384-Well High-Density Microplate Washer
384 孔高密度洗板机
- SKU MIW-0003
- Microplate Washers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Plate format | 384-well (1536-well optional) |
|---|---|
| Manifold | 96- or 384-needle |
| Dispense volume (384-well) | 5–100 µL/well |
| Dispense precision | CV < 4% at 50 µL |
| Residual volume | < 1 µL/well (384-well) |
| Z-axis resolution | 0.1 mm or finer |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-081, IEC 61326-1
What is the 384-Well High-Density Microplate Washer?
A 384-well high-density microplate washer uses fine-tipped manifolds aligned to small wells for precise aspiration and dispensing at 384-well and often 1536-well density. It suits screening and high-throughput laboratories that have moved assays to smaller volumes.
What is the 384-Well High-Density Microplate Washer?
A 384-well high-density microplate washer uses fine-tipped manifolds aligned to small wells for precise aspiration and dispensing at 384-well and often 1536-well density. It suits screening and high-throughput laboratories that have moved assays to smaller volumes.
Overview
High-density washers use manifolds with 96 or 384 needle pairs, sometimes dual-format heads convertible to 1536-well layouts, and motorized Z-axis positioning with micrometer resolution. Dispense volumes range from about 5 to 100 microliters per well with flow rates adjustable to avoid splashing, and aspirate pins are precisely centered to reach the bottom of narrow wells. Residual volumes are commonly below 1 microliter for 384-well plates. Accurate plate alignment sensors and plate skirt detection prevent crashes. Typical cycle times are less than 30 seconds for a full plate of three cycles. The system suits automation lines with stacker or robot integration and communicates through SiLA or vendor drivers. Higher cost, delicate pins and the need for clean, particulate-free buffers are the trade-offs, since pin clogging is a common failure.
How does it work?
A microplate washer uses a manifold carrying rows of dispense and aspirate tubes that enter the wells. Wash buffer is delivered from a reservoir by a peristaltic or diaphragm pump through the dispense tubes at a set volume and flow rate. The aspirate tubes, connected to a vacuum source, remove liquid, and their height is set to leave a low residual volume, often below 2 microliters per well in a 96-well plate. Programs combine multiple cycles with soak times, shaking, bottom washing and crosswise aspiration. Sensors detect clogged tubes and buffer level, and a waste bottle collects effluent. Dual-manifold designs allow two buffers, while magnetic bead washers hold beads with a magnet during aspiration. Precise alignment between manifold and well, particularly at 384-well density, is essential.
What are the key features?
- 96- or 384-needle manifolds for 384-well and optional 1536-well plates
- Micrometer-resolution Z-axis for precise aspiration height
- Residual volume commonly below 1 microliter per well in 384-well plates
- Adjustable dispense flow rate to prevent splashing and cell loss
- Plate skirt and alignment sensors prevent needle collisions
- Stacker and robot integration through vendor drivers or SiLA
What are the technical specifications?
A typical 384-well high-density microplate washer configuration offers plate format of 384-well (1536-well optional), manifold of 96- or 384-needle, dispense volume (384-well) of 5–100 µL/well, dispense precision of CV < 4% at 50 µL, residual volume of < 1 µL/well (384-well) and Z-axis resolution of 0.1 mm or finer. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The 384-Well High-Density Microplate Washer is used in high-throughput screening washes, low-volume 384-well ELISA, cell-based assay medium removal, homogeneous assay plate preparation and automation line integration. Across the wider Microplate Washers class, laboratories also deploy it for ELISA wash cycles, cell-based assay medium exchange and magnetic bead immunoassay washing.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-081, IEC 61326-1, ANSI/SLAS 1-2004 to 4-2004, ISO 13485 (IVD use) and CLSI EP15-A3. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Prime the washer before each run and flush with deionized water at the end of the day to prevent salt crystallization and microbial growth. Run a weekly cleaning cycle with dilute disinfectant or sodium hypochlorite, following the manufacturer's guidance, and inspect manifold tubes for blockage. Verify dispense volume gravimetrically and residual volume with a dye method during qualification and at least annually. Treat effluent as biohazardous waste when samples are infectious, and use a vacuum trap with disinfectant. Use plate-specific alignment settings and replace tubing and seals according to schedule.
How do I select the right 384-Well High-Density Microplate Washer?
Choose this variant when assays run in 384-well or higher plates and residual volume must stay very low. For 96-well only laboratories, a standard automatic washer is sufficient and more economical. In an RFQ specify plate formats, manifold density, residual volume target, buffer channels and automation interface requirements.
How does it compare with other Microplate Washers variants?
Choose a washer by plate format, throughput and assay sensitivity. Manual or semi-automatic manifolds suit low volume laboratories, while automatic washers with programmable protocols suit routine ELISA. Check residual volume per well, dispense precision, and the presence of bottom washing, soak and shake functions. For cell-based assays, select gentle dispensing with adjustable flow rate and offset aspiration to avoid cell detachment. For magnetic bead assays, confirm magnet compatibility. High-throughput laboratories need 384-well heads, stacker integration and fast cycle times. Consider capacity of buffer and waste bottles, tube cleaning routines, and ease of priming. Request residual volume and coefficient of variation data for your plate type.
Full specifications
| Plate format | 384-well (1536-well optional) |
|---|---|
| Manifold | 96- or 384-needle |
| Dispense volume (384-well) | 5–100 µL/well |
| Dispense precision | CV < 4% at 50 µL |
| Residual volume | < 1 µL/well (384-well) |
| Z-axis resolution | 0.1 mm or finer |
| Wash time (3 cycles) | < 30 s per plate |
| Buffer channels | 2–4 |
| Integration | Stacker, robot arm, SiLA |
| Program memory | ≥ 100 protocols |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-throughput screening washes
- Low-volume 384-well ELISA
- Cell-based assay medium removal
- Homogeneous assay plate preparation
- Automation line integration
Key features
- 96- or 384-needle manifolds for 384-well and optional 1536-well plates
- Micrometer-resolution Z-axis for precise aspiration height
- Residual volume commonly below 1 microliter per well in 384-well plates
- Adjustable dispense flow rate to prevent splashing and cell loss
- Plate skirt and alignment sensors prevent needle collisions
- Stacker and robot integration through vendor drivers or SiLA
Frequently asked questions about 384-Well High-Density Microplate Washer
Wells in a 384-well plate are only 3.3 millimeters wide at the top, so a misaligned needle can touch the well wall or scrape coatings and cells. Precise plate positioning and sensors ensure repeatable aspiration and protect the needles.
Filter buffers to remove particulates, flush with deionized water after each session, avoid letting buffer dry in the manifold, and clean needles periodically with a manufacturer-approved cleaning solution or ultrasonic bath.
Some models accept both formats with alternate heads or by processing each plate in quadrants, but performance and speed differ. Confirm supported formats and residual volume for each plate type in writing.
Residual volume is the liquid left in a well after aspiration. Low and consistent values, typically below 2 microliters in 96-well plates, dilute unbound conjugate less and give lower background and better well-to-well precision in ELISA.
Most ELISA protocols specify three to five wash cycles with 300 to 350 microliters per well of buffer containing a detergent such as Tween 20. Always follow the kit insert, and add soak time if background is high.
Some washers offer interchangeable manifolds or heads for each density, but tube spacing differs, so each format needs a matching manifold. Confirm plate height adjustment and aspiration alignment for each format before purchase.