Upright Reflected-Light Metallurgical Microscope
直立式反射光金相显微镜
- SKU MIP-0001
- Microscopy
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Magnification range | 50× to 1000× |
|---|---|
| Objective set | 5×, 10×, 20×, 50×, 100× |
| Illumination modes | Brightfield, darkfield, polarized, DIC |
| Light source | LED or halogen with intensity control |
| Stage travel | 75 × 50 mm with micrometers |
| Numerical aperture range | 0.12 to 0.90 depending on objective |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E3, ASTM E407, ASTM E112
What is the Upright Reflected-Light Metallurgical Microscope?
An upright reflected-light metallurgical microscope views polished and etched specimens from above with a full set of objectives and several illumination modes. It is the standard instrument for grain size and inclusion rating.
What is the Upright Reflected-Light Metallurgical Microscope?
An upright reflected-light metallurgical microscope views polished and etched specimens from above with a full set of objectives and several illumination modes. It is the standard instrument for grain size and inclusion rating.
Overview
The specimen sits on a mechanical stage and is illuminated through the objective, which also collects the reflected light. Objectives of 5× to 100× cover the range from an overview of the section to detailed examination of fine precipitates, and the eyepieces or camera add the final magnification. Brightfield reveals general structure after etching, darkfield highlights inclusions, cracks and porosity, polarized light differentiates anisotropic phases and can measure coating thickness on coated samples, and differential interference contrast shows relief and small height differences without etching. A mechanical stage with micrometer travel allows systematic traverses from surface to core for case-depth work, and a trinocular port accepts a camera. Kohler illumination and adjustable field and aperture diaphragms allow reproducible contrast settings, which are recorded with each result.
How does it work?
A metallurgical microscope illuminates the specimen from the same side as the objective, since metal is opaque, and the polished and etched surface reflects light back through the optical system. Contrast comes from differences in reflectivity between phases, from surface relief created by etching, and from scattering by inclusions and cracks. Objective numerical aperture determines resolution, and magnification should be chosen so that the features of interest occupy a reasonable fraction of the field, because empty magnification adds no detail. Illumination modes extend the range: brightfield for general structure, darkfield for inclusions and cracks, polarized light for anisotropic phases and coatings, and differential interference contrast for relief and small height differences. Stereo microscopes use separate light paths for each eye to give depth perception, which makes them suitable for fracture surfaces and weld profiles. Digital cameras and measuring software add quantitative output, such as grain size, coating thickness and defect dimensions.
What are the key features?
- Objectives from 5× to 100× with matched eyepieces
- Brightfield, darkfield, polarized and DIC modes
- Kohler illumination with field and aperture diaphragms
- Mechanical stage with micrometer travel
- Trinocular port for digital camera
- Reflected light path designed for opaque specimens
What are the technical specifications?
A typical upright reflected-light metallurgical microscope configuration offers magnification range of 50× to 1000×, objective set of 5×, 10×, 20×, 50×, 100×, illumination modes of Brightfield, darkfield, polarized, DIC, light source of LED or halogen with intensity control, stage travel of 75 × 50 mm with micrometers and numerical aperture range of 0.12 to 0.90 depending on objective. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Upright Reflected-Light Metallurgical Microscope is used in grain size and phase fraction measurement, inclusion and cleanliness rating, case depth and coating measurement and general microstructure examination of steels. Across the wider Microscopy class, laboratories also deploy it for grain size and inclusion rating of steels, weld and heat-affected zone examination and fracture surface and failure investigation.
Which standards and certifications apply?
Relevant standards and methods include ASTM E3, ASTM E407, ASTM E112, ASTM E45, ISO 643, ASTM E1951 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Clean lenses only with the recommended method, since immersion oils and abrasives damage coatings, and cover the instrument when not in use. Verify magnification and length calibration with a stage micrometer at each objective and after any change of camera or software, and keep a record with the results. Set illumination to a reproducible level, because contrast in reflected light depends strongly on lamp intensity and aperture settings, and note the objective and illumination mode in every report. Keep specimens clean and dry, store them in labelled containers, and use replicas rather than marking the component when examining installed parts. Service the illuminator, stage and focusing mechanism periodically, and check the camera sensor for dust that would appear as artefacts in images used for measurement, since a mistaken artefact can change a reported coating thickness.
How do I select the right Upright Reflected-Light Metallurgical Microscope?
Select the upright microscope for polished section work and choose the objective set and illumination options against the features you report, such as fine inclusions or coatings. Include a digital camera, stage micrometer and calibration slide in the order.
How does it compare with other Microscopy variants?
Choose the microscope type from what must be seen. Upright reflected-light instruments with a full objective set and multiple illumination modes handle polished sections, grain size and inclusion rating. Inverted stages are better for large or unmounted specimens. Stereo microscopes are the right tool for fracture surfaces, weld profiles, corrosion damage and assembly inspection, where depth and surface shape matter more than high magnification. Digital measuring microscopes suit dimensional work on small features, such as tool edges, holes, threads and coating cross-sections, where accuracy claims need to be supported by calibration. Portable microscopes serve on-site replica examination of installed plant. In every case, match the magnification range, numerical aperture and illumination modes to the features of interest, and budget for a stage micrometer, calibration slides and a camera whose resolution genuinely exceeds the detail the optics can deliver.
Full specifications
| Magnification range | 50× to 1000× |
|---|---|
| Objective set | 5×, 10×, 20×, 50×, 100× |
| Illumination modes | Brightfield, darkfield, polarized, DIC |
| Light source | LED or halogen with intensity control |
| Stage travel | 75 × 50 mm with micrometers |
| Numerical aperture range | 0.12 to 0.90 depending on objective |
| Camera port | Trinocular, C-mount |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Grain size and phase fraction measurement
- Inclusion and cleanliness rating
- Case depth and coating measurement
- General microstructure examination of steels
Key features
- Objectives from 5× to 100× with matched eyepieces
- Brightfield, darkfield, polarized and DIC modes
- Kohler illumination with field and aperture diaphragms
- Mechanical stage with micrometer travel
- Trinocular port for digital camera
- Reflected light path designed for opaque specimens
Frequently asked questions about Upright Reflected-Light Metallurgical Microscope
A 5× or 10× for overview and traverses, a 20× for general structure, and a 50× and 100× oil objective for fine inclusions and thin coatings. The 100× objective is only usable on well-prepared, flat specimens.
Apparent contrast and measured feature size depend on lamp intensity, aperture and diaphragm settings, so comparable images require the same conditions. Recording them allows another operator to reproduce an observation or a measurement.
No. Empty magnification enlarges the image without adding detail once the resolution limit set by numerical aperture is reached. Choose the magnification that resolves the feature and still shows enough field to be representative.
Metals are opaque, so transmitted illumination cannot pass through a polished section. Light is directed through the objective onto the specimen and reflected back, and contrast comes from differences in reflectivity and from surface relief.
Darkfield, because inclusions and voids scatter light and appear bright against a dark background, whereas they can be nearly invisible in brightfield if their reflectivity is similar to the matrix.
For fracture surfaces, weld profiles, corrosion pits and assembled parts, where three-dimensional shape and depth are important and high magnification with a polished, flat surface is not applicable.