Perfusion Chromatography System
灌注层析系统
- SKU PRP-0005
- Protein Purification
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Linear velocity | up to 1,000 cm/h |
|---|---|
| Column length | 30–100 mm |
| Cycle time | approx. 2–10 min for bind-and-elute |
| Maximum pressure | approx. 1–2 MPa |
| Particle size | approx. 20–60 µm |
| Binding capacity | comparable to conventional media at high flow |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1057>, Ph. Eur. 2.2.29, Ph. Eur. 2.2.30
What is the Perfusion Chromatography System?
A perfusion chromatography system uses rigid particles with large through-pores so that mobile phase flows through the beads rather than around them, allowing high flow rates and short cycles. It is chosen for rapid screening of purification conditions and for fast polishing steps.
What is the Perfusion Chromatography System?
A perfusion chromatography system uses rigid particles with large through-pores so that mobile phase flows through the beads rather than around them, allowing high flow rates and short cycles. It is chosen for rapid screening of purification conditions and for fast polishing steps.
Overview
Conventional chromatography resins rely on diffusion into pores, which limits flow rate because mass transfer becomes the bottleneck. Perfusion media contain both through-pores and diffusive pores, so solutes reach binding sites largely by convection and can be captured at linear velocities several times higher than on conventional media, often 5–20 times faster without losing capacity. That allows very short cycles for bind-and-elute steps, making the technique useful for screening binding and wash conditions, for capturing unstable proteins quickly and for rapid polishing. Columns are typically short, 30–100 mm, and pressures remain moderate. Because residence time is short, gradient volumes must be scaled accordingly, and optimisation work is usually needed to translate methods to conventional resins for scale-up.
How does it work?
Chromatographic purification separates proteins by differences in a specific property. In affinity chromatography, a ligand such as immobilised nickel for histidine tags, glutathione for GST tags or protein A for antibodies retains the target while other proteins wash through, and a competing agent or a pH shift elutes it. Ion exchange uses charged resins so that proteins bind according to net charge at a chosen pH and elute under a salt gradient. Hydrophobic interaction chromatography binds proteins in high-salt buffers and elutes them as salt decreases. Size exclusion separates by hydrodynamic radius, with large molecules eluting first, which makes it useful for aggregate removal and buffer exchange. Magnetic bead methods bind the target on functionalised particles and collect them with a magnet, allowing parallel small-scale purification. Throughout, detectors measure absorbance at 280 nm and conductivity, and fractions are collected by peak.
What are the key features?
- Rigid perfusion particles with through-pores and diffusive pores
- Linear velocities several times higher than conventional resins
- Short cycles of a few minutes for bind-and-elute steps
- Short columns of 30–100 mm with moderate back pressure
- Suitable for unstable proteins that need fast capture
- Compatible with screening formats and multi-column operation
What are the technical specifications?
A typical perfusion chromatography system configuration offers linear velocity of up to 1,000 cm/h, column length of 30–100 mm, cycle time of approx. 2–10 min for bind-and-elute, maximum pressure of approx. 1–2 MPa, particle size of approx. 20–60 µm and binding capacity of comparable to conventional media at high flow. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Perfusion Chromatography System is used in rapid screening of binding and wash conditions, fast capture of unstable or protease-sensitive proteins, high-throughput purification in process development and quick polishing before analysis. Across the wider Protein Purification class, laboratories also deploy it for recombinant protein purification for analysis, antibody purification from culture supernatant and aggregate and fragment removal before testing.
Which standards and certifications apply?
Relevant standards and methods include USP <1057>, Ph. Eur. 2.2.29, Ph. Eur. 2.2.30, IEC 61010-1, ISO 17025 and 21 CFR Part 11. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Maintain the system at a stable temperature, either at ambient with buffer equilibration or in a cold cabinet for labile proteins. Filter and degas all buffers to prevent pump damage and baseline noise, and choose buffers compatible with the resin and the downstream assay. Sanitise or clean-in-place the flow path between different proteins to avoid cross-contamination, and store columns in the recommended preservative. Monitor pressure throughout the run, because resin compression or a blocked line shows up first as rising pressure and then as distorted peaks. Keep tubing volumes small to limit peak broadening. Validate linearity, precision and carry-over before use in quality control, and retain chromatograms, gradients and fraction records so that a purification can be reproduced or investigated later.
How do I select the right Perfusion Chromatography System?
Select a perfusion chromatography system when short cycles and high flow rates matter more than the very high resolution of conventional resins, such as when screening many conditions or capturing labile proteins quickly. Specify linear velocity, column dimensions, chemistry options and pressure limits.
How does it compare with other Protein Purification variants?
Match the purification mode to the property you will exploit: a tag or known binding partner points to affinity chromatography, charge differences to ion exchange, salt-dependent hydrophobicity to hydrophobic interaction, and size differences to size exclusion. Then decide on scale and automation. Magnetic bead instruments suit parallel screening of 8–96 small samples where yield optimisation matters. Fast protein liquid chromatography systems with gradient pumps and fraction collectors handle method development and preparative work up to tens of milligrams per run. For screening many conditions quickly, perfusion chromatography allows short cycles at high flow rates. Check pressure rating, flow rate range, column and resin compatibility, gradient accuracy, fraction collector capacity and whether the software records methods and runs for traceability.
Full specifications
| Linear velocity | up to 1,000 cm/h |
|---|---|
| Column length | 30–100 mm |
| Cycle time | approx. 2–10 min for bind-and-elute |
| Maximum pressure | approx. 1–2 MPa |
| Particle size | approx. 20–60 µm |
| Binding capacity | comparable to conventional media at high flow |
| Chemistry options | Ion exchange, affinity and hydrophobic interaction |
| Detection | UV at 280 nm with conductivity monitoring |
| Number of columns | 1–8 in parallel screening configurations |
| Dimensions (W x D x H) | approx. 600 x 500 x 500 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Rapid screening of binding and wash conditions
- Fast capture of unstable or protease-sensitive proteins
- High-throughput purification in process development
- Quick polishing before analysis
Key features
- Rigid perfusion particles with through-pores and diffusive pores
- Linear velocities several times higher than conventional resins
- Short cycles of a few minutes for bind-and-elute steps
- Short columns of 30–100 mm with moderate back pressure
- Suitable for unstable proteins that need fast capture
- Compatible with screening formats and multi-column operation
Frequently asked questions about Perfusion Chromatography System
Mobile phase flows through large pores inside each particle rather than only around it, so solute transport to binding sites is largely convective instead of diffusive. Higher flow rates can therefore be used without losing capacity.
Not directly. Residence time, gradient volume and bed height differ, so optimisation is usually required when transferring a method from a perfusion medium to a conventional resin or vice versa. Scale-up should be confirmed by comparability runs.
Purity is usually maintained because binding capacity is preserved, but wash steps may be less effective if contact time is very short. Lengthening the wash or lowering the flow rate during wash can restore clearance of weakly bound impurities.
If the target carries a tag, start with affinity chromatography because it usually gives the highest purity in one step. If no tag is available, use ion exchange or hydrophobic interaction based on the protein's charge and hydrophobicity, followed by size exclusion for polishing.
A UV detector at 280 nm measures protein concentration in the eluate, and a conductivity monitor tracks the salt gradient. Together they show when the target elutes and allow fractions to be pooled, which is then confirmed by electrophoresis or activity assay.
Affinity purification removes most impurities but leaves aggregates, fragments and buffer components. Size exclusion separates molecules by hydrodynamic radius, so it removes aggregates and simultaneously exchanges the sample into the final formulation buffer.
Related models