X-Ray Reflectometry Diffractometer

X 射线反射率衍射仪

  • SKU XRA-0004
  • X-Ray Diffractometers
  • CE (to be confirmed)
  • Radiation safety enclosure (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Angular range0–10°
Thickness range0.3 nm to 500 nm
Roughness resolution0.1–5 nm
Angular stepdown to 0.001°
Detectorscintillation or area detector
X-ray tube power1–3 kW
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM E1426 Determining the effective elastic parameter for X-ray diffraction measurements of residual stress, USP <941> X-Ray Diffraction

What is the X-Ray Reflectometry Diffractometer?

An X-ray reflectometry diffractometer measures specular reflection at very low angles to profile thin layers. It is chosen for routine film thickness, density and interface roughness in deposited single and multilayer stacks.

What is the X-Ray Reflectometry Diffractometer?

An X-ray reflectometry diffractometer measures specular reflection at very low angles to profile thin layers. It is chosen for routine film thickness, density and interface roughness in deposited single and multilayer stacks.

Overview

In X-ray reflectometry the beam strikes a flat sample at grazing angles and the intensity of the specularly reflected beam is recorded as the angle increases. Above the critical angle the reflectivity falls rapidly and oscillates; the oscillation period gives layer thickness, the critical angle gives electron density, and the decay and fringe contrast give interface roughness. The technique resolves layers from a few angstroms to a few hundred nanometres, which complements diffraction and electron microscopy, and it is non-destructive. Samples must be very flat and clean, because surface roughness broadens the curve and reduces fringe contrast. Alignment, beam divergence and background control determine the accessible thickness and roughness range, and data are fitted with optical models of the layer stack.

How does it work?

X-rays scatter from the electron density of a material. In a crystal, scattering from periodic lattice planes interferes constructively at angles given by Bragg's law, producing diffraction peaks. A diffractometer positions the sample and detector with high angular precision and records intensity versus angle or versus a two-dimensional detector image. Single-crystal instruments determine atomic structure from the full set of reflections, while powder and thin-film instruments analyze phase mixtures, preferred orientation and layer structure. Peak positions give lattice parameters and strain, peak widths relate to crystallite size and microstrain, and low-angle scattering reveals nanoscale features. The choice of optics, monochromator, detector and sample stage determines which measurements are possible, and instrument alignment with certified standards underpins accuracy.

What are the key features?

  • Specular reflection at grazing angles
  • Layer thickness from fringe period
  • Electron density from the critical angle
  • Interface roughness from decay and contrast
  • Non-destructive measurement of layer stacks
  • Optical model fitting of the reflectivity curve

What are the technical specifications?

A typical x-ray reflectometry diffractometer configuration offers angular range of 0–10°, thickness range of 0.3 nm to 500 nm, roughness resolution of 0.1–5 nm, angular step of down to 0.001°, detector of scintillation or area detector and X-ray tube power of 1–3 kW. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The X-Ray Reflectometry Diffractometer is used in single and multilayer film thickness, interface roughness and interdiffusion, polymer and organic thin films and semiconductor and optical coating quality. Across the wider X-Ray Diffractometers class, laboratories also deploy it for single-crystal structure determination, thin-film thickness, texture and phase analysis and residual stress in welds, coatings and machined parts.

Which standards and certifications apply?

Relevant standards and methods include ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM E1426 Determining the effective elastic parameter for X-ray diffraction measurements of residual stress, USP <941> X-Ray Diffraction, ISO 20203 Carbonaceous materials — XRD of calcined coke, ISO/IEC 17025 and IEC 61010-2-091. Certification candidates for this model are CE, Radiation safety enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

These are regulated radiation devices requiring shielding, interlocks, radiation surveys and trained operators. Single crystals must be mounted and centered precisely, and low-temperature or humidity devices often protect them. Thin films and wafers need flat mounting and careful alignment to the beam, and reflectometry requires very low background and precise angular steps. Residual stress methods need defined measurement directions and elastic constants. Small-angle systems require long evacuated paths and clean beam stops. Alignment, angular calibration and detector linearity are verified with standards, and X-ray tubes, goniometer motors and area detectors are wear items. Sample preparation and measurement conditions should be recorded for traceability.

How do I select the right X-Ray Reflectometry Diffractometer?

Select X-ray reflectometry when layer thickness, density and interface roughness below about half a micrometre must be measured non-destructively and the sample is flat. Specify the layer stack, thickness range and required roughness resolution. Confirm that the instrument reaches low enough angles and that sample flatness meets the requirement.

How does it compare with other X-Ray Diffractometers variants?

Select a diffractometer configuration by the structural question. Single-crystal systems with four-circle or kappa goniometers and area detectors determine atomic structures from small crystals. Thin-film instruments with grazing-incidence optics and parallel beams measure layer thickness, texture and phase in coatings. Reflectometry configurations measure electron density profiles, interface roughness and layer thickness at very low angles. Residual stress instruments use side-inclination or psi geometry with precise sample tilting to measure strain in metals and ceramics. Small-angle scattering systems with long camera lengths resolve nanometre-scale particles, pores and lamellae. Confirm the angular range and resolution, sample environment, detector type and software for your application, and verify that the instrument can follow any required standard method.

Full specifications

Full specifications
Angular range0–10°
Thickness range0.3 nm to 500 nm
Roughness resolution0.1–5 nm
Angular stepdown to 0.001°
Detectorscintillation or area detector
X-ray tube power1–3 kW
Opticsparallel beam or monochromator
Sample flatnessbetter than 1 nm RMS
Sample sizeup to 200 mm wafers
InterfaceEthernet

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Single and multilayer film thickness
  • Interface roughness and interdiffusion
  • Polymer and organic thin films
  • Semiconductor and optical coating quality

Key features

  • Specular reflection at grazing angles
  • Layer thickness from fringe period
  • Electron density from the critical angle
  • Interface roughness from decay and contrast
  • Non-destructive measurement of layer stacks
  • Optical model fitting of the reflectivity curve

Frequently asked questions about X-Ray Reflectometry Diffractometer

Reflectometry resolves layers from about 0.3 to 500 nanometres. Below this range the fringes are too few to fit, and above it the angular spacing becomes too small to resolve. Thicker films are usually measured by cross-sectional electron microscopy or by diffraction methods.

Request a quotation for the X-Ray Reflectometry Diffractometer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote