Interfacial Tension Tester for Insulating Oil
绝缘油界面张力测定仪
- SKU TOT-0005
- Transformer Oil Testing
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0–100 mN/m |
|---|---|
| Resolution | 0.01 mN/m |
| Accuracy | ± 0.1 mN/m |
| Ring circumference | ≈ 6.0 cm (typical) |
| Ring lift speed | ≈ 0.3 mm/s |
| Sample volume | ≈ 40 mL oil + 40 mL water |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 60156, ASTM D1816, ASTM D877
What is the Interfacial Tension Tester for Insulating Oil?
An interfacial tension tester measures the force needed to pull a platinum ring through the oil-water interface, reporting tension in mN/m. A falling value indicates dissolved polar aging products and sludge precursors in transformer oil, making it a sensitive early ageing indicator.
What is the Interfacial Tension Tester for Insulating Oil?
An interfacial tension tester measures the force needed to pull a platinum ring through the oil-water interface, reporting tension in mN/m. A falling value indicates dissolved polar aging products and sludge precursors in transformer oil, making it a sensitive early ageing indicator.
Overview
A du Noüy ring tensiometer lowers a platinum-iridium ring into distilled water at 25 degrees Celsius, layers the oil sample on top, and then pulls the ring upward through the interface. A torsion balance or electronic force sensor records the maximum force just before the lamella breaks. After correction for ring dimensions, density difference and the Harkins-Jordan factor, the result is the interfacial tension in mN/m. New transformer oil typically gives 40 to 50 mN/m, and values below about 25 mN/m indicate significant oxidation products. The test is sensitive to contamination and timing: the ring must be flame-cleaned, and measurement should occur within 30 seconds of forming the interface as specified in ASTM D971.
How does it work?
Insulating oil must resist electrical stress, remove heat and protect paper insulation, so testing targets each of these functions. Dielectric breakdown voltage is measured by increasing AC voltage at a fixed rate between standard electrodes in a stirred test cell until a discharge occurs. Dissolved gas analysis extracts gases from oil by headspace, vacuum or stripping and separates hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide and carbon dioxide by gas chromatography with thermal conductivity and flame ionization detectors. Karl Fischer coulometry titrates water electrochemically. Dissipation factor and resistivity are measured in a three-terminal cell heated to 90 degrees Celsius. Interfacial tension uses a platinum ring that is pulled through the oil-water interface, and the pulling force gives the tension in mN/m.
What are the key features?
- Platinum-iridium du Noüy ring with electronic force sensor
- Automatic lift mechanism with constant 0.3 mm/s speed
- Built-in density-difference and Harkins-Jordan correction
- Thermostatic vessel holder for 25 °C measurement
- Digital display with data storage and USB export
What are the technical specifications?
A typical interfacial tension tester for insulating oil configuration offers measuring range of 0–100 mN/m, resolution of 0.01 mN/m, accuracy of ± 0.1 mN/m, ring circumference of ≈ 6.0 cm (typical), ring lift speed of ≈ 0.3 mm/s and sample volume of ≈ 40 mL oil + 40 mL water. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Interfacial Tension Tester for Insulating Oil is used in transformer oil aging assessment, oil reclamation monitoring and acceptance testing of new insulating oil. Across the wider Transformer Oil Testing class, laboratories also deploy it for transformer acceptance and commissioning tests, routine insulating oil monitoring for utilities and fault diagnosis by dissolved gas analysis.
Which standards and certifications apply?
Relevant standards and methods include IEC 60156, ASTM D1816, ASTM D877, IEC 60599, ASTM D3612, IEC 60814, IEC 60247, ASTM D971 and GB/T 507. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sampling is as critical as analysis: use clean, dry glass syringes or sampling bottles, avoid air exposure for dissolved gas samples and record oil temperature. Test cells and electrodes must be cleaned and rinsed with the test oil, and gap distance verified with a gauge. High-voltage testers need grounded benches, interlocked lids and periodic verification of voltage and rate of rise. Gas chromatographs require carrier gas purity, column conditioning and calibration with certified gas mixtures. Karl Fischer reagents are replaced per usage. Follow facility safety rules, and dispose of oil and halogenated waste according to regulations.
How do I select the right Interfacial Tension Tester for Insulating Oil?
Select an interfacial tension tester when your program needs a sensitive indicator of polar aging products, especially for in-service transformer oil in which sludge formation is a concern. Specify ring type, resolution, thermostat accommodation and compliance with ASTM D971 or ISO 6295, and note that it does not replace dielectric or moisture testing.
How does it compare with other Transformer Oil Testing variants?
Choose equipment by the decisions it supports. A breakdown voltage tester is the minimum for acceptance and routine screening; select the test voltage class (80 kV for most service oil, 100 kV or higher for new oil and EHV equipment) and the electrode type that your standard requires, VDE or spherical for IEC 60156, or ASTM D1816 or D877 types. Dissolved gas analysis is the key diagnostic for fault detection and suits utilities with many assets. Coulometric Karl Fischer is needed because moisture strongly affects paper insulation life. Tan delta and resistivity testers help detect polar contaminants and aging, while IFT indicates sludge precursors. Also check sample volume, automation level, test-cell cleaning, data logging and safe high-voltage interlocks.
Full specifications
| Measuring range | 0–100 mN/m |
|---|---|
| Resolution | 0.01 mN/m |
| Accuracy | ± 0.1 mN/m |
| Ring circumference | ≈ 6.0 cm (typical) |
| Ring lift speed | ≈ 0.3 mm/s |
| Sample volume | ≈ 40 mL oil + 40 mL water |
| Test temperature | 25 ± 1 °C |
| Vessel diameter | ≈ 45–55 mm |
| Power supply | 220 V AC, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Transformer oil aging assessment
- Oil reclamation monitoring
- Acceptance testing of new insulating oil
Key features
- Platinum-iridium du Noüy ring with electronic force sensor
- Automatic lift mechanism with constant 0.3 mm/s speed
- Built-in density-difference and Harkins-Jordan correction
- Thermostatic vessel holder for 25 °C measurement
- Digital display with data storage and USB export
Frequently asked questions about Interfacial Tension Tester for Insulating Oil
Interfacial tension drops as polar oxidation products dissolve in oil and lower the tension against water. It is a sensitive early indicator of aging and sludge precursors, often falling before acidity or color change becomes obvious.
Traces of oil or surfactant on the ring change the contact angle and bias results. Rinsing with solvent and then annealing the platinum ring in a flame removes residues and restores a fully wetted surface.
The du Noüy ring method is the classic standard method for insulating oil in ASTM D971. Wilhelmy plate and drop-volume tensiometers are also used in research, but oil specifications generally reference the ring procedure.
Standard tests include dielectric breakdown voltage, water content, acidity, dissipation factor, resistivity, interfacial tension and dissolved gas analysis. Together they assess insulating strength, contamination, aging and incipient faults, with frequency depending on transformer voltage class and criticality.
Dissolved gas analysis extracts gases from transformer oil and measures hydrogen, hydrocarbons and carbon oxides by gas chromatography. Gas ratios and concentrations indicate fault types such as partial discharge, overheating or arcing, using interpretation methods in IEC 60599 or IEEE C57.104.
Water lowers dielectric strength and accelerates cellulose degradation, shortening transformer life. Because most water resides in the paper insulation, oil moisture is interpreted together with temperature, using equilibrium curves to estimate paper moisture content.
Related models


Gas Chromatograph for Dissolved Gas Analysis in Transformer Oil
变压器油溶解气体分析气相色谱仪
- CE (to be confirmed)
- +1


Dielectric Loss Tangent and Volume Resistivity Tester for Insulating Oil
绝缘油介质损耗及体积电阻率测试仪
- CE (to be confirmed)
- +1