Inductively Coupled Plasma Optical Emission Spectrometer for Metal Assay
金属测定用电感耦合等离子体发射光谱仪
- SKU MET-0005
- Metal Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 165–800 nm |
|---|---|
| Detection limit | From about 1–10 µg/L in solution |
| Plasma power | 1.0–1.6 kW |
| Argon consumption | 10–20 L/min |
| Sample introduction | Nebuliser and spray chamber, autosampler |
| Elements per run | 20 or more |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E415, ASTM E1086, ASTM E1019
What is the Inductively Coupled Plasma Optical Emission Spectrometer for Metal Assay?
An inductively coupled plasma optical emission spectrometer measures trace and major elements in dissolved metal samples, separating the metal in acid first. It is used for certification work and unusual alloy systems.
What is the Inductively Coupled Plasma Optical Emission Spectrometer for Metal Assay?
An inductively coupled plasma optical emission spectrometer measures trace and major elements in dissolved metal samples, separating the metal in acid first. It is used for certification work and unusual alloy systems.
Overview
A weighed metal sample is dissolved in a suitable acid mixture, diluted to a known volume and introduced as an aerosol into an argon plasma at about 6000 to 8000 K, where atoms are excited and emit light at characteristic wavelengths. A polychromator with CCD detectors records the spectrum, and concentrations are calculated from calibrations prepared with matrix-matched standards, since the alloy matrix affects nebulisation and the plasma. The technique covers most elements from a few micrograms per litre upward, handles several elements in one run and is less sensitive to sample form than spark emission, which makes it useful for chips, turnings, powders and small parts. It is the reference route for trace elements, tramp elements and non-routine matrices, and is used to characterise and validate the reference standards that other techniques depend on.
How does it work?
Spark optical emission spectrometry is the workhorse for solid metal. An argon-shielded electric discharge vaporises and excites atoms at the sample surface, the emitted light is dispersed by a spectrometer, and intensities are converted to concentrations using calibrations built from certified reference materials of similar composition. X-ray fluorescence offers the same idea without the need for a conductive, flat surface: a beam excites inner-shell electrons, and the characteristic fluorescence identifies and quantifies elements, which makes handheld units useful for alloy sorting. Carbon, sulfur, oxygen, nitrogen and hydrogen are not accessible to optical emission at low levels and are determined by combustion or inert gas fusion: the sample melts in a crucible under a stream of oxygen or inert gas, gases are released and measured by infrared cells or thermal conductivity. Inductively coupled plasma optical emission spectrometry is used after acid dissolution for trace elements and for certification work. All these techniques depend on calibration, matrix matching and clean, representative samples.
What are the key features?
- Argon plasma torch with radio frequency generator
- CCD or CID detector with multi-element optics
- Acid digestion and matrix matched calibration
- Autosampler for long analytical runs
- Internal standard correction for drift
- Software for interference and background correction
What are the technical specifications?
A typical inductively coupled plasma optical emission spectrometer for metal assay configuration offers wavelength range of 165–800 nm, detection limit of From about 1–10 µg/L in solution, plasma power of 1.0–1.6 kW, argon consumption of 10–20 L/min, sample introduction of Nebuliser and spray chamber, autosampler and elements per run of 20 or more. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Inductively Coupled Plasma Optical Emission Spectrometer for Metal Assay is used in trace and tramp element determination in alloys, certification of reference and control materials, analysis of powders, chips and small components and verification of results obtained by spark emission. Across the wider Metal Analysis class, laboratories also deploy it for steel and alloy grade verification, foundry melt control and charge optimisation and positive material identification of installed parts.
Which standards and certifications apply?
Relevant standards and methods include ASTM E415, ASTM E1086, ASTM E1019, ASTM E1479, ISO 14284, ASTM E1806 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Everything depends on calibration and reference materials, so keep a set of certified standards covering each element range and renew them before they expire. Condition the sample surface correctly: machined for spark emission, flat and clean for X-ray fluorescence, uncontaminated chips for combustion. Reference the instrument daily with a control sample and confirm drift before releasing results. Maintain gas supplies at the specified purity, since moisture and oxygen in argon degrade spark stability, and check crucibles, electrodes, filters and reagents on a schedule. Control contamination between samples: clean the spark stand, change crucibles and use new tools. Radiation and laser safety programs, fume extraction for acid digestion and safe handling of compressed gases are part of normal operation, and records of calibration, verification and maintenance should travel with the results.
How do I select the right Inductively Coupled Plasma Optical Emission Spectrometer for Metal Assay?
Select the plasma spectrometer for trace elements, non-routine matrices and certification work, and check the detection limits for your target elements in your matrix. Specify digestion equipment, autosampler capacity, argon supply and the software features needed for interference correction.
How does it compare with other Metal Analysis variants?
Decide from the elements, the levels and the sample form. For production control of solid metal, spark optical emission gives fast multi-element results from a machined surface and is the usual choice, with the spectrometer configuration matched to the base metals and element ranges you analyse. Combustion and inert gas fusion instruments are required when carbon, sulfur, oxygen, nitrogen or hydrogen form part of the specification, and they need their own sample preparation and reference materials. Handheld X-ray fluorescence suits incoming inspection, alloy sorting and positive material identification on installed parts, but cannot measure carbon or low atomic number elements and needs careful radiation management. Inductively coupled plasma is preferred for trace and tramp elements, for non-routine matrices and for validating other methods. Check detection limits, the number of elements and channels, calibration standards available, argon or gas supply and service support before committing.
Full specifications
| Wavelength range | 165–800 nm |
|---|---|
| Detection limit | From about 1–10 µg/L in solution |
| Plasma power | 1.0–1.6 kW |
| Argon consumption | 10–20 L/min |
| Sample introduction | Nebuliser and spray chamber, autosampler |
| Elements per run | 20 or more |
| Digestion | Acid mixture per method |
| Data output | LAN, LIMS export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Trace and tramp element determination in alloys
- Certification of reference and control materials
- Analysis of powders, chips and small components
- Verification of results obtained by spark emission
Key features
- Argon plasma torch with radio frequency generator
- CCD or CID detector with multi-element optics
- Acid digestion and matrix matched calibration
- Autosampler for long analytical runs
- Internal standard correction for drift
- Software for interference and background correction
Frequently asked questions about Inductively Coupled Plasma Optical Emission Spectrometer for Metal Assay
The plasma accepts a liquid aerosol, so the metal must be brought into solution in a homogeneous form. The acid mixture depends on the alloy: aqua regia for many steels, hydrofluoric or perchloric additions for resistant grades, and specialised mixtures for titanium or superalloys.
The alloy matrix changes viscosity, nebulisation efficiency and plasma conditions, so standards containing similar amounts of the main elements keep the calibration valid. Internal standards are added to correct for remaining drift.
Spark emission is faster and does not need dissolution, but it needs solid, flat, conductive samples and is less suited to trace elements. Plasma emission accepts chips, powders and small parts and reaches lower detection limits in solution.
Spark optical emission spectrometry for solid metal, because it measures many elements quickly from a machined surface. Carbon, sulfur and dissolved gases are added by combustion or inert gas fusion analyzers, since optical emission cannot reach the required low levels.
Yes, for grades distinguished by elements from about magnesium upward, which covers most stainless and alloy steels, nickel alloys and copper alloys. Carbon, silicon and other light elements cannot be measured, so some grades require laboratory confirmation.
By combustion: a weighed sample burns with an accelerator in an oxygen stream in an induction furnace, and the carbon dioxide and sulfur dioxide released are measured with infrared cells. Results are reported in percent or in mg/kg for low levels.