Benchtop Refrigerated Centrifuge
台式冷冻离心机
- SKU REC-0001
- Refrigerated Centrifuges
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum speed | 4,000–15,000 rpm |
|---|---|
| Maximum RCF | up to approx. 21,000 x g |
| Maximum capacity | 4 x 100 mL or 6 x 50 mL |
| Temperature range | -10 to 40 °C |
| Temperature accuracy | ±2 °C |
| Pre-cool time to 4 °C | 10–20 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Benchtop Refrigerated Centrifuge?
A benchtop refrigerated centrifuge is a bench-mounted unit with a compressor holding -10 to 40 C at up to 6,000 to 15,000 rpm. It is the general-purpose choice for research and clinical laboratories needing cold conditions for 15 mL and 50 mL tubes, plates and small bottles.
What is the Benchtop Refrigerated Centrifuge?
A benchtop refrigerated centrifuge is a bench-mounted unit with a compressor holding -10 to 40 C at up to 6,000 to 15,000 rpm. It is the general-purpose choice for research and clinical laboratories needing cold conditions for 15 mL and 50 mL tubes, plates and small bottles.
Overview
The benchtop refrigerated centrifuge is the most commonly used configuration for cold separation. A compact steel chamber is paired with a 0.5 to 1.5 kW hermetic compressor, and interchangeable rotors cover 4 x 100 mL swing-bucket, 6 x 50 mL fixed-angle, 24 x 1.5/2.0 mL microtube and plate formats. Maximum speeds range from 4,000 rpm for large-capacity versions to 15,000 rpm for multi-purpose models, with RCF up to about 21,000 x g. Chamber temperature is held within plus or minus 2 C, and pre-cool to 4 C takes 10 to 20 minutes. The controller stores 20 to 99 programs and offers 9 to 10 acceleration and braking profiles. Units weigh 50 to 100 kg and require single-phase 220 V power. They are appropriate for laboratories that need versatility without the footprint of floor models.
How does it work?
Rotor spinning in air generates frictional heat that rises with the square or cube of speed, often adding 10 to 20 C within minutes at high RCF. A refrigerated centrifuge counters this with a hermetic compressor, condenser, evaporator coil wrapped around the chamber and a sensor that measures chamber or rotor temperature. A PID controller modulates compressor duty and sometimes a heater to hold the setpoint within plus or minus 1 to 2 C. Environmentally preferred refrigerants such as R290 or R134a are common. Insulated chambers, door gaskets and a defrost or drain function manage condensation. The drive system, rotor recognition, imbalance detection and lid lock operate as in ambient centrifuges, but controllers also limit speed or alert if the target temperature cannot be maintained.
What are the key features?
- Interchangeable rotors support tubes, bottles, microtubes and plates
- Hermetic compressor holds -10 to 40 C within plus or minus 2 C
- Pre-cool function reaches 4 C in about 10 to 20 minutes
- Stores 20 to 99 programs with selectable ramp profiles
- Automatic defrost and condensate drain keep the chamber dry
What are the technical specifications?
A typical benchtop refrigerated centrifuge configuration offers maximum speed of 4,000–15,000 rpm, maximum RCF of up to approx. 21,000 x g, maximum capacity of 4 x 100 mL or 6 x 50 mL, temperature range of -10 to 40 °C, temperature accuracy of ±2 °C and pre-cool time to 4 °C of 10–20 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Refrigerated Centrifuge is used in protein and enzyme preparation, cell pelleting at 4 C, nucleic acid extraction and plate centrifugation in cold. Across the wider Refrigerated Centrifuges class, laboratories also deploy it for protein and enzyme purification, cell and tissue pelleting at 4 C and blood component preparation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, ISO 9001, ISO 13485, AABB Standards for Blood Banks and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the centrifuge with at least 10 to 30 cm of clearance for condenser airflow and avoid rooms above 32 C, since cooling capacity falls with ambient temperature. Allow the unit to stand upright for several hours after transport before powering the compressor. Clean condenser fins every 3 to 6 months and leave the lid open after runs to dry the chamber. Verify chamber temperature annually with a calibrated probe, together with speed and timer. Refrigerants and compressors are subject to local environmental rules, so confirm refrigerant type at purchase. For blood banking or GMP environments, plan IQ/OQ, calibration records and temperature monitoring.
How do I select the right Benchtop Refrigerated Centrifuge?
Select the benchtop refrigerated model for versatile cold work with volumes up to 600 mL per run. It has less capacity than floor-standing siblings and lower maximum speed than high-speed models. In the RFQ, list rotors, RCF, temperature range, program count, refrigerant preference and ambient room conditions.
How does it compare with other Refrigerated Centrifuges variants?
Specify the temperature window first: standard work at 4 C needs -10 C capability, while frozen sample handling or long high-speed runs benefit from -20 C. Next determine speed and capacity, from microtube units reaching 21,000 x g to floor units with 6 x 500 mL bottles. Check temperature accuracy and pre-cool time, because delays affect throughput. Consider rotor compatibility and whether the same instrument must run plates, blood bags or bottles. For regulated environments, look for temperature logging, audit trails and alarms. Refrigerant type, ambient conditions up to 32 C, noise and energy use also matter, along with the cooling method: compressor-based systems are typical, while thermoelectric cooling is used only for small, low-power units.
Full specifications
| Maximum speed | 4,000–15,000 rpm |
|---|---|
| Maximum RCF | up to approx. 21,000 x g |
| Maximum capacity | 4 x 100 mL or 6 x 50 mL |
| Temperature range | -10 to 40 °C |
| Temperature accuracy | ±2 °C |
| Pre-cool time to 4 °C | 10–20 min |
| Program memory | 20–99 methods |
| Refrigerant | R290 or R134a |
| Noise level | ≤ 62 dB(A) |
| Power supply | 220 V, 50/60 Hz, 0.8–1.5 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Protein and enzyme preparation
- Cell pelleting at 4 C
- Nucleic acid extraction
- Plate centrifugation in cold
Key features
- Interchangeable rotors support tubes, bottles, microtubes and plates
- Hermetic compressor holds -10 to 40 C within plus or minus 2 C
- Pre-cool function reaches 4 C in about 10 to 20 minutes
- Stores 20 to 99 programs with selectable ramp profiles
- Automatic defrost and condensate drain keep the chamber dry
Frequently asked questions about Benchtop Refrigerated Centrifuge
Most models can hold 4 C at maximum speed when ambient temperature is 25 C or less, but performance depends on rotor, load and room conditions. Check the manufacturer's data for temperature at maximum speed and request validation at your operating conditions.
Allow 10 to 20 cm at the rear and sides for condenser airflow, and avoid placing against walls or in enclosed cabinets. Restricted ventilation raises condenser temperature, lengthens cooling time and shortens compressor life.
Yes. The temperature can be set to 20 to 25 C or the compressor turned off, and the unit then functions as an ambient centrifuge. Some units also hold 37 C using a heater for warm-spin applications.
Rotor friction with air heats the chamber, raising sample temperature by 10 to 20 C during long or high-speed runs. Refrigeration keeps proteins, enzymes, cells and nucleic acids from denaturing or losing activity. It also ensures repeatability by holding a consistent, documented temperature.
Most refrigerated centrifuges operate from -10 C to 40 C, and some models reach -20 C or 4 C minimum at maximum speed. Check the published temperature at full speed and ambient 25 C, since heat load at top speed can limit the minimum achievable setpoint.
Pre-cooling to 4 C usually takes 10 to 30 minutes depending on chamber volume and rotor mass. Floor-standing units with large rotors take longer. Pre-chilled rotors and a fast-cool function shorten the time and ensure the first sample starts at temperature.