DNA Shearing and Fragmentation System
DNA 剪切与片段化系统
- SKU MOP-0003
- Molecular Processing
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Fragmentation method | Hydrodynamic, acoustic or enzymatic |
|---|---|
| Target fragment size | 150–1,500 bp (method dependent) |
| DNA input range | 1 ng–10 µg |
| Samples per run | 1–8 (acoustic), 1 (hydrodynamic) |
| Processing time | 1–15 min |
| Temperature control | Typically 4–20 °C for shearing |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 13485, ISO 20395, CLSI MM13
What is the DNA Shearing and Fragmentation System?
A DNA shearing and fragmentation system breaks long DNA into a controlled size range for short-read sequencing and library construction. It typically uses hydrodynamic, acoustic or enzymatic methods with highly reproducible results.
What is the DNA Shearing and Fragmentation System?
A DNA shearing and fragmentation system breaks long DNA into a controlled size range for short-read sequencing and library construction. It typically uses hydrodynamic, acoustic or enzymatic methods with highly reproducible results.
Overview
A DNA shearing and fragmentation system reduces high-molecular-weight DNA to fragments of a chosen size. Hydrodynamic shearing forces DNA through a narrow aperture at controlled pressure, giving a reproducible size distribution and requiring little sample handling. Acoustic shearing uses focused ultrasound to break DNA in a closed tube, which keeps the sample contained and allows several samples in one run. Enzymatic fragmentation with transposases or nucleases is faster and simpler but can introduce sequence bias. Users tune energy, time, pressure or enzyme amount to reach a target fragment size, then confirm the distribution by electrophoresis or fragment analysis. Fragmentation before library preparation improves sequencing efficiency, and the resulting ends may need repair before adapter ligation. Reproducibility depends on input DNA quality, exact energy settings and careful handling to avoid further degradation.
How does it work?
Molecular processing systems manipulate DNA and RNA through controlled chemistry and liquid handling. Extraction isolates nucleic acid from cells or samples by lysis followed by binding to silica membranes or magnetic beads, with washing to remove proteins and inhibitors and elution into a small volume. Quantification measures concentration and purity by ultraviolet absorbance or fluorescent dye binding, and integrity may be checked by electrophoresis or fragment analysis. Fragmentation breaks long DNA into a controlled size range by enzymatic digestion, sonication or hydrodynamic shearing, which is required before short-read sequencing. Library preparation then ligates adapters and barcodes and amplifies the fragments. Automation platforms coordinate these steps with precise pipetting, heating and magnetic separation, and software tracks samples, reagents and results with the traceability molecular workflows require.
What are the key features?
- Hydrodynamic, acoustic or enzymatic fragmentation
- Programmable target fragment size
- Closed-tube processing for containment
- Reproducible size distribution
- Compatible with downstream library preparation
What are the technical specifications?
A typical dna shearing and fragmentation system configuration offers fragmentation method of Hydrodynamic, acoustic or enzymatic, target fragment size of 150–1,500 bp (method dependent), DNA input range of 1 ng–10 µg, samples per run of 1–8 (acoustic), 1 (hydrodynamic), processing time of 1–15 min and temperature control of Typically 4–20 °C for shearing. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The DNA Shearing and Fragmentation System is used in next-generation sequencing library preparation, long-read and short-read workflows, shotgun metagenomics and genome and transcriptome projects. Across the wider Molecular Processing class, laboratories also deploy it for genomics and sequencing workflows, molecular diagnostics development and biopharmaceutical cell line characterization.
Which standards and certifications apply?
Relevant standards and methods include ISO 13485, ISO 20395, CLSI MM13, CLSI MM03, 21 CFR Part 11, ISO 15189 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Work in a unidirectional flow from extraction to amplification to prevent amplicon contamination, and use separate areas and pipettes for each stage. Clean benches and equipment with the recommended agents and include no-template controls to detect contamination. Store reagents within their specified temperature range and check lot-to-lot performance when methods are validated. Monitor nucleic acid purity ratios and integrity, because inhibitors carried into amplification cause false negatives. Keep extraction and library preparation methods version controlled, and record reagent lot numbers with each batch. For clinical or regulated use, validate against reference methods and confirm that software provides the required audit trails and data security.
How do I select the right DNA Shearing and Fragmentation System?
Choose a fragmentation system from the target fragment size, the sample number and your containment needs. In an RFQ specify the method, achievable size range, input range, throughput, processing time and the consumables and size-confirmation tools supplied.
How does it compare with other Molecular Processing variants?
Match the system to the sample type, throughput and downstream application. For extraction, confirm the sample matrices supported, the input range, elution volume and the yield and purity achievable for your targets, and whether magnetic bead or membrane chemistry fits your workflow. For quantification, choose ultraviolet absorbance for broad concentration ranges or fluorescence for higher sensitivity with small amounts of DNA or RNA. For fragmentation, define the target insert size and the acceptable size distribution. For library preparation, check compatibility with your sequencing platform and read length, the number of samples per run and the barcode options. Across the category, verify automation level, cross-contamination controls, reagent formats, software traceability and the validation documentation required.
Full specifications
| Fragmentation method | Hydrodynamic, acoustic or enzymatic |
|---|---|
| Target fragment size | 150–1,500 bp (method dependent) |
| DNA input range | 1 ng–10 µg |
| Samples per run | 1–8 (acoustic), 1 (hydrodynamic) |
| Processing time | 1–15 min |
| Temperature control | Typically 4–20 °C for shearing |
| Consumables | Single-use apertures or tubes |
| Size confirmation | Electrophoresis or fragment analyzer |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Next-generation sequencing library preparation
- Long-read and short-read workflows
- Shotgun metagenomics
- Genome and transcriptome projects
Key features
- Hydrodynamic, acoustic or enzymatic fragmentation
- Programmable target fragment size
- Closed-tube processing for containment
- Reproducible size distribution
- Compatible with downstream library preparation
Frequently asked questions about DNA Shearing and Fragmentation System
Acoustic shearing suits multiple samples and containment, hydrodynamic shearing gives tight, reproducible distributions from a single sample, and enzymatic fragmentation is fastest and simplest but may add bias. The target library type and input amount usually decide.
Run a sample on an agarose gel or a fragment analyzer and compare the size distribution with the target window. The measured mean size, spread and presence of high-molecular-weight material indicate whether adjustments to energy, time or enzyme amount are needed.
Fragmentation depends on the starting molecule size distribution, so degraded or high-salt input gives inconsistent results. Clean, high-molecular-weight DNA at a known concentration produces reproducible fragment sizes and better library yield.
It prepares nucleic acids for downstream analysis by extracting, quantifying, fragmenting and building libraries from samples. Laboratories use it for sequencing, molecular diagnostics, microbial detection and biopharmaceutical characterization where results depend on clean, well-quantified DNA or RNA.
Magnetic bead methods scale easily to plates and automation and handle many sample types, while silica membranes in spin columns often give higher concentration from small volumes. The choice depends on sample matrix, throughput, elution volume and the yield your assay requires.
For DNA, a ratio of absorbance at 260 to 280 nm near 1.8 is common, and near 2.0 for RNA, with 260 to 230 nm ratios above about 1.8 to 2.0 indicating low carry-over of salts and inhibitors. Purity requirements depend on the downstream method.
Related models