Double-Chamber Cytocentrifuge
双腔离心甩片机
- SKU CYT-0002
- Cytocentrifuges
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- IEC 61010-2-020 compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Number of chambers | 2 |
|---|---|
| Spin speed | 200–2000 rpm |
| Timer range | 1–99 min |
| Spot diameter | about 6–13 mm |
| Sample volume | 0.1–1 mL per chamber |
| Slide format | 25 × 75 mm standard |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Double-Chamber Cytocentrifuge?
A double-chamber cytocentrifuge prepares two samples in one run, roughly doubling throughput while keeping the same bench footprint. It suits moderate-volume haematology and cytology laboratories that process body fluids throughout the day.
What is the Double-Chamber Cytocentrifuge?
A double-chamber cytocentrifuge prepares two samples in one run, roughly doubling throughput while keeping the same bench footprint. It suits moderate-volume haematology and cytology laboratories that process body fluids throughout the day.
Overview
The double-chamber cytocentrifuge holds two sample chambers, usually opposite each other in the rotor so the load is naturally balanced and two slides are produced per run. Throughput is roughly twice that of a single-chamber model with little extra bench space, which makes it a practical choice for laboratories that process a steady daily stream of CSF, urine and serous fluids. Speed and timer controls are similar, and some models allow the two chambers to be used independently so a single sample can still be processed when needed. Balanced loading is determined by the rotor design, which simplifies correct use. Cleaning takes a little longer than with one chamber, and each chamber needs its own card or filter. Check that the two positions give equivalent cell recovery and spot size.
How does it work?
A cytocentrifuge is a low-speed centrifuge fitted with sample chambers that hold a microscope slide against a card or gasket. The fluid sample is placed in the chamber and centrifuged, so cells move out of suspension and settle onto the slide within a defined circle of typically 6 to 13 mm. Absorbent card or filter paper beside the slide wicks away the supernatant, leaving cells concentrated in a monolayer with minimal protein background. Spin speed and time, usually 500 to 1500 rpm for 3 to 10 minutes, control cell density and flattening. Faster spins pack more cells but flatten them and increase background; slower spins preserve nuclear detail. Some instruments add a cytology funnel, a slide clip and a disassembly system that protects the operator from aerosols.
What are the key features?
- Two sample chambers in one rotor
- Two slides prepared per run
- Natural load balancing from rotor design
- Independent chamber operation on selected models
- Same bench footprint as single-chamber units
- Adjustable speed and timer
What are the technical specifications?
A typical double-chamber cytocentrifuge configuration offers number of chambers of 2, spin speed of 200–2000 rpm, timer range of 1–99 min, spot diameter of about 6–13 mm, sample volume of 0.1–1 mL per chamber and slide format of 25 × 75 mm standard. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Double-Chamber Cytocentrifuge is used in moderate-volume body fluid cytology, haematology laboratories, urine cytology and serous effusion preparation. Across the wider Cytocentrifuges class, laboratories also deploy it for cerebrospinal fluid cytology, body fluid cell counts and urine cytology.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1 and ISO 15189. Certification candidates for this model are CE, IEC 61010-1 compliance and IEC 61010-2-020 compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the cytocentrifuge on a level bench and balance the rotor or chamber loads exactly as specified, because imbalance causes vibration and poor cell distribution. Use the recommended absorbent cards or filters and replace them for every sample to prevent carryover. Disassemble and clean chambers after use, and disinfect according to the laboratory biosafety policy, since samples may be infectious. Verify the timer and speed at defined intervals with a tachometer or service check. Record spin conditions for each sample, keep maintenance records and train staff in safe handling of aerosols and sharps from broken slides.
How do I select the right Double-Chamber Cytocentrifuge?
Select a double-chamber model for steady daily work where two preparations per run double output without more bench space. Confirm that both positions give equivalent cell recovery and can be loaded independently if needed. Compare consumable cost per slide, since two chambers use two cards per run.
How does it compare with other Cytocentrifuges variants?
Choose a cytocentrifuge by sample type, daily volume and the number of chambers needed. Single-chamber models are economical and suit low volumes or occasional body-fluid work. Double and multi-chamber instruments process several samples in one run and reduce turnaround, which matters in busy haematology laboratories. A programmable unit lets you store spin protocols for different fluids, so fragile cells are not over-packed. Micro-volume models are designed for small samples such as paediatric CSF. Compare chamber design, spot size, spin speed range, timer resolution, aerosol containment, ease of disassembly and cleaning, and whether cytology funnels and slides are standard items. Check how the instrument handles blood-contaminated fluids, since red cell carryover affects interpretation.
Full specifications
| Number of chambers | 2 |
|---|---|
| Spin speed | 200–2000 rpm |
| Timer range | 1–99 min |
| Spot diameter | about 6–13 mm |
| Sample volume | 0.1–1 mL per chamber |
| Slide format | 25 × 75 mm standard |
| Aerosol control | Sealed lids with clips |
| Power supply | 220 V, 50 Hz, about 0.3 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Moderate-volume body fluid cytology
- Haematology laboratories
- Urine cytology
- Serous effusion preparation
Key features
- Two sample chambers in one rotor
- Two slides prepared per run
- Natural load balancing from rotor design
- Independent chamber operation on selected models
- Same bench footprint as single-chamber units
- Adjustable speed and timer
Frequently asked questions about Double-Chamber Cytocentrifuge
On most models the rotor is designed so that either one or two chambers can be used safely, and a single sample can still be processed. Confirm the manufacturer's guidance, because some rotors require balanced pairs.
It should be, but small differences can appear if seals wear or a chamber is loaded unevenly. Verify periodically by preparing the same sample in both positions and comparing spot size and cell density.
Slightly, because there are two chambers, cards and lids to dismantle and disinfect. Cleaning time per slide is usually lower than for a single-chamber instrument, since both chambers are handled in one session.
It concentrates cells from body fluids onto a small, defined area of a glass slide. Typical uses are cerebrospinal fluid, urine, pleural and peritoneal fluids, and other samples with few cells that need a concentrated preparation for microscopy.
A regular centrifuge pellets cells in a tube, while a cytocentrifuge deposits them directly onto a slide in a defined circle. The sample chamber, absorbent card and low-speed protocol are designed to give a monolayer rather than a tube pellet.
Speed determines cell density and morphology. Lower speeds preserve fine nuclear detail but risk losing cells, while higher speeds recover more cells but flatten them and increase background. Most body fluids are spun at about 500 to 1500 rpm for 3 to 10 minutes.