Automated Affinity Purification System
自动化亲和纯化系统
- SKU PRP-0002
- Protein Purification
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Channels | 1–8 parallel |
|---|---|
| Resin volume | 0.2–5 mL per channel |
| Binding capacity | 5–40 mg target per mL resin (resin dependent) |
| Flow rate | 0.1–10 mL/min per channel |
| Maximum pressure | approx. 0.5 MPa |
| Sample volume | 1–500 mL (loop or direct load) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1057>, Ph. Eur. 2.2.29, Ph. Eur. 2.2.30
What is the Automated Affinity Purification System?
An automated affinity purification system captures tagged or antibody-based targets on affinity resin inside a programmable instrument, performing load, wash, elution and cleaning steps automatically for 1 to 8 samples in parallel.
What is the Automated Affinity Purification System?
An automated affinity purification system captures tagged or antibody-based targets on affinity resin inside a programmable instrument, performing load, wash, elution and cleaning steps automatically for 1 to 8 samples in parallel.
Overview
The instrument holds a column or cartridge pre-packed with affinity resin for each channel and drives buffers through it with syringe or peristaltic pumps. A typical method loads clarified lysate or supernatant, washes with several column volumes of buffer, elutes with a competing ligand or low-pH buffer, and neutralises the eluate where the resin requires it. Sensors monitor pressure and air detection to stop a channel that has run dry or blocked, and the software records volumes, flow rates and peak data for each channel independently. Capacity per run depends on resin volume, typically 0.2–5 mL, with binding capacities of 5–40 mg target protein per millilitre of resin for protein A and nickel resins. Automated operation shortens hands-on time and improves consistency between samples.
How does it work?
Chromatographic purification separates proteins by differences in a specific property. In affinity chromatography, a ligand such as immobilised nickel for histidine tags, glutathione for GST tags or protein A for antibodies retains the target while other proteins wash through, and a competing agent or a pH shift elutes it. Ion exchange uses charged resins so that proteins bind according to net charge at a chosen pH and elute under a salt gradient. Hydrophobic interaction chromatography binds proteins in high-salt buffers and elutes them as salt decreases. Size exclusion separates by hydrodynamic radius, with large molecules eluting first, which makes it useful for aggregate removal and buffer exchange. Magnetic bead methods bind the target on functionalised particles and collect them with a magnet, allowing parallel small-scale purification. Throughout, detectors measure absorbance at 280 nm and conductivity, and fractions are collected by peak.
What are the key features?
- One to eight parallel channels with independent pump control
- Pre-packed affinity cartridges for tag or antibody capture
- Programmable load, wash, elution and neutralisation steps
- Pressure and air sensors to stop blocked or dry channels
- Per-channel run logs with volumes and peak data
- Automated cleaning and storage routines between runs
What are the technical specifications?
A typical automated affinity purification system configuration offers channels of 1–8 parallel, resin volume of 0.2–5 mL per channel, binding capacity of 5–40 mg target per mL resin (resin dependent), flow rate of 0.1–10 mL/min per channel, maximum pressure of approx. 0.5 MPa and sample volume of 1–500 mL (loop or direct load). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Affinity Purification System is used in his-tagged recombinant protein purification, antibody capture from cell culture supernatant, GST and streptavidin tag purification and parallel screening of expression conditions. Across the wider Protein Purification class, laboratories also deploy it for recombinant protein purification for analysis, antibody purification from culture supernatant and aggregate and fragment removal before testing.
Which standards and certifications apply?
Relevant standards and methods include USP <1057>, Ph. Eur. 2.2.29, Ph. Eur. 2.2.30, IEC 61010-1, ISO 17025 and 21 CFR Part 11. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Maintain the system at a stable temperature, either at ambient with buffer equilibration or in a cold cabinet for labile proteins. Filter and degas all buffers to prevent pump damage and baseline noise, and choose buffers compatible with the resin and the downstream assay. Sanitise or clean-in-place the flow path between different proteins to avoid cross-contamination, and store columns in the recommended preservative. Monitor pressure throughout the run, because resin compression or a blocked line shows up first as rising pressure and then as distorted peaks. Keep tubing volumes small to limit peak broadening. Validate linearity, precision and carry-over before use in quality control, and retain chromatograms, gradients and fraction records so that a purification can be reproduced or investigated later.
How do I select the right Automated Affinity Purification System?
Select an automated affinity system when several tagged or antibody samples must be purified in parallel with consistent conditions, or when low-pH elution needs controlled neutralisation. Specify channel count, resin volume and capacity, flow rate, sample and elution volumes and the cartridge formats supported.
How does it compare with other Protein Purification variants?
Match the purification mode to the property you will exploit: a tag or known binding partner points to affinity chromatography, charge differences to ion exchange, salt-dependent hydrophobicity to hydrophobic interaction, and size differences to size exclusion. Then decide on scale and automation. Magnetic bead instruments suit parallel screening of 8–96 small samples where yield optimisation matters. Fast protein liquid chromatography systems with gradient pumps and fraction collectors handle method development and preparative work up to tens of milligrams per run. For screening many conditions quickly, perfusion chromatography allows short cycles at high flow rates. Check pressure rating, flow rate range, column and resin compatibility, gradient accuracy, fraction collector capacity and whether the software records methods and runs for traceability.
Full specifications
| Channels | 1–8 parallel |
|---|---|
| Resin volume | 0.2–5 mL per channel |
| Binding capacity | 5–40 mg target per mL resin (resin dependent) |
| Flow rate | 0.1–10 mL/min per channel |
| Maximum pressure | approx. 0.5 MPa |
| Sample volume | 1–500 mL (loop or direct load) |
| Elution volume | 0.5–10 mL |
| Detection | UV at 280 nm optional, pressure and air sensors standard |
| Program storage | Multiple methods with per-channel logs |
| Dimensions (W x D x H) | approx. 400 x 450 x 400 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- His-tagged recombinant protein purification
- Antibody capture from cell culture supernatant
- GST and streptavidin tag purification
- Parallel screening of expression conditions
Key features
- One to eight parallel channels with independent pump control
- Pre-packed affinity cartridges for tag or antibody capture
- Programmable load, wash, elution and neutralisation steps
- Pressure and air sensors to stop blocked or dry channels
- Per-channel run logs with volumes and peak data
- Automated cleaning and storage routines between runs
Frequently asked questions about Automated Affinity Purification System
Capacity depends on resin volume and binding capacity. A 1 mL protein A cartridge typically binds 5–40 mg of antibody, while a similar nickel cartridge binds 5–30 mg of histidine-tagged protein, depending on resin type and target.
Low-pH elution releases the target but can denature acid-sensitive proteins if they remain in the acidic buffer. Automatically adding a neutralising buffer immediately after elution keeps the protein in a stable pH range and improves recovery of active material.
Many affinity cartridges can be reused for several runs with the same sample type after sanitisation, as specified by the supplier. Reuse across different proteins risks carry-over, so dedicated cartridges are recommended when sensitivity of detection is high.
If the target carries a tag, start with affinity chromatography because it usually gives the highest purity in one step. If no tag is available, use ion exchange or hydrophobic interaction based on the protein's charge and hydrophobicity, followed by size exclusion for polishing.
A UV detector at 280 nm measures protein concentration in the eluate, and a conductivity monitor tracks the salt gradient. Together they show when the target elutes and allow fractions to be pooled, which is then confirmed by electrophoresis or activity assay.
Affinity purification removes most impurities but leaves aggregates, fragments and buffer components. Size exclusion separates molecules by hydrodynamic radius, so it removes aggregates and simultaneously exchanges the sample into the final formulation buffer.
Related models