

Single-Crystal X-Ray Diffractometer
单晶 X 射线衍射仪
- SKU XRA-0001
- X-Ray Diffractometers
- CE (to be confirmed)
- Radiation safety enclosure (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Crystal size | 50–300 µm typical |
|---|---|
| 2-theta range | up to 160° |
| Goniometer | kappa or four-circle |
| Detector | large area, photon counting |
| X-ray source | sealed tube or microfocus |
| Temperature range | 80–400 K with device |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM E1426 Determining the effective elastic parameter for X-ray diffraction measurements of residual stress, USP <941> X-Ray Diffraction
What is the Single-Crystal X-Ray Diffractometer?
A single-crystal X-ray diffractometer measures individual reflections from one crystal to solve its complete full atomic structure. It is chosen for chemical crystallography, new compounds and absolute configuration determination in structural research.
What is the Single-Crystal X-Ray Diffractometer?
A single-crystal X-ray diffractometer measures individual reflections from one crystal to solve its complete full atomic structure. It is chosen for chemical crystallography, new compounds and absolute configuration determination in structural research.
Overview
The instrument combines a fine-focus X-ray source with monochromating optics, a kappa or four-circle goniometer and a large area detector. A single crystal, often only 50 to 300 micrometres across, is mounted on a fiber or loop and centered in the beam. The goniometer rotates the crystal through many orientations, and the detector records hundreds to thousands of reflections, which software indexes and refines into a structural model with atomic coordinates, bond lengths, angles and thermal parameters. Modern detectors and software allow structures of small molecules to be solved in hours, and low-temperature devices reduce thermal motion and protect unstable crystals. Careful crystal selection and mounting, correct absorption correction and high data completeness are essential for reliable refinement.
How does it work?
X-rays scatter from the electron density of a material. In a crystal, scattering from periodic lattice planes interferes constructively at angles given by Bragg's law, producing diffraction peaks. A diffractometer positions the sample and detector with high angular precision and records intensity versus angle or versus a two-dimensional detector image. Single-crystal instruments determine atomic structure from the full set of reflections, while powder and thin-film instruments analyze phase mixtures, preferred orientation and layer structure. Peak positions give lattice parameters and strain, peak widths relate to crystallite size and microstrain, and low-angle scattering reveals nanoscale features. The choice of optics, monochromator, detector and sample stage determines which measurements are possible, and instrument alignment with certified standards underpins accuracy.
What are the key features?
- Fine-focus source with monochromating optics
- Kappa or four-circle precision goniometer
- Large area detector for fast data collection
- Crystal mounting on fiber or loop
- Low-temperature device for unstable crystals
- Software for indexing, absorption correction and refinement
What are the technical specifications?
A typical single-crystal x-ray diffractometer configuration offers crystal size of 50–300 µm typical, 2-theta range of up to 160°, goniometer of kappa or four-circle, detector of large area, photon counting, X-ray source of sealed tube or microfocus and temperature range of 80–400 K with device. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Single-Crystal X-Ray Diffractometer is used in new compound structure determination, absolute configuration of chiral molecules, polymorph and salt structure studies and mineral and inorganic crystal structure research. Across the wider X-Ray Diffractometers class, laboratories also deploy it for single-crystal structure determination, thin-film thickness, texture and phase analysis and residual stress in welds, coatings and machined parts.
Which standards and certifications apply?
Relevant standards and methods include ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM E1426 Determining the effective elastic parameter for X-ray diffraction measurements of residual stress, USP <941> X-Ray Diffraction, ISO 20203 Carbonaceous materials — XRD of calcined coke, ISO/IEC 17025 and IEC 61010-2-091. Certification candidates for this model are CE, Radiation safety enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
These are regulated radiation devices requiring shielding, interlocks, radiation surveys and trained operators. Single crystals must be mounted and centered precisely, and low-temperature or humidity devices often protect them. Thin films and wafers need flat mounting and careful alignment to the beam, and reflectometry requires very low background and precise angular steps. Residual stress methods need defined measurement directions and elastic constants. Small-angle systems require long evacuated paths and clean beam stops. Alignment, angular calibration and detector linearity are verified with standards, and X-ray tubes, goniometer motors and area detectors are wear items. Sample preparation and measurement conditions should be recorded for traceability.
How do I select the right Single-Crystal X-Ray Diffractometer?
Select a single-crystal diffractometer when complete atomic structures or absolute configurations are required and suitable crystals can be grown. Specify the crystal size, element range and whether low-temperature or high-pressure devices are needed. Confirm detector sensitivity and software for the structures you plan to solve.
How does it compare with other X-Ray Diffractometers variants?
Select a diffractometer configuration by the structural question. Single-crystal systems with four-circle or kappa goniometers and area detectors determine atomic structures from small crystals. Thin-film instruments with grazing-incidence optics and parallel beams measure layer thickness, texture and phase in coatings. Reflectometry configurations measure electron density profiles, interface roughness and layer thickness at very low angles. Residual stress instruments use side-inclination or psi geometry with precise sample tilting to measure strain in metals and ceramics. Small-angle scattering systems with long camera lengths resolve nanometre-scale particles, pores and lamellae. Confirm the angular range and resolution, sample environment, detector type and software for your application, and verify that the instrument can follow any required standard method.
Full specifications
| Crystal size | 50–300 µm typical |
|---|---|
| 2-theta range | up to 160° |
| Goniometer | kappa or four-circle |
| Detector | large area, photon counting |
| X-ray source | sealed tube or microfocus |
| Temperature range | 80–400 K with device |
| Angular accuracy | ±0.01° |
| Data collection time | 1–24 h per crystal |
| Radiation | Mo or Cu K-alpha |
| Enclosure | shielded with interlocks |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- New compound structure determination
- Absolute configuration of chiral molecules
- Polymorph and salt structure studies
- Mineral and inorganic crystal structure research
Key features
- Fine-focus source with monochromating optics
- Kappa or four-circle precision goniometer
- Large area detector for fast data collection
- Crystal mounting on fiber or loop
- Low-temperature device for unstable crystals
- Software for indexing, absorption correction and refinement
Frequently asked questions about Single-Crystal X-Ray Diffractometer
Typical crystals are 50 to 300 micrometres across, though modern detectors and microfocus sources can measure crystals down to about 10 micrometres. Crystals should be single, well-formed and free of cracks. Larger crystals may need absorption correction, and smaller ones need longer measurement times.
Cooling to about 100 kelvin reduces atomic thermal motion, sharpening diffraction data, and protects crystals that lose solvent or decompose at room temperature. It also improves the accuracy of hydrogen atom positions in some cases. A cold stream or cryoloop system keeps the crystal stable during long collection.
Data quality depends on crystal quality, data completeness, redundancy, the resolution limit and the signal-to-noise ratio of the reflections. Software evaluates these parameters and flags problems. Good mounting, correct absorption correction and sufficient exposure time are essential for a reliable structure refinement.
Single-crystal diffraction measures individual reflections from one crystal, giving enough data to solve the full atomic structure, including bond lengths and angles. Powder diffraction measures the overlapping reflections from many randomly oriented crystallites, which identifies and quantifies phases but cannot alone determine a complete atomic structure.
The sample is tilted to several angles and the shift of a chosen diffraction peak is measured at each tilt. Lattice strain is calculated from the peak shift, and stress follows from the strain and the material elastic constants. Methods follow standards such as ASTM E1426 and require defined measurement directions.
At very shallow incidence angles the X-ray beam probes only the near-surface region of a thin film or coating, which reduces signal from the substrate. This allows phase identification, texture and depth profiling of layers only nanometres to micrometres thick, as used for semiconductors, optical coatings and corrosion films.




