Manual Microplate Washer Manifold
手动洗板歧管
- SKU MIW-0001
- Microplate Washers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Channels | 8, 12 or 16 |
|---|---|
| Plate format | 96-well |
| Wash volume | 200–350 µL/well (operator set) |
| Residual volume | 5–10 µL/well (technique dependent) |
| Vacuum requirement | −30 to −60 kPa |
| Tube material | Stainless steel or PTFE |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-081, IEC 61326-1
What is the Manual Microplate Washer Manifold?
A manual microplate washer is a hand-operated manifold with aspirate and dispense tubes connected to a vacuum source and buffer reservoir. It is a low-cost option for laboratories running a few ELISA plates per week that can accept operator-dependent washing.
What is the Manual Microplate Washer Manifold?
A manual microplate washer is a hand-operated manifold with aspirate and dispense tubes connected to a vacuum source and buffer reservoir. It is a low-cost option for laboratories running a few ELISA plates per week that can accept operator-dependent washing.
Overview
This variant consists of an 8-, 12- or 16-channel manifold held by hand over the plate, a vacuum pump or aspirator with a waste trap, and gravity-fed or pressurized buffer supply. The operator positions the aspirate tubes in each row or column, releases vacuum, then fills with buffer. No programming, electronics or pumps are needed in the simplest models, and maintenance is limited to cleaning tubes. Its main limitations are operator-dependent residual volume and consistency, and it offers no soak or shake functions. Typical wash volume is adjustable by technique, often 200 to 350 microliters per well. It is suited to teaching laboratories, low-volume research or field settings, but is not recommended for regulated assays that need validated washing precision. Dedicated 8-channel units are the most common form.
How does it work?
A microplate washer uses a manifold carrying rows of dispense and aspirate tubes that enter the wells. Wash buffer is delivered from a reservoir by a peristaltic or diaphragm pump through the dispense tubes at a set volume and flow rate. The aspirate tubes, connected to a vacuum source, remove liquid, and their height is set to leave a low residual volume, often below 2 microliters per well in a 96-well plate. Programs combine multiple cycles with soak times, shaking, bottom washing and crosswise aspiration. Sensors detect clogged tubes and buffer level, and a waste bottle collects effluent. Dual-manifold designs allow two buffers, while magnetic bead washers hold beads with a magnet during aspiration. Precise alignment between manifold and well, particularly at 384-well density, is essential.
What are the key features?
- 8-, 12- or 16-channel manifold for row or column washing
- Connects to standard vacuum pump and waste trap
- No programming or electronics required in simple models
- Low purchase and maintenance cost
- Compatible with flat, U and V-bottom 96-well plates
- Removable tubes for cleaning and replacement
What are the technical specifications?
A typical manual microplate washer manifold configuration offers channels of 8, 12 or 16, plate format of 96-well, wash volume of 200–350 µL/well (operator set), residual volume of 5–10 µL/well (technique dependent), vacuum requirement of −30 to −60 kPa and tube material of Stainless steel or PTFE. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Manual Microplate Washer Manifold is used in teaching laboratory ELISA, low-volume research assays, field serology screening and plate cleanup in method development. Across the wider Microplate Washers class, laboratories also deploy it for ELISA wash cycles, cell-based assay medium exchange and magnetic bead immunoassay washing.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-081, IEC 61326-1, ANSI/SLAS 1-2004 to 4-2004, ISO 13485 (IVD use) and CLSI EP15-A3. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Prime the washer before each run and flush with deionized water at the end of the day to prevent salt crystallization and microbial growth. Run a weekly cleaning cycle with dilute disinfectant or sodium hypochlorite, following the manufacturer's guidance, and inspect manifold tubes for blockage. Verify dispense volume gravimetrically and residual volume with a dye method during qualification and at least annually. Treat effluent as biohazardous waste when samples are infectious, and use a vacuum trap with disinfectant. Use plate-specific alignment settings and replace tubing and seals according to schedule.
How do I select the right Manual Microplate Washer Manifold?
Choose this variant when plate volume is low and capital is limited. Consider an automatic washer for regulated assays or more than about 10 plates per week. In an RFQ specify channel count, plate format, tube material, vacuum pump and trap requirements and accessories such as a multichannel dispenser.
How does it compare with other Microplate Washers variants?
Choose a washer by plate format, throughput and assay sensitivity. Manual or semi-automatic manifolds suit low volume laboratories, while automatic washers with programmable protocols suit routine ELISA. Check residual volume per well, dispense precision, and the presence of bottom washing, soak and shake functions. For cell-based assays, select gentle dispensing with adjustable flow rate and offset aspiration to avoid cell detachment. For magnetic bead assays, confirm magnet compatibility. High-throughput laboratories need 384-well heads, stacker integration and fast cycle times. Consider capacity of buffer and waste bottles, tube cleaning routines, and ease of priming. Request residual volume and coefficient of variation data for your plate type.
Full specifications
| Channels | 8, 12 or 16 |
|---|---|
| Plate format | 96-well |
| Wash volume | 200–350 µL/well (operator set) |
| Residual volume | 5–10 µL/well (technique dependent) |
| Vacuum requirement | −30 to −60 kPa |
| Tube material | Stainless steel or PTFE |
| Buffer supply | Gravity or pressurized reservoir |
| Wash time per plate | 1–3 min per cycle (manual) |
| Power requirement | None (vacuum pump separate) |
| Waste collection | 1–2 L trap bottle |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Teaching laboratory ELISA
- Low-volume research assays
- Field serology screening
- Plate cleanup in method development
Key features
- 8-, 12- or 16-channel manifold for row or column washing
- Connects to standard vacuum pump and waste trap
- No programming or electronics required in simple models
- Low purchase and maintenance cost
- Compatible with flat, U and V-bottom 96-well plates
- Removable tubes for cleaning and replacement
Frequently asked questions about Manual Microplate Washer Manifold
Manual washing can give acceptable results for qualitative or low-volume work when done consistently, but residual volume and variability depend on the operator. Quantitative or regulated ELISA usually benefits from an automatic washer for reproducibility.
Most manifolds work with a modest vacuum of about minus 30 to minus 60 kilopascals drawn by a small diaphragm pump, with a trap bottle between the manifold and the pump to protect it from liquid and aerosols.
It is not advised for adherent cells because aspiration speed and tube position are uncontrolled and can detach monolayers. Gentle pipetting or an automatic washer with low flow and offset aspiration is preferred.
Residual volume is the liquid left in a well after aspiration. Low and consistent values, typically below 2 microliters in 96-well plates, dilute unbound conjugate less and give lower background and better well-to-well precision in ELISA.
Most ELISA protocols specify three to five wash cycles with 300 to 350 microliters per well of buffer containing a detergent such as Tween 20. Always follow the kit insert, and add soak time if background is high.
Some washers offer interchangeable manifolds or heads for each density, but tube spacing differs, so each format needs a matching manifold. Confirm plate height adjustment and aspiration alignment for each format before purchase.