Online Ion Analyzer
在线离子分析仪
- SKU IOM-0004
- Ion Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0.02–1000 mg/L (parameter dependent) |
|---|---|
| Accuracy | ±2% of reading |
| Response time | 1–5 min |
| Sample flow | 10–50 mL/min |
| Sample temperature | 5–40 °C |
| Analog output | 4-20 mA, isolated |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D1179, ISO 10359-1, EPA Method 9214
What is the Online Ion Analyzer?
An online ion analyzer continuously measures a selected ion in a flowing stream with an ion-selective electrode or colorimetric cell and sends 4-20 mA and relay signals to a control system. It is used for drinking water, wastewater and industrial process monitoring where results must be available without delay.
What is the Online Ion Analyzer?
An online ion analyzer continuously measures a selected ion in a flowing stream with an ion-selective electrode or colorimetric cell and sends 4-20 mA and relay signals to a control system. It is used for drinking water, wastewater and industrial process monitoring where results must be available without delay.
Overview
The analyzer draws a small sample flow, conditions it by filtration or sedimentation and mixes it with an ionic strength adjustment reagent before measurement in a flow cell with an ion-selective electrode. Automatic calibration and cleaning cycles, typically daily, maintain electrode performance, and reagent or standard reservoirs are sized for two to four weeks of unattended operation. Outputs include 4-20 mA for each measured ion, alarm relays for out-of-range conditions and Modbus or Profibus for direct connection to a plant control system. Enclosures are rated IP65 or better, and wetted parts are chosen for the sample chemistry, for example PVC or PTFE for fluoride streams. Response time is usually one to five minutes, including sample transport and conditioning. Data logging and trend display help operators follow treatment performance, and validation against grab samples confirms ongoing accuracy.
How does it work?
The measurement is potentiometric. An ion-selective electrode develops a potential that follows the Nernst equation, changing by about 59.16 mV per decade of activity at 25 degrees Celsius for a monovalent ion and 29.58 mV for a divalent ion. A stable reference electrode with a liquid junction completes the cell, and a high-impedance millivoltmeter reads the potential difference without drawing significant current. Because the electrode responds to activity rather than concentration, an ionic strength adjustment buffer is added to fix the activity coefficient; some buffers also adjust pH and release ions bound by complexing agents. The meter converts potential to concentration with a calibration curve from two to five standards, and temperature compensation corrects the slope using a built-in sensor. Below about 1 micromolar, results are less stable, so lower limits are set by the electrode and by the sample matrix.
What are the key features?
- Continuous ion measurement with automatic daily calibration and cleaning
- Sample conditioning with filtration and automatic ionic strength reagent dosing
- 4-20 mA outputs and alarm relays for each measured parameter
- Modbus or Profibus connection to plant control and SCADA systems
- Reagent and standard reservoirs sized for two to four weeks of operation
- IP65 or higher enclosure designed for wall or panel mounting
What are the technical specifications?
A typical online ion analyzer configuration offers measuring range of 0.02–1000 mg/L (parameter dependent), accuracy of ±2% of reading, response time of 1–5 min, sample flow of 10–50 mL/min, sample temperature of 5–40 °C and analog output of 4-20 mA, isolated. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Online Ion Analyzer is used in drinking water fluoride dosing control, wastewater ammonia and nitrate monitoring, power plant and boiler water control, industrial process stream monitoring and recirculating aquaculture systems. Across the wider Ion Meters class, laboratories also deploy it for drinking water fluoride monitoring, wastewater ammonia and nitrate testing and food and beverage sodium analysis.
Which standards and certifications apply?
Relevant standards and methods include ASTM D1179, ISO 10359-1, EPA Method 9214, APHA 4500-F− Standard Methods, GB/T 7484 and ASTM D3867. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Condition new electrodes as the manufacturer instructs, often by soaking in a dilute standard solution for several hours, and calibrate daily with standards that bracket the sample range. Add ionic strength adjustment buffer to samples and standards in the same proportion, and measure at a stable temperature because electrode slopes change with temperature. Do not let electrodes dry out; store fluoride and pH-sensitive membranes according to their specific instructions and keep reference junctions clean and filled. Verify performance with a check standard and monitor the slope in millivolts per decade, since slopes outside about 50 to 60 millivolts per decade for monovalent ions indicate ageing or contamination. Records of calibration, slope, verification and sample matrix should be retained for regulated work, and waste containing buffer and fluoride must be handled as chemical waste.
How do I select the right Online Ion Analyzer?
Select an online analyzer when results must be continuous and unattended, for example for dosing control or discharge compliance. It is not a substitute for a benchtop meter in method development. In an RFQ, specify the ion, measuring range, sample composition and temperature, required accuracy, output and communication type, reagent consumption and maintenance interval.
How does it compare with other Ion Meters variants?
Choose a benchtop meter when accuracy, documentation and multi-ion work matter, and a portable meter for field checks in surface water, aquaculture or plant streams. Multi-channel models suit laboratories running several electrodes or several ions in parallel, while online analyzers serve continuous monitoring of drinking water, wastewater or process streams with alarm and 4-20 mA outputs. If you measure fluoride every day in a defined matrix, a dedicated fluoride meter with matched electrode and buffer simplifies training and calibration. Compare the electrode range first, then meter resolution and accuracy in millivolts, temperature compensation, calibration points, electrode compatibility, GLP memory and data interfaces. Specify the ions, expected concentration range, sample matrix, required detection limit and any standards the method must follow.
Full specifications
| Measuring range | 0.02–1000 mg/L (parameter dependent) |
|---|---|
| Accuracy | ±2% of reading |
| Response time | 1–5 min |
| Sample flow | 10–50 mL/min |
| Sample temperature | 5–40 °C |
| Analog output | 4-20 mA, isolated |
| Digital interface | Modbus RTU/TCP, optional Profibus |
| Alarm relays | 2–4 programmable |
| Enclosure rating | IP65 or higher |
| Automatic calibration | Programmable, typically daily |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water fluoride dosing control
- Wastewater ammonia and nitrate monitoring
- Power plant and boiler water control
- Industrial process stream monitoring
- Recirculating aquaculture systems
Key features
- Continuous ion measurement with automatic daily calibration and cleaning
- Sample conditioning with filtration and automatic ionic strength reagent dosing
- 4-20 mA outputs and alarm relays for each measured parameter
- Modbus or Profibus connection to plant control and SCADA systems
- Reagent and standard reservoirs sized for two to four weeks of operation
- IP65 or higher enclosure designed for wall or panel mounting
Frequently asked questions about Online Ion Analyzer
Plan on a weekly visual check, reagent or standard replacement every two to four weeks, electrode cleaning or polishing monthly and a full service visit twice a year. Automatic calibration and cleaning reduce labour but do not replace inspection of tubing, pumps and the reference junction.
Differences come from sample conditioning, ionic strength reagent dosing ratio, temperature and the delay between grab sampling and analysis in the laboratory. Verify by measuring the grab sample with the same buffer ratio and electrode type, and correct the dosing or filtration set-up if a bias persists.
Multi-channel online analyzers exist for two or three ions, but each channel needs its own electrode, flow cell and reagent line. If the ions require different conditioning chemistry, separate analyzers or a sequential sampling valve with a single measuring cell are usually more practical.
An ion meter measures the activity or concentration of a specific ion in solution with an ion-selective electrode. Typical uses include fluoride in drinking water, ammonia and nitrate in wastewater, sodium in food, and chloride or calcium in process streams, reported in mol/L, mg/L or ppm.
Calibrate at the start of each working day, or before each batch when accuracy is critical. Use two or more standards that bracket the expected range, verify with an independent check standard, and recalibrate after any electrode change, membrane cleaning or large temperature shift.
Both are potentiometric instruments, but a pH meter converts glass electrode potential into pH units, while an ion meter offers selectable calibration curves and units for specific ions such as fluoride or nitrate. Many benchtop meters support both functions when fitted with the matching electrode.