Linear MALDI-TOF Mass Spectrometer for Microbial Identification
用于微生物鉴定的线性 MALDI-TOF 质谱仪
- CE (to be confirmed)
- +3
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

MALDI-TOF/TOF 串联质谱仪
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| MS mass range | m/z 500–30000 (reflectron) |
|---|---|
| MS/MS precursor range | m/z 700–4000 |
| MS resolution (m/z 2500) | ≥ 15000 FWHM |
| MS/MS resolution | ≥ 1500 FWHM (typical) |
| Precursor selection window | ~1–3 u |
| Mass accuracy, MS (internal) | ≤ 5 ppm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D7134, ISO 11260, ISO/TS 16940
A MALDI-TOF/TOF uses two time-of-flight sections separated by a collision or fragmentation region, selecting a precursor ion and recording its product ions. It provides de novo peptide sequencing, post-translational modification mapping and structural confirmation of polymers and glycans.
A MALDI-TOF/TOF uses two time-of-flight sections separated by a collision or fragmentation region, selecting a precursor ion and recording its product ions. It provides de novo peptide sequencing, post-translational modification mapping and structural confirmation of polymers and glycans.
In a MALDI-TOF/TOF, ions generated by the laser travel through the first TOF section, where a timed ion gate selects a narrow precursor window of 1 to 3 u. The precursor then enters a collision cell with helium or air for high-energy collision-induced dissociation at 1 to 2 keV, or undergoes laser-induced dissociation. Product ions are reaccelerated and analyzed in a second TOF section with a reflectron. Because of high-energy CID, fragment spectra include immonium ions, side-chain fragments and w-type ions that help distinguish leucine from isoleucine. Resolution in MS mode is 15000 to 25000, and MS/MS resolution is typically 1000 to 4000. Laser repetition rates of 1 to 2 kHz accelerate data collection. It supports automated workflows in which MS spectra trigger selection of precursor peaks for MS/MS and database searching, for instance in protein identification after gel electrophoresis.
In a time-of-flight mass spectrometer, ions are given the same kinetic energy by an accelerating potential of several hundred volts to 20 kV and then drift through a field-free tube. Flight time scales with the square root of m/z, so the detector, a microchannel plate or fast electron multiplier, records ions in order of mass. Resolution depends on flight path length and on correcting initial energy spread. A reflectron, an ion mirror, extends the path and refocuses ions of equal mass but different energies, raising resolution from about 1000 to 20000 or more. MALDI sources pulse ions naturally, while orthogonal acceleration converts continuous ESI or ICP beams into pulses. Time-to-digital converters or fast digitizers at gigahertz rates record the signals.
A typical maldi-tof/tof tandem mass spectrometer configuration offers MS mass range of m/z 500–30000 (reflectron), MS/MS precursor range of m/z 700–4000, MS resolution (m/z 2500) of ≥ 15000 FWHM, MS/MS resolution of ≥ 1500 FWHM (typical), precursor selection window of ~1–3 u and mass accuracy, MS (internal) of ≤ 5 ppm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The MALDI-TOF/TOF Tandem Mass Spectrometer is used in peptide sequencing and protein identification, phosphorylation and glycosylation site mapping, structural confirmation of synthetic polymers, oligosaccharide and glycan analysis and bacterial biomarker and toxin confirmation. Across the wider TOF-MS class, laboratories also deploy it for microbial identification in clinical microbiology, intact protein and peptide mass analysis and synthetic polymer molecular weight distribution.
Relevant standards and methods include ASTM D7134, ISO 11260, ISO/TS 16940, USP <1052> Biotechnology-Derived Articles, ASTM E2933, ISO 15189, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
TOF instruments are sensitive to temperature changes, because drift-tube expansion shifts flight time, so install them in a room stable within ±1 to 2 °C and away from drafts. Calibrate frequently with standards or internal lock mass to sustain mass accuracy below 5 ppm. MALDI systems require matrix preparation, such as alpha-cyano-4-hydroxycinnamic acid or sinapinic acid, and careful target plate cleaning. Detector microchannel plates degrade over time, so monitor gain and plan replacement, usually after several years. Keep the vacuum system leak tight, with analyzer pressure below 10^-6 mbar. Regulated laboratories, particularly those using MALDI for clinical microbiology, should confirm validated databases and software supporting audit trail and access control.
Select MALDI-TOF/TOF when you need sequence or structural information from selected precursors, for example after 2D-gel spots or separated fractions. For high-throughput proteomics, LC-MS/MS is usually more productive. In an RFQ, specify MS and MS/MS resolution, precursor window, collision energy, laser rate and database search software.
Select by ionization source and required resolving power. MALDI-TOF suits intact proteins, polymers and microbial identification, where linear mode reaches m/z above 100000 and reflectron mode improves accuracy for peptides. Orthogonal-acceleration ESI-TOF gives accurate mass for LC-MS at rates compatible with UHPLC. Multi-reflecting designs reach resolving power of 50000 to 100000 in a compact footprint for demanding screening. Consider mass accuracy, typically 1 to 5 ppm with calibration, resolution at your m/z range, acquisition rate, and dynamic range, which is narrower than quadrupoles. Decide whether tandem MS is needed, since TOF/TOF adds fragmentation for sequencing. Check software for microbial databases or polymer analysis, calibration strategy, and service support.
| MS mass range | m/z 500–30000 (reflectron) |
|---|---|
| MS/MS precursor range | m/z 700–4000 |
| MS resolution (m/z 2500) | ≥ 15000 FWHM |
| MS/MS resolution | ≥ 1500 FWHM (typical) |
| Precursor selection window | ~1–3 u |
| Mass accuracy, MS (internal) | ≤ 5 ppm |
| Mass accuracy, MS/MS fragments | ≤ 50 ppm |
| MS/MS sensitivity (Glu-fibrinopeptide) | ≤ 50 fmol on target |
| Laser repetition rate | up to 2 kHz |
| Collision gas | Helium or air, 1–2 keV collision energy |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
TOF/TOF uses high-energy CID at 1 to 2 keV, which yields additional fragment types such as immonium ions and w-ions that help differentiate isomeric residues. Ion trap CID is low-energy and mainly produces b and y ions, but supports multi-stage MSn.
MS/MS works best for precursors between about m/z 700 and 4000, where peptides fragment efficiently. Larger molecules such as intact proteins fragment poorly under CID, and alternative dissociation such as in-source decay is used for top-down sequencing.
Yes, but neutral loss of phosphoric acid (98 Da) from serine and threonine phosphopeptides can dominate spectra and limit site localization. Enrichment with titanium dioxide or immobilized metal affinity chromatography and careful interpretation are needed.
TOF analyzers theoretically have no upper mass limit, since every ion eventually reaches the detector. In practice MALDI-TOF in linear mode measures intact proteins and polymers above m/z 100000, while ESI-TOF instruments typically scan up to m/z 10000 to 20000, with multiply charged ions extending the effective molecular weight range.
A reflectron uses an electrostatic mirror to turn ions around. Ions with higher energy penetrate deeper and take longer in the mirror, so ions of the same mass but different energy arrive at the detector together. This corrects energy spread and lengthens the flight path, improving resolution.
With proper calibration, TOF instruments typically achieve 1 to 5 ppm mass accuracy, and multi-reflecting models can reach below 1 ppm with lock mass correction. Accuracy depends on temperature stability, calibration frequency, ion statistics and peak shape, so it must be verified during validation.

用于微生物鉴定的线性 MALDI-TOF 质谱仪