Ultra-Low Temperature Refrigerated Centrifuge
超低温冷冻离心机
- SKU REC-0005
- Refrigerated Centrifuges
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | -40 to 40 °C (at moderate speed) |
|---|---|
| Temperature at maximum speed | approx. -10 °C |
| Maximum speed | 12,000–20,000 rpm |
| Maximum RCF | approx. 25,000 x g |
| Maximum capacity | 6 x 50 mL or 24 x 1.5/2.0 mL |
| Pre-cool time to -20 °C | 30–60 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Ultra-Low Temperature Refrigerated Centrifuge?
An ultra-low temperature refrigerated centrifuge uses a high-capacity or cascade compressor to hold the chamber at -20 to -40 C during high-speed spins. It is chosen for labile biologics, lipid work and protocols requiring sub-zero temperatures that standard 4 C units cannot sustain.
What is the Ultra-Low Temperature Refrigerated Centrifuge?
An ultra-low temperature refrigerated centrifuge uses a high-capacity or cascade compressor to hold the chamber at -20 to -40 C during high-speed spins. It is chosen for labile biologics, lipid work and protocols requiring sub-zero temperatures that standard 4 C units cannot sustain.
Overview
Standard refrigerated centrifuges typically bottom out at -10 to -20 C, and heat load at top speed can limit achievable temperature to 4 C or above. The ultra-low temperature variant uses an oversized compressor or two-stage cascade refrigeration with well-insulated chambers to reach -20 to -40 C at moderate speeds and about -10 C at maximum speed. Typical rotors include 6 x 50 mL and 12 x 15 mL fixed-angle sets at 12,000 to 20,000 rpm, reaching about 25,000 x g, and microtube rotors. Precision sensors monitor both chamber and rotor. Stainless chambers with heated door gaskets reduce ice formation, and automatic defrost is essential. Longer pre-cool times of 30 to 60 minutes should be expected. Energy consumption is higher and noise is typically 60 to 65 dB(A).
How does it work?
Rotor spinning in air generates frictional heat that rises with the square or cube of speed, often adding 10 to 20 C within minutes at high RCF. A refrigerated centrifuge counters this with a hermetic compressor, condenser, evaporator coil wrapped around the chamber and a sensor that measures chamber or rotor temperature. A PID controller modulates compressor duty and sometimes a heater to hold the setpoint within plus or minus 1 to 2 C. Environmentally preferred refrigerants such as R290 or R134a are common. Insulated chambers, door gaskets and a defrost or drain function manage condensation. The drive system, rotor recognition, imbalance detection and lid lock operate as in ambient centrifuges, but controllers also limit speed or alert if the target temperature cannot be maintained.
What are the key features?
- Cascade or high-capacity compressor reaches -20 to -40 C at moderate speeds
- Dual chamber and rotor temperature sensors improve control accuracy
- Heated door gasket and automatic defrost limit ice build-up
- Fixed-angle rotors up to 20,000 rpm for 15 mL and 50 mL tubes
- Alarm logging records deviations from setpoint during long runs
What are the technical specifications?
A typical ultra-low temperature refrigerated centrifuge configuration offers temperature range of -40 to 40 °C (at moderate speed), temperature at maximum speed of approx. -10 °C, maximum speed of 12,000–20,000 rpm, maximum RCF of approx. 25,000 x g, maximum capacity of 6 x 50 mL or 24 x 1.5/2.0 mL and pre-cool time to -20 °C of 30–60 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Ultra-Low Temperature Refrigerated Centrifuge is used in lipid and membrane preparations, labile biologics processing, protocols requiring sub-zero spins and cryoprecipitate and plasma fractionation research. Across the wider Refrigerated Centrifuges class, laboratories also deploy it for protein and enzyme purification, cell and tissue pelleting at 4 C and blood component preparation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, ISO 9001, ISO 13485, AABB Standards for Blood Banks and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the centrifuge with at least 10 to 30 cm of clearance for condenser airflow and avoid rooms above 32 C, since cooling capacity falls with ambient temperature. Allow the unit to stand upright for several hours after transport before powering the compressor. Clean condenser fins every 3 to 6 months and leave the lid open after runs to dry the chamber. Verify chamber temperature annually with a calibrated probe, together with speed and timer. Refrigerants and compressors are subject to local environmental rules, so confirm refrigerant type at purchase. For blood banking or GMP environments, plan IQ/OQ, calibration records and temperature monitoring.
How do I select the right Ultra-Low Temperature Refrigerated Centrifuge?
Choose this variant only when protocols specify temperatures below -10 C during the spin, because it costs more, draws more power and cools more slowly than standard refrigerated siblings. In the RFQ, specify required temperature at the target speed, rotor type, pre-cool time expectations, noise limits and power supply.
How does it compare with other Refrigerated Centrifuges variants?
Specify the temperature window first: standard work at 4 C needs -10 C capability, while frozen sample handling or long high-speed runs benefit from -20 C. Next determine speed and capacity, from microtube units reaching 21,000 x g to floor units with 6 x 500 mL bottles. Check temperature accuracy and pre-cool time, because delays affect throughput. Consider rotor compatibility and whether the same instrument must run plates, blood bags or bottles. For regulated environments, look for temperature logging, audit trails and alarms. Refrigerant type, ambient conditions up to 32 C, noise and energy use also matter, along with the cooling method: compressor-based systems are typical, while thermoelectric cooling is used only for small, low-power units.
Full specifications
| Temperature range | -40 to 40 °C (at moderate speed) |
|---|---|
| Temperature at maximum speed | approx. -10 °C |
| Maximum speed | 12,000–20,000 rpm |
| Maximum RCF | approx. 25,000 x g |
| Maximum capacity | 6 x 50 mL or 24 x 1.5/2.0 mL |
| Pre-cool time to -20 °C | 30–60 min |
| Refrigeration system | Two-stage cascade or high-capacity compressor |
| Temperature accuracy | ±2 °C |
| Noise level | ≤ 65 dB(A) |
| Power supply | 220 V, 50/60 Hz, 2–3 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Lipid and membrane preparations
- Labile biologics processing
- Protocols requiring sub-zero spins
- Cryoprecipitate and plasma fractionation research
Key features
- Cascade or high-capacity compressor reaches -20 to -40 C at moderate speeds
- Dual chamber and rotor temperature sensors improve control accuracy
- Heated door gasket and automatic defrost limit ice build-up
- Fixed-angle rotors up to 20,000 rpm for 15 mL and 50 mL tubes
- Alarm logging records deviations from setpoint during long runs
Frequently asked questions about Ultra-Low Temperature Refrigerated Centrifuge
Not all. Standard models commonly reach -10 C at low to moderate speed, and heat from windage at top speed raises the minimum. Ultra-low models use stronger or cascade compressors to maintain -20 C or below, but always check published temperature against speed curves.
Humid room air entering the chamber condenses and freezes on cold surfaces, especially when the lid opens. Ice reduces cooling efficiency and can unbalance rotors. Defrost cycles, heated gaskets and drying the chamber after use help.
Yes. Many plastics become brittle at low temperatures. Use polypropylene, polycarbonate or polyallomer tubes that the manufacturer rates for the temperature and RCF, and avoid thin-walled or repeatedly frozen tubes that may crack.
Rotor friction with air heats the chamber, raising sample temperature by 10 to 20 C during long or high-speed runs. Refrigeration keeps proteins, enzymes, cells and nucleic acids from denaturing or losing activity. It also ensures repeatability by holding a consistent, documented temperature.
Most refrigerated centrifuges operate from -10 C to 40 C, and some models reach -20 C or 4 C minimum at maximum speed. Check the published temperature at full speed and ambient 25 C, since heat load at top speed can limit the minimum achievable setpoint.
Pre-cooling to 4 C usually takes 10 to 30 minutes depending on chamber volume and rotor mass. Floor-standing units with large rotors take longer. Pre-chilled rotors and a fast-cool function shorten the time and ensure the first sample starts at temperature.