Microplate Washer for Cell-Based Assays with Gentle Aspiration — product photo

Microplate Washer for Cell-Based Assays with Gentle Aspiration

细胞检测用温和吸液洗板机

  • SKU MIW-0005
  • Microplate Washers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Plate format96- and 384-well
Dispense flow rate2–50 µL/s adjustable
Dispense volume10–300 µL/well
Aspiration heightProgrammable, 0.1 mm steps
Residual volume5–20 µL/well (programmable)
Fluid pathSterilizable, autoclavable tubing
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-081, IEC 61326-1

What is the Microplate Washer for Cell-Based Assays with Gentle Aspiration?

A gentle-aspiration microplate washer for cell-based assays has low-flow dispensing and offset aspiration that keep adherent cell monolayers intact during medium exchange and washing. It is used for cell viability, immunofluorescence and cytotoxicity plates.

What is the Microplate Washer for Cell-Based Assays with Gentle Aspiration?

A gentle-aspiration microplate washer for cell-based assays has low-flow dispensing and offset aspiration that keep adherent cell monolayers intact during medium exchange and washing. It is used for cell viability, immunofluorescence and cytotoxicity plates.

Overview

This variant optimizes hydrodynamics to protect cells. Dispense flow is adjustable from slow trickle rates of a few microliters per second up to standard washing speeds, with angled or side-wall dispensing that avoids jetting onto the well bottom. Aspiration is offset from the center and set a fixed height above the cell layer, leaving a controlled residual volume of around 5 to 20 microliters so cells never dry. Speed of the aspirate pin movement and delays between dispense and aspirate are programmable. Some models have sterile fluid paths, UV or ethanol sterilization, and HEPA-filtered enclosures suitable for biosafety cabinets. Plate formats range from 96 to 384 wells, and optional heated buffer supply maintains temperature. Higher residual volume than ELISA washers means more wash cycles are needed to reach comparable dilution of unwanted reagents.

How does it work?

A microplate washer uses a manifold carrying rows of dispense and aspirate tubes that enter the wells. Wash buffer is delivered from a reservoir by a peristaltic or diaphragm pump through the dispense tubes at a set volume and flow rate. The aspirate tubes, connected to a vacuum source, remove liquid, and their height is set to leave a low residual volume, often below 2 microliters per well in a 96-well plate. Programs combine multiple cycles with soak times, shaking, bottom washing and crosswise aspiration. Sensors detect clogged tubes and buffer level, and a waste bottle collects effluent. Dual-manifold designs allow two buffers, while magnetic bead washers hold beads with a magnet during aspiration. Precise alignment between manifold and well, particularly at 384-well density, is essential.

What are the key features?

  • Adjustable low-flow dispensing protects adherent cell monolayers
  • Offset aspiration with programmable height leaves a controlled residual volume
  • Angled or side-wall dispensing avoids jetting onto the cell layer
  • Sterile fluid path with ethanol flush or UV options
  • Optional heated buffer supply for temperature-sensitive cells
  • Compact size suited to biosafety cabinet use

What are the technical specifications?

A typical microplate washer for cell-based assays with gentle aspiration configuration offers plate format of 96- and 384-well, dispense flow rate of 2–50 µL/s adjustable, dispense volume of 10–300 µL/well, aspiration height of Programmable, 0.1 mm steps, residual volume of 5–20 µL/well (programmable) and fluid path of Sterilizable, autoclavable tubing. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Microplate Washer for Cell-Based Assays with Gentle Aspiration is used in cell viability and cytotoxicity plates, immunofluorescence staining in microplates, medium exchange for adherent cells, high-content imaging sample preparation and transfection and reporter assay washes. Across the wider Microplate Washers class, laboratories also deploy it for ELISA wash cycles, cell-based assay medium exchange and magnetic bead immunoassay washing.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-081, IEC 61326-1, ANSI/SLAS 1-2004 to 4-2004, ISO 13485 (IVD use) and CLSI EP15-A3. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Prime the washer before each run and flush with deionized water at the end of the day to prevent salt crystallization and microbial growth. Run a weekly cleaning cycle with dilute disinfectant or sodium hypochlorite, following the manufacturer's guidance, and inspect manifold tubes for blockage. Verify dispense volume gravimetrically and residual volume with a dye method during qualification and at least annually. Treat effluent as biohazardous waste when samples are infectious, and use a vacuum trap with disinfectant. Use plate-specific alignment settings and replace tubing and seals according to schedule.

How do I select the right Microplate Washer for Cell-Based Assays with Gentle Aspiration?

Choose this variant when washing adherent or loosely attached cells where monolayer integrity decides data quality. It is unnecessary for coated ELISA plates. In an RFQ specify plate formats, flow rate range, required residual volume, sterility needs, heated buffer and whether the unit must fit inside a biosafety cabinet.

How does it compare with other Microplate Washers variants?

Choose a washer by plate format, throughput and assay sensitivity. Manual or semi-automatic manifolds suit low volume laboratories, while automatic washers with programmable protocols suit routine ELISA. Check residual volume per well, dispense precision, and the presence of bottom washing, soak and shake functions. For cell-based assays, select gentle dispensing with adjustable flow rate and offset aspiration to avoid cell detachment. For magnetic bead assays, confirm magnet compatibility. High-throughput laboratories need 384-well heads, stacker integration and fast cycle times. Consider capacity of buffer and waste bottles, tube cleaning routines, and ease of priming. Request residual volume and coefficient of variation data for your plate type.

Full specifications

Full specifications
Plate format96- and 384-well
Dispense flow rate2–50 µL/s adjustable
Dispense volume10–300 µL/well
Aspiration heightProgrammable, 0.1 mm steps
Residual volume5–20 µL/well (programmable)
Fluid pathSterilizable, autoclavable tubing
Sterilization70% ethanol flush; UV option
Buffer temperatureAmbient to 37 °C (optional heater)
Cycle time (1 wash)30–90 s per plate
Footprint≤ 40 × 40 cm (BSC compatible)

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Cell viability and cytotoxicity plates
  • Immunofluorescence staining in microplates
  • Medium exchange for adherent cells
  • High-content imaging sample preparation
  • Transfection and reporter assay washes

Key features

  • Adjustable low-flow dispensing protects adherent cell monolayers
  • Offset aspiration with programmable height leaves a controlled residual volume
  • Angled or side-wall dispensing avoids jetting onto the cell layer
  • Sterile fluid path with ethanol flush or UV options
  • Optional heated buffer supply for temperature-sensitive cells
  • Compact size suited to biosafety cabinet use

Frequently asked questions about Microplate Washer for Cell-Based Assays with Gentle Aspiration

High dispense flow, jetting onto the well bottom or aspirating too close to the monolayer creates shear that lifts cells. Using low flow, side-wall dispensing and offset, higher aspiration positions greatly reduces cell loss.

Request a quotation for the Microplate Washer for Cell-Based Assays with Gentle Aspiration