Magnetic Bead Microplate Washer
磁珠洗板机
- SKU MIW-0004
- Microplate Washers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Plate format | 96-well (flat, U, V bottom) |
|---|---|
| Magnet type | Ring or bar magnet plate |
| Bead capture time | 30–120 s (programmable) |
| Dispense volume | 50–500 µL/well |
| Bead loss per cycle | < 2% (validated protocol) |
| Residual volume | < 5 µL/well |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-081, IEC 61326-1
What is the Magnetic Bead Microplate Washer?
A magnetic bead microplate washer holds paramagnetic beads in each well with a magnet plate while supernatant is aspirated and buffer is added. It is designed for bead-based immunoassays, nucleic acid extraction and multiplex assays where standard aspiration would remove beads.
What is the Magnetic Bead Microplate Washer?
A magnetic bead microplate washer holds paramagnetic beads in each well with a magnet plate while supernatant is aspirated and buffer is added. It is designed for bead-based immunoassays, nucleic acid extraction and multiplex assays where standard aspiration would remove beads.
Overview
This variant integrates a magnet plate that pulls paramagnetic beads to the well bottom or side wall, then aspirates and dispenses with controlled flow to avoid disturbing the pellet. Magnets may be ring, bar or pin style, and some washers can release the magnet automatically to resuspend beads with shaking between cycles. Dispense volume typically ranges from 50 to 500 microliters with aspirate positions offset from the bead pellet, and bead loss per cycle is kept below about 2 percent when optimized. The instrument can handle 96-well plates in flat, U and V-bottom formats and accepts programming for bead capture time, typically 30 to 120 seconds. It is used for multiplex bead assays and as a preparation step for sequencing libraries. Bead type and size affect capture efficiency, so validation with the exact beads is needed.
How does it work?
A microplate washer uses a manifold carrying rows of dispense and aspirate tubes that enter the wells. Wash buffer is delivered from a reservoir by a peristaltic or diaphragm pump through the dispense tubes at a set volume and flow rate. The aspirate tubes, connected to a vacuum source, remove liquid, and their height is set to leave a low residual volume, often below 2 microliters per well in a 96-well plate. Programs combine multiple cycles with soak times, shaking, bottom washing and crosswise aspiration. Sensors detect clogged tubes and buffer level, and a waste bottle collects effluent. Dual-manifold designs allow two buffers, while magnetic bead washers hold beads with a magnet during aspiration. Precise alignment between manifold and well, particularly at 384-well density, is essential.
What are the key features?
- Magnet plate captures paramagnetic beads during aspiration
- Programmable capture time from 30 to 120 seconds
- Offset aspiration and low flow dispensing protect bead pellets
- Automatic magnet release and shaking resuspend beads between cycles
- Bead loss typically below 2 percent per cycle when validated
- Compatible with flat, U and V-bottom 96-well plates
What are the technical specifications?
A typical magnetic bead microplate washer configuration offers plate format of 96-well (flat, U, V bottom), magnet type of Ring or bar magnet plate, bead capture time of 30–120 s (programmable), dispense volume of 50–500 µL/well, bead loss per cycle of < 2% (validated protocol) and residual volume of < 5 µL/well. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Magnetic Bead Microplate Washer is used in multiplex bead immunoassays, magnetic bead nucleic acid cleanup, sequencing library preparation, immunoprecipitation in plates and cell separation assays. Across the wider Microplate Washers class, laboratories also deploy it for ELISA wash cycles, cell-based assay medium exchange and magnetic bead immunoassay washing.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-081, IEC 61326-1, ANSI/SLAS 1-2004 to 4-2004, ISO 13485 (IVD use) and CLSI EP15-A3. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Prime the washer before each run and flush with deionized water at the end of the day to prevent salt crystallization and microbial growth. Run a weekly cleaning cycle with dilute disinfectant or sodium hypochlorite, following the manufacturer's guidance, and inspect manifold tubes for blockage. Verify dispense volume gravimetrically and residual volume with a dye method during qualification and at least annually. Treat effluent as biohazardous waste when samples are infectious, and use a vacuum trap with disinfectant. Use plate-specific alignment settings and replace tubing and seals according to schedule.
How do I select the right Magnetic Bead Microplate Washer?
Choose this variant when assays use paramagnetic beads and bead loss affects precision. A standard automatic washer is adequate for coated plates. In an RFQ specify bead diameter, plate type, capture time, wash volume and whether multiplex assay validation with your kit is required.
How does it compare with other Microplate Washers variants?
Choose a washer by plate format, throughput and assay sensitivity. Manual or semi-automatic manifolds suit low volume laboratories, while automatic washers with programmable protocols suit routine ELISA. Check residual volume per well, dispense precision, and the presence of bottom washing, soak and shake functions. For cell-based assays, select gentle dispensing with adjustable flow rate and offset aspiration to avoid cell detachment. For magnetic bead assays, confirm magnet compatibility. High-throughput laboratories need 384-well heads, stacker integration and fast cycle times. Consider capacity of buffer and waste bottles, tube cleaning routines, and ease of priming. Request residual volume and coefficient of variation data for your plate type.
Full specifications
| Plate format | 96-well (flat, U, V bottom) |
|---|---|
| Magnet type | Ring or bar magnet plate |
| Bead capture time | 30–120 s (programmable) |
| Dispense volume | 50–500 µL/well |
| Bead loss per cycle | < 2% (validated protocol) |
| Residual volume | < 5 µL/well |
| Shake function | Orbital, adjustable speed |
| Bead diameter range | 0.5–5 µm (typical) |
| Wash cycles | 1–20 |
| Program memory | ≥ 50 protocols |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Multiplex bead immunoassays
- Magnetic bead nucleic acid cleanup
- Sequencing library preparation
- Immunoprecipitation in plates
- Cell separation assays
Key features
- Magnet plate captures paramagnetic beads during aspiration
- Programmable capture time from 30 to 120 seconds
- Offset aspiration and low flow dispensing protect bead pellets
- Automatic magnet release and shaking resuspend beads between cycles
- Bead loss typically below 2 percent per cycle when validated
- Compatible with flat, U and V-bottom 96-well plates
Frequently asked questions about Magnetic Bead Microplate Washer
A standard washer aspirates all liquid and can pull beads into the waste. Magnetic washers first hold beads in place with a magnet, then aspirate off-center, so most beads stay in the well and assay signal is preserved.
Bead loss is measured by running labeled beads through a full wash protocol and comparing fluorescence or bead counts before and after washing, or by checking median fluorescence intensity shifts in a multiplex assay across wash cycles.
Yes. Smaller or less magnetic beads need longer capture time and stronger magnets, while larger beads settle faster. Test capture time and aspiration offset with your specific bead product to limit loss.
Residual volume is the liquid left in a well after aspiration. Low and consistent values, typically below 2 microliters in 96-well plates, dilute unbound conjugate less and give lower background and better well-to-well precision in ELISA.
Most ELISA protocols specify three to five wash cycles with 300 to 350 microliters per well of buffer containing a detergent such as Tween 20. Always follow the kit insert, and add soak time if background is high.
Some washers offer interchangeable manifolds or heads for each density, but tube spacing differs, so each format needs a matching manifold. Confirm plate height adjustment and aspiration alignment for each format before purchase.
Related models