Automated Nucleic Acid Extraction System
自动核酸提取系统
- SKU MOP-0001
- Molecular Processing
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- CE-IVD (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Sample throughput | 1–96 samples per run |
|---|---|
| Sample volume | 10 µL–1 mL (protocol dependent) |
| Elution volume | 30–200 µL, adjustable |
| Chemistry | Magnetic bead or silica membrane |
| Lysis heating | Ambient to 95 °C |
| Mixing | Magnetic or pipette mixing |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 13485, ISO 20395, CLSI MM13
What is the Automated Nucleic Acid Extraction System?
An automated nucleic acid extraction system isolates DNA or RNA from samples with magnetic beads or silica membranes and controlled liquid handling. It replaces manual spin-column work with highly reproducible, high-throughput purification.
What is the Automated Nucleic Acid Extraction System?
An automated nucleic acid extraction system isolates DNA or RNA from samples with magnetic beads or silica membranes and controlled liquid handling. It replaces manual spin-column work with highly reproducible, high-throughput purification.
Overview
An automated nucleic acid extraction system performs lysis, binding, washing and elution with a robotic platform, usually in a 96-well or strip format. Magnetic bead chemistry captures nucleic acid on particles that a magnet holds while liquids are aspirated and replaced, and silica membrane plates bind nucleic acid while vacuum or centrifugation drives liquid through. The instrument controls pipetting volumes, mixing, heating for lysis and elution, and the timing of each step, and many systems include onboard lysis heating, UV decontamination and bar-code reading of reagents and samples. Elution volumes can be small to concentrate the product, and protocols are optimized for blood, tissue, swabs, plants or environmental samples. Walk-away operation reduces operator variability, and software records the run and traces samples.
How does it work?
Molecular processing systems manipulate DNA and RNA through controlled chemistry and liquid handling. Extraction isolates nucleic acid from cells or samples by lysis followed by binding to silica membranes or magnetic beads, with washing to remove proteins and inhibitors and elution into a small volume. Quantification measures concentration and purity by ultraviolet absorbance or fluorescent dye binding, and integrity may be checked by electrophoresis or fragment analysis. Fragmentation breaks long DNA into a controlled size range by enzymatic digestion, sonication or hydrodynamic shearing, which is required before short-read sequencing. Library preparation then ligates adapters and barcodes and amplifies the fragments. Automation platforms coordinate these steps with precise pipetting, heating and magnetic separation, and software tracks samples, reagents and results with the traceability molecular workflows require.
What are the key features?
- Magnetic bead or silica membrane purification
- 96-well or strip-tube format for throughput
- Onboard lysis heating and mixing
- Programmable elution volume and protocol
- Barcode reading and run traceability
What are the technical specifications?
A typical automated nucleic acid extraction system configuration offers sample throughput of 1–96 samples per run, sample volume of 10 µL–1 mL (protocol dependent), elution volume of 30–200 µL, adjustable, chemistry of Magnetic bead or silica membrane, lysis heating of Ambient to 95 °C and mixing of Magnetic or pipette mixing. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Nucleic Acid Extraction System is used in molecular diagnostics sample preparation, genomics sample extraction, microbial and viral nucleic acid isolation and high-throughput screening laboratories. Across the wider Molecular Processing class, laboratories also deploy it for genomics and sequencing workflows, molecular diagnostics development and biopharmaceutical cell line characterization.
Which standards and certifications apply?
Relevant standards and methods include ISO 13485, ISO 20395, CLSI MM13, CLSI MM03, 21 CFR Part 11, ISO 15189 and IEC 61010-1. Certification candidates for this model are CE, ISO 13485 manufacturing and CE-IVD; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Work in a unidirectional flow from extraction to amplification to prevent amplicon contamination, and use separate areas and pipettes for each stage. Clean benches and equipment with the recommended agents and include no-template controls to detect contamination. Store reagents within their specified temperature range and check lot-to-lot performance when methods are validated. Monitor nucleic acid purity ratios and integrity, because inhibitors carried into amplification cause false negatives. Keep extraction and library preparation methods version controlled, and record reagent lot numbers with each batch. For clinical or regulated use, validate against reference methods and confirm that software provides the required audit trails and data security.
How do I select the right Automated Nucleic Acid Extraction System?
Choose an automated extraction system for reliable, reproducible, high-throughput purification. In an RFQ specify the sample types and volumes, throughput, chemistry, elution volume range, contamination controls, protocol flexibility and the traceability and validation features you require.
How does it compare with other Molecular Processing variants?
Match the system to the sample type, throughput and downstream application. For extraction, confirm the sample matrices supported, the input range, elution volume and the yield and purity achievable for your targets, and whether magnetic bead or membrane chemistry fits your workflow. For quantification, choose ultraviolet absorbance for broad concentration ranges or fluorescence for higher sensitivity with small amounts of DNA or RNA. For fragmentation, define the target insert size and the acceptable size distribution. For library preparation, check compatibility with your sequencing platform and read length, the number of samples per run and the barcode options. Across the category, verify automation level, cross-contamination controls, reagent formats, software traceability and the validation documentation required.
Full specifications
| Sample throughput | 1–96 samples per run |
|---|---|
| Sample volume | 10 µL–1 mL (protocol dependent) |
| Elution volume | 30–200 µL, adjustable |
| Chemistry | Magnetic bead or silica membrane |
| Lysis heating | Ambient to 95 °C |
| Mixing | Magnetic or pipette mixing |
| Contamination control | UV lamp, filter tips, sealed plate |
| Data output | LIMS or LIS export with sample tracking |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Molecular diagnostics sample preparation
- Genomics sample extraction
- Microbial and viral nucleic acid isolation
- High-throughput screening laboratories
Key features
- Magnetic bead or silica membrane purification
- 96-well or strip-tube format for throughput
- Onboard lysis heating and mixing
- Programmable elution volume and protocol
- Barcode reading and run traceability
Frequently asked questions about Automated Nucleic Acid Extraction System
Lysis releases nucleic acid, which binds to magnetic particles under the chosen buffer conditions. A magnet holds the particles against the tube or well wall while wash buffers and elution liquid are exchanged by pipetting, so no centrifugation is needed and the process suits automation.
A smaller elution volume gives a higher concentration but lower total yield, because some nucleic acid remains on the matrix. Choose the smallest volume that still meets your total mass requirement for the downstream assay, and confirm performance during validation.
Systems use filter tips, sealed plates, separate reagent positions and often ultraviolet decontamination between runs, while laboratories keep extraction and amplification areas physically separated. No-template controls confirm that reagents and environment remain clean.
It prepares nucleic acids for downstream analysis by extracting, quantifying, fragmenting and building libraries from samples. Laboratories use it for sequencing, molecular diagnostics, microbial detection and biopharmaceutical characterization where results depend on clean, well-quantified DNA or RNA.
Magnetic bead methods scale easily to plates and automation and handle many sample types, while silica membranes in spin columns often give higher concentration from small volumes. The choice depends on sample matrix, throughput, elution volume and the yield your assay requires.
For DNA, a ratio of absorbance at 260 to 280 nm near 1.8 is common, and near 2.0 for RNA, with 260 to 230 nm ratios above about 1.8 to 2.0 indicating low carry-over of salts and inhibitors. Purity requirements depend on the downstream method.
Related models