Tangential Flow Filtration System
切向流过滤系统
- SKU PPU-0004
- Protein Purification
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- USP <665> material documentation (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Membrane area | 0.1–50 m² |
|---|---|
| Molecular weight cutoff | 3–1,000 kDa |
| Transmembrane pressure | Up to 0.3–0.6 MPa |
| Crossflow rate | 1–15 L/min per m² (module dependent) |
| Concentration factor | Up to 20–50 fold |
| Module type | Cassette or hollow fibre |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1050>, USP <661>, ICH Q7
What is the Tangential Flow Filtration System?
A tangential flow filtration system concentrates and buffer-exchanges protein solutions while flowing across a membrane rather than through it. It is used for harvest clarification, protein concentration and diafiltration in routine bioprocessing.
What is the Tangential Flow Filtration System?
A tangential flow filtration system concentrates and buffer-exchanges protein solutions while flowing across a membrane rather than through it. It is used for harvest clarification, protein concentration and diafiltration in routine bioprocessing.
Overview
A tangential flow filtration system pumps the process stream across the surface of a membrane so that retained molecules stay in circulation while solvent and small solutes pass through as permeate. Because flow is parallel to the membrane, fouling is slower than in dead-end filtration and high concentration factors are possible. Cassettes or hollow-fibre modules are selected by molecular weight cutoff, and the system controls transmembrane pressure, crossflow rate and permeate flow to protect the protein from shear and concentration polarization. Operations include concentration, diafiltration to exchange buffer, and clarification of harvested fluid. In-line sensors for pressure, ultraviolet absorbance and conductivity support endpoint decisions, and the system records volumes, pressures and flow rates. Membrane area, module format and pump sizing are set from the volumetric throughput and the target concentration.
How does it work?
Protein purification systems separate a target protein from host-cell proteins, nucleic acids, aggregates and process impurities by exploiting differences in binding, charge, hydrophobicity or size. A typical train begins with clarification by centrifugation or filtration, then capture chromatography, often affinity, which binds the target strongly and allows most impurities to flow through. Low-pH or other elution releases the product, which is then neutralized and further purified by ion exchange, hydrophobic interaction or multimodal chromatography, and polishing by size-exclusion or a second ion-exchange step removes aggregates and residual impurities. Tangential flow filtration concentrates the pool and exchanges it into the formulation buffer. Pumps, valves, detectors and software control flow rate, gradients, pooling and cleaning, and record the chromatogram and batch data.
What are the key features?
- Flow across the membrane limits fouling
- Cassette or hollow-fibre modules by molecular weight cutoff
- Control of transmembrane pressure and crossflow
- Concentration, diafiltration and clarification modes
- In-line pressure, UV and conductivity monitoring
What are the technical specifications?
A typical tangential flow filtration system configuration offers membrane area of 0.1–50 m², molecular weight cutoff of 3–1,000 kDa, transmembrane pressure of Up to 0.3–0.6 MPa, crossflow rate of 1–15 L/min per m² (module dependent), concentration factor of Up to 20–50 fold and module type of Cassette or hollow fibre. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Tangential Flow Filtration System is used in protein concentration, buffer exchange and diafiltration, harvest clarification and viral vector and plasmid processing. Across the wider Protein Purification class, laboratories also deploy it for monoclonal antibody purification, recombinant protein purification and vaccine antigen purification.
Which standards and certifications apply?
Relevant standards and methods include USP <1050>, USP <661>, ICH Q7, ICH Q11, EU GMP Annex 1, 21 CFR Part 11 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and USP <665> material documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Maintain resins according to the manufacturer's cleaning-in-place and storage instructions, and track cycle numbers against the validated lifetime. Verify column packing with an asymmetry and plate-count test before use and record it. Calibrate pumps, detectors, pH and conductivity sensors on schedule, and check that gradient performance meets method requirements. Use sanitary fittings, validated cleaning agents and documented cleaning verification for multi-product equipment. Control buffer preparation and microbial quality, since contamination reduces resolution and can introduce impurities. For regulated manufacture, review chromatogram data, pooling criteria and deviations as part of batch review, and confirm that software supports audit trails. Electrical safety follows IEC 61010-1.
How do I select the right Tangential Flow Filtration System?
Choose a tangential flow filtration system for concentration and buffer exchange where the product is shear sensitive or volumes are large. In an RFQ specify membrane area and cutoff, module format, transmembrane pressure and crossflow ranges, concentration targets, detection and recording needs.
How does it compare with other Protein Purification variants?
Select from the target molecule, expression level and scale. For capture, affinity resins give high selectivity and yield when a suitable ligand exists, while ion exchange or hydrophobic interaction suit cost-sensitive or ligand-free processes. Match column dimensions to the mass of product per batch and to the linear velocity the resin tolerates at the required cycle time. Choose the system format by scale: an automated laboratory system with method development software for development, a process skid with sanitary design and cleaning-in-place for production, and single-use flow paths for multi-product facilities. Determine the filtration area and membrane format required for clarification and concentration from the volumetric throughput. Confirm detection wavelengths, gradient and flow ranges, automation, data recording and the validation documentation you need.
Full specifications
| Membrane area | 0.1–50 m² |
|---|---|
| Molecular weight cutoff | 3–1,000 kDa |
| Transmembrane pressure | Up to 0.3–0.6 MPa |
| Crossflow rate | 1–15 L/min per m² (module dependent) |
| Concentration factor | Up to 20–50 fold |
| Module type | Cassette or hollow fibre |
| Detection | Pressure, UV, conductivity, flow |
| Material | Single-use capsule or stainless holder |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Protein concentration
- Buffer exchange and diafiltration
- Harvest clarification
- Viral vector and plasmid processing
Key features
- Flow across the membrane limits fouling
- Cassette or hollow-fibre modules by molecular weight cutoff
- Control of transmembrane pressure and crossflow
- Concentration, diafiltration and clarification modes
- In-line pressure, UV and conductivity monitoring
Frequently asked questions about Tangential Flow Filtration System
Concentration reduces the volume by removing permeate and retaining the product, raising its concentration. Diafiltration adds buffer while removing permeate at the same rate, exchanging the product into a new buffer without changing its concentration.
Area is sized from the volume to process, the target concentration factor and the permeate flux the membrane sustains for the product. A reasonable area keeps run time and pressure within the membrane's limits without excessive shear on the protein.
Crossflow keeps the membrane surface clear and limits concentration polarization, which otherwise reduces flux and can foul the membrane. It must be high enough for stable operation but not so high that shear damages the protein.
It captures and purifies recombinant proteins, antibodies and other biological products from harvested culture fluid. Chromatography steps bind the target and remove impurities, while filtration concentrates the product and places it in the formulation buffer for downstream use.
Capture is usually performed first, and affinity chromatography is preferred when a selective ligand exists because it removes most impurities in one step. Ion exchange or hydrophobic interaction capture is used when no affinity ligand is available or when cost and resin lifetime favor it.
Column diameter follows from the flow rate and the linear velocity the resin tolerates within the target cycle time, and bed height follows from the required resolution and dynamic binding capacity. Together they are set from the mass of product to process per batch.
Related models