Blood Bank Refrigerated Centrifuge
血库冷冻离心机
- SKU REC-0004
- Refrigerated Centrifuges
- CE IVD or MDD (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum speed | 3,000–5,000 rpm |
|---|---|
| Maximum RCF | approx. 3,500–5,500 x g |
| Bag capacity | 4–6 x 250–500 mL bags |
| Temperature range | -10 to 40 °C |
| Temperature accuracy | ±1 °C |
| Acceleration/braking profiles | 10 selectable, including soft start and no brake |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Blood Bank Refrigerated Centrifuge?
A blood bank refrigerated centrifuge processes blood bags of 250 to 500 mL at 20 to 22 C or 4 C with programmable soft-start profiles. It is used by blood centers for separating whole blood into red cells, plasma and platelet-rich fractions under documented temperature control.
What is the Blood Bank Refrigerated Centrifuge?
A blood bank refrigerated centrifuge processes blood bags of 250 to 500 mL at 20 to 22 C or 4 C with programmable soft-start profiles. It is used by blood centers for separating whole blood into red cells, plasma and platelet-rich fractions under documented temperature control.
Overview
Blood component preparation places specific demands on centrifuges, and this variant is built around them. Large swing-out buckets hold 4 to 6 blood bags of 250 to 500 mL, often with tubing outlets or pockets that keep bags flat. Typical speeds are 3,000 to 5,000 rpm, giving 3,500 to 5,500 x g, used in heavy or light spin protocols. Temperature control supports platelet-preserving 20 to 24 C operation as well as 4 C for red cell and plasma separation, with accuracy of plus or minus 1 C. Programmable acceleration and braking profiles, including soft start and no-brake stop, protect component integrity. Data logging and alarm output support traceability in line with blood establishment quality systems. Stainless buckets resist disinfectants. Chambers and cups are sized for safety with leaking bags.
How does it work?
Rotor spinning in air generates frictional heat that rises with the square or cube of speed, often adding 10 to 20 C within minutes at high RCF. A refrigerated centrifuge counters this with a hermetic compressor, condenser, evaporator coil wrapped around the chamber and a sensor that measures chamber or rotor temperature. A PID controller modulates compressor duty and sometimes a heater to hold the setpoint within plus or minus 1 to 2 C. Environmentally preferred refrigerants such as R290 or R134a are common. Insulated chambers, door gaskets and a defrost or drain function manage condensation. The drive system, rotor recognition, imbalance detection and lid lock operate as in ambient centrifuges, but controllers also limit speed or alert if the target temperature cannot be maintained.
What are the key features?
- Swing-out buckets hold 4 to 6 blood bags of 250 to 500 mL
- Temperature control from 4 C to 24 C supports platelet and red cell protocols
- Soft-start and no-brake stop profiles preserve component quality
- Data logging and alarm output support blood establishment traceability
- Stainless steel buckets resist disinfectants and bag leakage
What are the technical specifications?
A typical blood bank refrigerated centrifuge configuration offers maximum speed of 3,000–5,000 rpm, maximum RCF of approx. 3,500–5,500 x g, bag capacity of 4–6 x 250–500 mL bags, temperature range of -10 to 40 °C, temperature accuracy of ±1 °C and acceleration/braking profiles of 10 selectable, including soft start and no brake. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Blood Bank Refrigerated Centrifuge is used in whole blood component separation, platelet-rich plasma preparation, plasma and red cell concentrate production and blood center quality control. Across the wider Refrigerated Centrifuges class, laboratories also deploy it for protein and enzyme purification, cell and tissue pelleting at 4 C and blood component preparation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, ISO 9001, ISO 13485, AABB Standards for Blood Banks and GB 4793.1. Certification candidates for this model are CE IVD or MDD, ISO 13485 manufacturing and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the centrifuge with at least 10 to 30 cm of clearance for condenser airflow and avoid rooms above 32 C, since cooling capacity falls with ambient temperature. Allow the unit to stand upright for several hours after transport before powering the compressor. Clean condenser fins every 3 to 6 months and leave the lid open after runs to dry the chamber. Verify chamber temperature annually with a calibrated probe, together with speed and timer. Refrigerants and compressors are subject to local environmental rules, so confirm refrigerant type at purchase. For blood banking or GMP environments, plan IQ/OQ, calibration records and temperature monitoring.
How do I select the right Blood Bank Refrigerated Centrifuge?
Choose this variant for routine component preparation in blood centers and hospital transfusion services, where bag format, temperature and traceability are regulated. It is more specialized than general refrigerated siblings. In the RFQ, specify bag sizes, bucket count, temperature setpoints, data interface, alarms and regulatory pathway.
How does it compare with other Refrigerated Centrifuges variants?
Specify the temperature window first: standard work at 4 C needs -10 C capability, while frozen sample handling or long high-speed runs benefit from -20 C. Next determine speed and capacity, from microtube units reaching 21,000 x g to floor units with 6 x 500 mL bottles. Check temperature accuracy and pre-cool time, because delays affect throughput. Consider rotor compatibility and whether the same instrument must run plates, blood bags or bottles. For regulated environments, look for temperature logging, audit trails and alarms. Refrigerant type, ambient conditions up to 32 C, noise and energy use also matter, along with the cooling method: compressor-based systems are typical, while thermoelectric cooling is used only for small, low-power units.
Full specifications
| Maximum speed | 3,000–5,000 rpm |
|---|---|
| Maximum RCF | approx. 3,500–5,500 x g |
| Bag capacity | 4–6 x 250–500 mL bags |
| Temperature range | -10 to 40 °C |
| Temperature accuracy | ±1 °C |
| Acceleration/braking profiles | 10 selectable, including soft start and no brake |
| Program memory | 30–99 methods |
| Data output | USB or RS-232 with alarm relay |
| Noise level | ≤ 65 dB(A) |
| Power supply | 220 V, 50/60 Hz, 1.5–2.5 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Whole blood component separation
- Platelet-rich plasma preparation
- Plasma and red cell concentrate production
- Blood center quality control
Key features
- Swing-out buckets hold 4 to 6 blood bags of 250 to 500 mL
- Temperature control from 4 C to 24 C supports platelet and red cell protocols
- Soft-start and no-brake stop profiles preserve component quality
- Data logging and alarm output support blood establishment traceability
- Stainless steel buckets resist disinfectants and bag leakage
Frequently asked questions about Blood Bank Refrigerated Centrifuge
Platelet-rich protocols are usually run at 20 to 24 C because cold exposure activates platelets and reduces viability. Red cell and plasma separation for storage may be run at 4 C. The centrifuge must therefore support both ranges with stable control.
Active braking disturbs the interface between red cells, buffy coat and plasma, reducing component yield and purity. A no-brake or coast stop lets the rotor spin down gradually, preserving the layered separation, at the cost of a longer cycle.
Remove buckets after use, wash with neutral detergent, disinfect with approved agents such as diluted sodium hypochlorite or 70 percent alcohol, rinse and dry. Inspect for cracks or corrosion, and follow the laboratory's biosafety spill procedure if a bag leaks.
Rotor friction with air heats the chamber, raising sample temperature by 10 to 20 C during long or high-speed runs. Refrigeration keeps proteins, enzymes, cells and nucleic acids from denaturing or losing activity. It also ensures repeatability by holding a consistent, documented temperature.
Most refrigerated centrifuges operate from -10 C to 40 C, and some models reach -20 C or 4 C minimum at maximum speed. Check the published temperature at full speed and ambient 25 C, since heat load at top speed can limit the minimum achievable setpoint.
Pre-cooling to 4 C usually takes 10 to 30 minutes depending on chamber volume and rotor mass. Floor-standing units with large rotors take longer. Pre-chilled rotors and a fast-cool function shorten the time and ensure the first sample starts at temperature.