanroom Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), ISO 14644-4 (design and construction)

Standards referenced

  • ISO 14644-1 (cleanroom classification)
  • ISO 14644-3 (test methods)
  • ISO 14644-4 (design and construction)
  • IEST-RP-CC002 (unidirectional flow devices)
  • JG/T 292 (clean bench)
  • GB/T 25915.1
  • EN 1822 (HEPA and ULPA filters)

What are Clean Benches?

In cleanroom facilities, clean benches are HEPA-filtered workstations installed inside classified rooms to give ISO 5 local protection for assembly, inspection and handling of particle-sensitive products. Electronics, optics, medical-device and pharmaceutical operations use them as a point-of-use upgrade over the room class.

5 models of Clean Benches

The 5 models below are current configurations; specifications are confirmed on quotation.

Vertical Laminar Flow Clean Bench for Cleanroom Assembly

洁净室装配用垂直流洁净工作台

  • CLB-0001
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Airflow direction:
Vertical (downward)
Air velocity:
0.3–0.45 m/s
Cleanliness class:
ISO 5 (Class 100)
Filter grade:
H14 HEPA, ≥ 99.995 % at MPPS
Work-zone width:
900 / 1200 / 1500 mm
Work height:
750–850 mm

A vertical laminar flow clean bench supplies HEPA-filtered air downward from the top of the work zone. In cleanrooms it is used for component assembly and handling where parts are worked on from above.

Request a quote
View details

Horizontal Laminar Flow Clean Bench for Cleanroom Inspection

洁净室检查用水平流洁净工作台

  • CLB-0002
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Airflow direction:
Horizontal (rear to front)
Air velocity:
0.3–0.5 m/s
Cleanliness class:
ISO 5 (Class 100)
Filter grade:
H14 HEPA
Work-zone width:
900 / 1200 / 1500 mm
Work-zone depth:
600–800 mm

A horizontal laminar flow clean bench delivers HEPA-filtered air from the rear wall toward the operator across the work surface. It suits inspection, assembly and handling of larger items in cleanrooms. It is typically chosen for open-front handling.

Request a quote
View details

ULPA Clean Bench for Semiconductor and Optics

半导体和光学用 ULPA 洁净工作台

  • CLB-0003
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Filter grade:
U15 ULPA, ≥ 99.9995 %
Cleanliness class:
ISO 4–5
Air velocity:
0.3–0.4 m/s
Airflow direction:
Vertical or horizontal
Work-zone width:
900–1500 mm
Fan type:
EC, variable speed

A ULPA clean bench uses an ultra-low penetration air filter rated at 99.999 % efficiency to give ISO 4–5 conditions. It is selected for semiconductor, wafer, mask and precision optics handling where sub-micron particles matter.

Request a quote
View details

ESD-Safe Clean Bench

防静电洁净工作台

  • CLB-0004
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Surface resistance:
106–109 ohm
Residual voltage:
≤ ±50 V
Cleanliness class:
ISO 5
Air velocity:
0.3–0.45 m/s
Filter grade:
H14 HEPA
Work-zone width:
900–1500 mm

An ESD-safe clean bench combines laminar HEPA airflow with static-dissipative surfaces, ionization and grounding. It protects static-sensitive components such as ICs, PCBs and sensors while keeping particles away. It is a niche choice with real cost implications.

Request a quote
View details

Mobile Clean Bench for Cleanroom Use

洁净室用移动式洁净工作台

  • CLB-0005
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Mobility:
4 locking casters
Cleanliness class:
ISO 5 at rest
Air velocity:
0.3–0.45 m/s
Filter grade:
H14 HEPA
Width:
800–1200 mm
Weight:
80–150 kg

A mobile clean bench is a clean bench mounted on locking casters so it can be moved between stations within a cleanroom. It provides flexible ISO 5 local protection without fixed installation.

Request a quote
View details

Compare Clean Benches models

ModelAirflow directionAir velocityCleanliness classFilter gradeWork-zone width
Vertical Laminar Flow Clean Bench for Cleanroom AssemblyCLB-0001Vertical (downward)0.3–0.45 m/sISO 5 (Class 100)H14 HEPA, ≥ 99.995 % at MPPS900 / 1200 / 1500 mm
Horizontal Laminar Flow Clean Bench for Cleanroom InspectionCLB-0002Horizontal (rear to front)0.3–0.5 m/sISO 5 (Class 100)H14 HEPA900 / 1200 / 1500 mm
ULPA Clean Bench for Semiconductor and OpticsCLB-0003Vertical or horizontal0.3–0.4 m/sISO 4–5U15 ULPA, ≥ 99.9995 %900–1500 mm
ESD-Safe Clean BenchCLB-0004—0.3–0.45 m/sISO 5H14 HEPA900–1500 mm
Mobile Clean Bench for Cleanroom UseCLB-0005—0.3–0.45 m/sISO 5 at restH14 HEPA—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Clean Benches work?

A cleanroom clean bench draws air from the room through a prefilter, pressurizes it in a plenum and forces it through a HEPA or ULPA filter so that unidirectional (laminar) air flows over the work surface at 0.3–0.5 m/s. In a horizontal design the air passes from the rear toward the operator, while in a vertical design it descends from the ceiling of the work zone. The moving air sweeps particles generated by operators and products away from the work area, maintaining ISO Class 5 (Class 100) air at the working height. Because the air exits into the room, these benches protect the product, not the operator. Stainless steel or powder-coated steel work surfaces, fluorescent LED lighting, and an airflow controller complete the unit. For cleanrooms, benches often use low-particle materials and sealed cable penetrations.

Which Clean Benches variants are available?

  • Vertical Laminar Flow Clean Bench for Cleanroom Assembly — A vertical laminar flow clean bench supplies HEPA-filtered air downward from the top of the work zone.
  • Horizontal Laminar Flow Clean Bench for Cleanroom Inspection — A horizontal laminar flow clean bench delivers HEPA-filtered air from the rear wall toward the operator across the work surface.
  • ULPA Clean Bench for Semiconductor and Optics — A ULPA clean bench uses an ultra-low penetration air filter rated at 99.999 % efficiency to give ISO 4–5 conditions.
  • ESD-Safe Clean Bench — An ESD-safe clean bench combines laminar HEPA airflow with static-dissipative surfaces, ionization and grounding.
  • Mobile Clean Bench for Cleanroom Use — A mobile clean bench is a clean bench mounted on locking casters so it can be moved between stations within a cleanroom.

How do I choose the right variant?

Choose by the direction of airflow, the size of the work area and the product being handled. Vertical flow suits assembly of components where operators work over the product, while horizontal flow suits inspection of larger items. Check the work-zone width, commonly 900–1800 mm, the filter grade, H14 HEPA or ULPA U15 for critical semiconductor work, and the air velocity control. Consider noise, which should remain under 65 dB(A), vibration, and ESD-safe surfaces for electronics. Stainless steel tops suit pharmaceutical use, while ESD-rated tops suit electronics. Decide whether a mobile stand, a wall-hung option or built-in lighting is required. Benches for chemicals or biologicals require fume or biosafety protection instead, not a clean bench.

Where are Clean Benches used?

Clean Benches are specified in electronics assembly, optical component inspection, medical-device assembly, pharmaceutical sample handling and semiconductor packaging.

Which standards and certifications apply?

Work with Clean Benches is commonly governed by ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), ISO 14644-4 (design and construction), IEST-RP-CC002 (unidirectional flow devices), JG/T 292 (clean bench), GB/T 25915.1 and EN 1822 (HEPA and ULPA filters). Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Place the bench away from doors and supply diffusers, since room drafts above 0.1 m/s can disturb the laminar flow. Commission with a filter leak test, airflow velocity survey and particle count to ISO 14644-3. Replace prefilters every 3–6 months and HEPA filters when face velocity cannot be restored at maximum fan speed, typically every 3–5 years. Wipe surfaces with isopropanol or a compatible disinfectant, working from clean to dirty. Because benches recirculate room air, they must not be used with hazardous chemicals, pathogens or cytotoxics. Record airflow and particle checks in the cleanroom log for regulatory audits.

Frequently asked questions about Clean Benches

A cleanroom clean bench is a HEPA-filtered workstation that directs laminar air over the work surface at 0.3–0.5 m/s to give ISO 5 conditions. It protects the product but not the operator, so it is not suitable for hazardous materials.

Need help specifying Clean Benches?

Request a quote