MALDI-TOF/TOF Tandem Mass Spectrometer

MALDI-TOF/TOF 串联质谱仪

  • SKU TOM-0003
  • TOF-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
MS mass rangem/z 500–30000 (reflectron)
MS/MS precursor rangem/z 700–4000
MS resolution (m/z 2500)≥ 15000 FWHM
MS/MS resolution≥ 1500 FWHM (typical)
Precursor selection window~1–3 u
Mass accuracy, MS (internal)≤ 5 ppm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D7134, ISO 11260, ISO/TS 16940

What is the MALDI-TOF/TOF Tandem Mass Spectrometer?

A MALDI-TOF/TOF uses two time-of-flight sections separated by a collision or fragmentation region, selecting a precursor ion and recording its product ions. It provides de novo peptide sequencing, post-translational modification mapping and structural confirmation of polymers and glycans.

What is the MALDI-TOF/TOF Tandem Mass Spectrometer?

A MALDI-TOF/TOF uses two time-of-flight sections separated by a collision or fragmentation region, selecting a precursor ion and recording its product ions. It provides de novo peptide sequencing, post-translational modification mapping and structural confirmation of polymers and glycans.

Overview

In a MALDI-TOF/TOF, ions generated by the laser travel through the first TOF section, where a timed ion gate selects a narrow precursor window of 1 to 3 u. The precursor then enters a collision cell with helium or air for high-energy collision-induced dissociation at 1 to 2 keV, or undergoes laser-induced dissociation. Product ions are reaccelerated and analyzed in a second TOF section with a reflectron. Because of high-energy CID, fragment spectra include immonium ions, side-chain fragments and w-type ions that help distinguish leucine from isoleucine. Resolution in MS mode is 15000 to 25000, and MS/MS resolution is typically 1000 to 4000. Laser repetition rates of 1 to 2 kHz accelerate data collection. It supports automated workflows in which MS spectra trigger selection of precursor peaks for MS/MS and database searching, for instance in protein identification after gel electrophoresis.

How does it work?

In a time-of-flight mass spectrometer, ions are given the same kinetic energy by an accelerating potential of several hundred volts to 20 kV and then drift through a field-free tube. Flight time scales with the square root of m/z, so the detector, a microchannel plate or fast electron multiplier, records ions in order of mass. Resolution depends on flight path length and on correcting initial energy spread. A reflectron, an ion mirror, extends the path and refocuses ions of equal mass but different energies, raising resolution from about 1000 to 20000 or more. MALDI sources pulse ions naturally, while orthogonal acceleration converts continuous ESI or ICP beams into pulses. Time-to-digital converters or fast digitizers at gigahertz rates record the signals.

What are the key features?

  • Timed ion gate precursor selection with 1 to 3 u isolation window
  • High-energy CID at 1 to 2 keV yielding immonium, side-chain and w-type fragments
  • Second TOF section with reflectron for MS/MS product ion analysis
  • Automated MS-to-MS/MS workflows with database search integration
  • 1 to 2 kHz laser enabling rapid spectrum accumulation for low-abundance peptides
  • Post-translational modification mapping for phosphorylation, glycosylation and acetylation

What are the technical specifications?

A typical maldi-tof/tof tandem mass spectrometer configuration offers MS mass range of m/z 500–30000 (reflectron), MS/MS precursor range of m/z 700–4000, MS resolution (m/z 2500) of ≥ 15000 FWHM, MS/MS resolution of ≥ 1500 FWHM (typical), precursor selection window of ~1–3 u and mass accuracy, MS (internal) of ≤ 5 ppm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The MALDI-TOF/TOF Tandem Mass Spectrometer is used in peptide sequencing and protein identification, phosphorylation and glycosylation site mapping, structural confirmation of synthetic polymers, oligosaccharide and glycan analysis and bacterial biomarker and toxin confirmation. Across the wider TOF-MS class, laboratories also deploy it for microbial identification in clinical microbiology, intact protein and peptide mass analysis and synthetic polymer molecular weight distribution.

Which standards and certifications apply?

Relevant standards and methods include ASTM D7134, ISO 11260, ISO/TS 16940, USP <1052> Biotechnology-Derived Articles, ASTM E2933, ISO 15189, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

TOF instruments are sensitive to temperature changes, because drift-tube expansion shifts flight time, so install them in a room stable within ±1 to 2 °C and away from drafts. Calibrate frequently with standards or internal lock mass to sustain mass accuracy below 5 ppm. MALDI systems require matrix preparation, such as alpha-cyano-4-hydroxycinnamic acid or sinapinic acid, and careful target plate cleaning. Detector microchannel plates degrade over time, so monitor gain and plan replacement, usually after several years. Keep the vacuum system leak tight, with analyzer pressure below 10^-6 mbar. Regulated laboratories, particularly those using MALDI for clinical microbiology, should confirm validated databases and software supporting audit trail and access control.

How do I select the right MALDI-TOF/TOF Tandem Mass Spectrometer?

Select MALDI-TOF/TOF when you need sequence or structural information from selected precursors, for example after 2D-gel spots or separated fractions. For high-throughput proteomics, LC-MS/MS is usually more productive. In an RFQ, specify MS and MS/MS resolution, precursor window, collision energy, laser rate and database search software.

How does it compare with other TOF-MS variants?

Select by ionization source and required resolving power. MALDI-TOF suits intact proteins, polymers and microbial identification, where linear mode reaches m/z above 100000 and reflectron mode improves accuracy for peptides. Orthogonal-acceleration ESI-TOF gives accurate mass for LC-MS at rates compatible with UHPLC. Multi-reflecting designs reach resolving power of 50000 to 100000 in a compact footprint for demanding screening. Consider mass accuracy, typically 1 to 5 ppm with calibration, resolution at your m/z range, acquisition rate, and dynamic range, which is narrower than quadrupoles. Decide whether tandem MS is needed, since TOF/TOF adds fragmentation for sequencing. Check software for microbial databases or polymer analysis, calibration strategy, and service support.

Full specifications

Full specifications
MS mass rangem/z 500–30000 (reflectron)
MS/MS precursor rangem/z 700–4000
MS resolution (m/z 2500)≥ 15000 FWHM
MS/MS resolution≥ 1500 FWHM (typical)
Precursor selection window~1–3 u
Mass accuracy, MS (internal)≤ 5 ppm
Mass accuracy, MS/MS fragments≤ 50 ppm
MS/MS sensitivity (Glu-fibrinopeptide)≤ 50 fmol on target
Laser repetition rateup to 2 kHz
Collision gasHelium or air, 1–2 keV collision energy

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Peptide sequencing and protein identification
  • Phosphorylation and glycosylation site mapping
  • Structural confirmation of synthetic polymers
  • Oligosaccharide and glycan analysis
  • Bacterial biomarker and toxin confirmation

Key features

  • Timed ion gate precursor selection with 1 to 3 u isolation window
  • High-energy CID at 1 to 2 keV yielding immonium, side-chain and w-type fragments
  • Second TOF section with reflectron for MS/MS product ion analysis
  • Automated MS-to-MS/MS workflows with database search integration
  • 1 to 2 kHz laser enabling rapid spectrum accumulation for low-abundance peptides
  • Post-translational modification mapping for phosphorylation, glycosylation and acetylation

Frequently asked questions about MALDI-TOF/TOF Tandem Mass Spectrometer

TOF/TOF uses high-energy CID at 1 to 2 keV, which yields additional fragment types such as immonium ions and w-ions that help differentiate isomeric residues. Ion trap CID is low-energy and mainly produces b and y ions, but supports multi-stage MSn.

Related models

All TOF-MS
ICP-TOF-MS System — product photo

ICP-TOF-MS System

电感耦合等离子体飞行时间质谱仪(ICP-TOF-MS)

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the MALDI-TOF/TOF Tandem Mass Spectrometer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote