Cell Block Slide Preparation System

细胞块制片系统

  • SKU SPS-0005
  • Slide Preparation Systems
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Samples per run1–12
Minimum cell numberabout 50–100 cells per block
Matrix optionsPlasma and thrombin, agar or gel
Cycle timeabout 2–4 h
Block formatStandard cassette
Section thickness3–5 µm on a microtome
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1

What is the Cell Block Slide Preparation System?

A cell block slide preparation system concentrates residual cells into a paraffin block and cuts sections for downstream ancillary testing and archiving. It is chosen when cytology samples must support immunohistochemistry or molecular assays.

What is the Cell Block Slide Preparation System?

A cell block slide preparation system concentrates residual cells into a paraffin block and cuts sections for downstream ancillary testing and archiving. It is chosen when cytology samples must support immunohistochemistry or molecular assays.

Overview

This system transforms residual cytology material into a tissue-like block so standard histology methods apply. Cells are recovered from the residual fluid by centrifugation, often bound with plasma and thrombin, agar or a commercial matrix, then processed through fixation, dehydration and paraffin infiltration. The block is sectioned on a microtome, giving multiple slides for hematoxylin and eosin, immunohistochemistry, special stains and molecular testing. For laboratories where cytology is the primary sample, this avoids a repeat biopsy and preserves material for later questions. Automated systems standardise pelleting, reagent exchange and processing, which improves cell recovery and reduces hands-on time. Very low cellularity samples remain a limitation, and interpretation should combine cytology and cell block findings.

How does it work?

A slide preparation system combines sample handling with deposition and, often, downstream slide processing. Depending on the design, it may dilute and mix the sample, deposit a measured volume onto a slide, spread or settle cells into a defined area, dry the slide, transfer it to a stainer and finally apply a coverslip. Many systems use barcode tracking so each sample, slide and reagent event is linked in a record. Motors, syringes or peristaltic pumps move fluid, and heated or ventilated zones control drying. Consistency comes from fixed volumes, timings and motions, which reduce operator-dependent variation. The quality of the output depends on correct sample collection, adequate cell numbers and complete reagent removal, because residual fluid or fixative causes uneven staining and poor adhesion.

What are the key features?

  • Recovery of residual cells by centrifugation
  • Matrix binding for a firm pellet
  • Automated fixation, dehydration and infiltration
  • Paraffin block suitable for microtomy
  • Sections for immunohistochemistry and molecular tests
  • Standardised processing reduces hands-on time

What are the technical specifications?

A typical cell block slide preparation system configuration offers samples per run of 1–12, minimum cell number of about 50–100 cells per block, matrix options of Plasma and thrombin, agar or gel, cycle time of about 2–4 h, block format of Standard cassette and section thickness of 3–5 µm on a microtome. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Cell Block Slide Preparation System is used in immunohistochemistry on cytology material, molecular testing from cytology samples, effusion and aspirate cell blocks and archival of residual cytology material. Across the wider Slide Preparation Systems class, laboratories also deploy it for cytology slide preparation, cervical screening programmes and body fluid cytology.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1, ISO 15189 and CLSI GP41. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the system on a stable bench with power and, if required, a drain, and keep the working area organised so tubes and slides cannot be mismatched. Follow the specified reagent volumes and timings, since too little fixative causes poor adhesion and too much leaves residue. Clean fluid lines and nozzles on schedule to prevent blockage and carryover, and check that barcodes are readable so records remain complete. Verify performance with control samples and record reagent lot numbers and run conditions. Train staff in safe handling of preservative fluids and in recognising preparation faults, and keep maintenance and quality records for accreditation.

How do I select the right Cell Block Slide Preparation System?

Specify a cell block system when cytology samples must support immunohistochemistry, molecular testing or archiving, or when a repeat biopsy should be avoided. Confirm minimum cell yield, matrix options, cycle time and block format. Assess suitability using your own low-cellularity sample types.

How does it compare with other Slide Preparation Systems variants?

Choose a preparation system by the level of automation you need and the output you must produce. A semi-automated system suits laboratories that want control over sample selection while automating deposition. A fully automated system gives standardised monolayers at throughput, often with integrated staining and coverslipping. Liquid-based systems define the reagent and consumable architecture, while cell block systems target ancillary testing. Compare samples per run, cycle time, spot size, barcode and record capability, consumable cost and compatibility with existing stainers. Check whether the system is open to third-party reagents, and confirm validation, training and service support before committing to a platform.

Full specifications

Full specifications
Samples per run1–12
Minimum cell numberabout 50–100 cells per block
Matrix optionsPlasma and thrombin, agar or gel
Cycle timeabout 2–4 h
Block formatStandard cassette
Section thickness3–5 µm on a microtome
Reagent exchangeAutomated
Power supply220 V, 50 Hz, about 0.3 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Immunohistochemistry on cytology material
  • Molecular testing from cytology samples
  • Effusion and aspirate cell blocks
  • Archival of residual cytology material

Key features

  • Recovery of residual cells by centrifugation
  • Matrix binding for a firm pellet
  • Automated fixation, dehydration and infiltration
  • Paraffin block suitable for microtomy
  • Sections for immunohistochemistry and molecular tests
  • Standardised processing reduces hands-on time

Frequently asked questions about Cell Block Slide Preparation System

No. Samples with very few cells may not yield a block with representative material, and the result may be non-diagnostic. It is best used alongside the cytology preparation, not as a replacement for it.

Request a quotation for the Cell Block Slide Preparation System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote