Liquid-Based Slide Preparation System
液基制片系统
- SKU SPS-0003
- Slide Preparation Systems
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Samples per run | 1–48 vials |
|---|---|
| Spot diameter | about 13–20 mm |
| Preservative volume | about 10–20 mL per vial |
| Cycle time | about 30–60 min per batch |
| Residual volume for molecular testing | about 1–4 mL |
| Reagent system | Open or proprietary |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1
What is the Liquid-Based Slide Preparation System?
A liquid-based slide preparation system disperses a preserved sample and deposits a thin monolayer for cervical and body-fluid cytology. It is chosen for standardised screening and for samples that also need molecular testing.
What is the Liquid-Based Slide Preparation System?
A liquid-based slide preparation system disperses a preserved sample and deposits a thin monolayer for cervical and body-fluid cytology. It is chosen for standardised screening and for samples that also need molecular testing.
Overview
This system is built around the liquid-based workflow: the sample is collected into preservative fluid, which fixes cells and lyses erythrocytes, and the vial is processed to deposit a thin, even monolayer within a defined circle. Debris removal uses a gradient, filter or membrane, and the deposited cells are dried and may be stained and coverslipped on the same platform. Because the whole sample is preserved, residual fluid remains available for reflex HPV or other molecular assays, which is a key advantage for screening programmes. Reagent volumes, spot size and consumable architecture are defined by the system, and some platforms are open to third-party reagents while others require proprietary consumables. Uniform cell distribution and reduced obscuring blood and mucus are the clinical benefits.
How does it work?
A slide preparation system combines sample handling with deposition and, often, downstream slide processing. Depending on the design, it may dilute and mix the sample, deposit a measured volume onto a slide, spread or settle cells into a defined area, dry the slide, transfer it to a stainer and finally apply a coverslip. Many systems use barcode tracking so each sample, slide and reagent event is linked in a record. Motors, syringes or peristaltic pumps move fluid, and heated or ventilated zones control drying. Consistency comes from fixed volumes, timings and motions, which reduce operator-dependent variation. The quality of the output depends on correct sample collection, adequate cell numbers and complete reagent removal, because residual fluid or fixative causes uneven staining and poor adhesion.
What are the key features?
- Preservative-based sample collection and fixation
- Thin monolayer deposition in a defined circle
- Debris removal by gradient, filter or membrane
- Residual fluid available for molecular testing
- Option for integrated staining and coverslipping
- Open or proprietary reagent architecture
What are the technical specifications?
A typical liquid-based slide preparation system configuration offers samples per run of 1–48 vials, spot diameter of about 13–20 mm, preservative volume of about 10–20 mL per vial, cycle time of about 30–60 min per batch, residual volume for molecular testing of about 1–4 mL and reagent system of Open or proprietary. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Liquid-Based Slide Preparation System is used in cervical cancer screening, reflex HPV testing, body fluid cytology and diagnostic gynaecological cytology. Across the wider Slide Preparation Systems class, laboratories also deploy it for cytology slide preparation, cervical screening programmes and body fluid cytology.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1, ISO 15189 and CLSI GP41. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the system on a stable bench with power and, if required, a drain, and keep the working area organised so tubes and slides cannot be mismatched. Follow the specified reagent volumes and timings, since too little fixative causes poor adhesion and too much leaves residue. Clean fluid lines and nozzles on schedule to prevent blockage and carryover, and check that barcodes are readable so records remain complete. Verify performance with control samples and record reagent lot numbers and run conditions. Train staff in safe handling of preservative fluids and in recognising preparation faults, and keep maintenance and quality records for accreditation.
How do I select the right Liquid-Based Slide Preparation System?
Specify a liquid-based system for organised screening and for programmes that combine cytology with HPV or molecular testing. Confirm throughput, spot size, residual volume available for molecular work, reagent architecture and consumable cost. Check compatibility with your existing staining and archiving workflow.
How does it compare with other Slide Preparation Systems variants?
Choose a preparation system by the level of automation you need and the output you must produce. A semi-automated system suits laboratories that want control over sample selection while automating deposition. A fully automated system gives standardised monolayers at throughput, often with integrated staining and coverslipping. Liquid-based systems define the reagent and consumable architecture, while cell block systems target ancillary testing. Compare samples per run, cycle time, spot size, barcode and record capability, consumable cost and compatibility with existing stainers. Check whether the system is open to third-party reagents, and confirm validation, training and service support before committing to a platform.
Full specifications
| Samples per run | 1–48 vials |
|---|---|
| Spot diameter | about 13–20 mm |
| Preservative volume | about 10–20 mL per vial |
| Cycle time | about 30–60 min per batch |
| Residual volume for molecular testing | about 1–4 mL |
| Reagent system | Open or proprietary |
| Slide format | 25 × 75 mm standard |
| Power supply | 220 V, 50 Hz, about 0.5–1 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cervical cancer screening
- Reflex HPV testing
- Body fluid cytology
- Diagnostic gynaecological cytology
Key features
- Preservative-based sample collection and fixation
- Thin monolayer deposition in a defined circle
- Debris removal by gradient, filter or membrane
- Residual fluid available for molecular testing
- Option for integrated staining and coverslipping
- Open or proprietary reagent architecture
Frequently asked questions about Liquid-Based Slide Preparation System
Typically 1 to 4 mL of preserved fluid remains after preparation, depending on the platform and the volume used for the slide. Confirm the validated molecular workflow and the minimum volume each assay requires before relying on reflex testing.
Thickness depends on the number of cells in the sample and the deposition volume. Very cellular samples can still give overlapping cells, so dilution steps and density control are used to keep the preparation readable.
Yes, many liquid-based systems prepare urine, effusions and aspirates as well, often with a modified protocol. Confirm that the manufacturer has validated the sample type and that cell recovery is adequate for your diagnostic needs.
It automates fluid handling and cell deposition, and often drying, staining and coverslipping. Sample dilution, mixing, measured deposition and barcode tracking are typical functions, so the output is a standardised, traceable slide ready for microscopy.
Only if daily volume is high or standardisation is critical. Semi-automated systems that automate deposition while leaving sample selection to the operator often suit moderate volumes and cost considerably less, with simpler maintenance.
Through barcoded sample vials and slides linked in the instrument software, so every preparation step is recorded against the correct specimen. Manual systems rely on labels and written logs, which are more error-prone at high volume.