Liquid-Based Cytology Processor

液基细胞学处理机

  • SKU CYP-0001
  • Cytology Processors
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Samples per run1–48 vials
Spot diameterabout 13–20 mm
Preservative volumeabout 10–20 mL per vial
Cycle timeabout 30–60 min per batch
Reagent systemOpen or proprietary
Slide format25 × 75 mm standard
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1

What is the Liquid-Based Cytology Processor?

A liquid-based cytology processor disperses a sample in preservative fluid and prepares a thin monolayer on a slide for cervical and other cytology screening. It is the standard platform in high-volume screening programmes.

What is the Liquid-Based Cytology Processor?

A liquid-based cytology processor disperses a sample in preservative fluid and prepares a thin monolayer on a slide for cervical and other cytology screening. It is the standard platform in high-volume screening programmes.

Overview

The liquid-based cytology processor is the backbone of modern cervical screening. The sample is collected into a methanol or alcohol-based preservative, which fixes cells and lyses red blood cells, and the vial is loaded into the instrument. The processor mixes or disperses the sample, uses a density gradient, filter or membrane to remove debris, and deposits a representative cell population as a thin, evenly distributed monolayer within a defined circle. Most systems process a batch of vials per run, with programmable protocols, and many can be coupled to an automated stainer and coverslipper to complete the slide. Advantages include better cell distribution, fewer obscuring elements and the option for reflex molecular testing from the residual fluid. Reagent cost, consumable architecture and whether the system is open or closed are major procurement considerations.

How does it work?

A cytology processor starts with a sample collected into a preservative solution, which fixes cells and lyses red blood cells. The instrument then separates diagnostically useful cells from mucus, blood and inflammatory debris using one of several approaches. Density gradient or centrifugation methods layer the sample over a reagent so cells of interest band at a known density. Filtration and membrane methods trap cells on a surface with a defined pore size, then transfer them to a slide. Some platforms use an adhesive or charged coating to capture cells while washing away the rest. The result is a thin, evenly distributed preparation with cells concentrated in a defined area, which improves screening speed and reduces obscuring material. Cell recovery, spot area and carryover control determine performance.

What are the key features?

  • Preservative-based sample dispersion and cell fixation
  • Thin monolayer deposition in a defined circle
  • Batch processing of multiple sample vials
  • Programmable protocols for different sample types
  • Option for reflex molecular testing from residual fluid
  • Coupling to automated stainer and coverslipper

What are the technical specifications?

A typical liquid-based cytology processor configuration offers samples per run of 1–48 vials, spot diameter of about 13–20 mm, preservative volume of about 10–20 mL per vial, cycle time of about 30–60 min per batch, reagent system of Open or proprietary and slide format of 25 × 75 mm standard. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Liquid-Based Cytology Processor is used in cervical cancer screening, high-volume cytology programmes, reflex HPV or molecular testing and diagnostic gynaecological cytology. Across the wider Cytology Processors class, laboratories also deploy it for cervical cancer screening, urine cytology and body fluid cytology.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1, ISO 15189 and CLSI GP41. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the processor on a stable bench near a drain and power outlet, and keep the working area free of clutter so sample tubes can be tracked. Follow the specified reagent volumes and incubation or centrifugation conditions, because under-processing leaves debris while over-processing loses cells. Change reagents and clean fluid paths on schedule to prevent contamination and biofilm. Verify performance with control samples and record reagent lot numbers, run dates and results. Train staff in safe handling of preservative fluids, which may contain methanol or other hazardous substances, and dispose of waste according to local regulations.

How do I select the right Liquid-Based Cytology Processor?

Choose a liquid-based processor for organised cervical screening and other high-volume work where standardised monolayers matter. Confirm throughput, cycle time, spot size, reagent architecture and compatibility with existing slide handling. Evaluate consumable cost per sample carefully, since it dominates long-term expense.

How does it compare with other Cytology Processors variants?

Choose a processor by sample type, throughput and whether the laboratory prefers an open or closed reagent system. For high-volume cervical screening, a liquid-based processor with automated staining and coverslipping gives the most consistent results. For body fluids and fine-needle aspirates, a centrifugation or filter-based method often yields better cell recovery from scant samples. Cell block processors support immunohistochemistry and molecular testing on residual cells. Compare samples per run, reagent consumption, carryover prevention, consumable cost and whether the platform accepts third-party reagents. Confirm validation, training and service support, and check that the output format fits existing stainers and coverslippers.

Full specifications

Full specifications
Samples per run1–48 vials
Spot diameterabout 13–20 mm
Preservative volumeabout 10–20 mL per vial
Cycle timeabout 30–60 min per batch
Reagent systemOpen or proprietary
Slide format25 × 75 mm standard
Carryover controlDedicated tips or washing cycles
Power supply220 V, 50 Hz, about 0.5–1 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Cervical cancer screening
  • High-volume cytology programmes
  • Reflex HPV or molecular testing
  • Diagnostic gynaecological cytology

Key features

  • Preservative-based sample dispersion and cell fixation
  • Thin monolayer deposition in a defined circle
  • Batch processing of multiple sample vials
  • Programmable protocols for different sample types
  • Option for reflex molecular testing from residual fluid
  • Coupling to automated stainer and coverslipper

Frequently asked questions about Liquid-Based Cytology Processor

It produces a thinner, more evenly distributed cell layer with less blood and mucus, so abnormal cells are easier to find and smears are easier to screen. It also allows molecular testing from the same preserved sample when needed.