Inverted Tissue Culture Microscope
倒置组织培养显微镜
- SKU INM-0003
- Inverted Microscopes
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Optical system | Infinite corrected |
|---|---|
| Magnification range | 40×–400× |
| Objectives | 4×, 10×, 20×, 40× long working distance |
| Eyepiece | 10× widefield |
| Working distance | Up to 8 mm |
| Stage | Fixed plate holder with inserts |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 8036, ISO 19012-1, ISO 9345-1
What is the Inverted Tissue Culture Microscope?
An inverted tissue culture microscope is configured for daily routine observation inside incubators and laminar flow cabinets. Its sealed optics and compact form support sterile cell-culture workflows in flasks and multi-well plates.
What is the Inverted Tissue Culture Microscope?
An inverted tissue culture microscope is configured for daily routine observation inside incubators and laminar flow cabinets. Its sealed optics and compact form support sterile cell-culture workflows in flasks and multi-well plates.
Overview
An inverted tissue culture microscope is optimised for the practical demands of cell culture: a compact stand that fits inside a laminar flow cabinet or incubator, sealed optics to resist humidity and cleaning agents, and a stage that accepts flasks, dishes and multi-well plates. Objectives are long working distance to look through vessel bases, and often have an anti-fungal coating for humid environments. Illumination is cool and intense enough for phase contrast, with minimal heat to protect cultures. The design keeps contamination risk low and allows frequent checks without removing samples from controlled conditions. Some models accept a camera for documentation.
How does it work?
An inverted microscope reverses the usual arrangement so the objective looks upward from beneath the stage while the light source and condenser sit above. The specimen remains in a flask, dish or multi-well plate, so it need not be transferred to a slide. Long working distance objectives focus through the plastic or glass base of the vessel. Transmitted brightfield and phase contrast provide morphology, while episcopic illumination through the objective allows fluorescence. Ambient conditions can be controlled with heated stages and carbon dioxide chambers. The design supports observations of living material, micromanipulation and time-lapse imaging without disturbing the specimen.
What are the key features?
- Compact stand fitting incubators and cabinets
- Sealed optics resistant to humidity and disinfectants
- Stage for flasks, dishes and multi-well plates
- Long working distance objectives, anti-fungal option
- Cool LED illumination for phase contrast
What are the technical specifications?
A typical inverted tissue culture microscope configuration offers optical system of Infinite corrected, magnification range of 40×–400×, objectives of 4×, 10×, 20×, 40× long working distance, eyepiece of 10× widefield, working distance of Up to 8 mm and stage of Fixed plate holder with inserts. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Inverted Tissue Culture Microscope is used in cell culture monitoring in incubators, sterile workflow observation, multi-well plate screening and stem-cell and primary culture work. Across the wider Inverted Microscopes class, laboratories also deploy it for live-cell and tissue culture microscopy, cell biology and stem-cell research and in vitro fertilisation and embryo work.
Which standards and certifications apply?
Relevant standards and methods include ISO 8036, ISO 19012-1, ISO 9345-1, ISO 8255-1 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the vessel base clean and free of condensation, which scatters light and blurs the image. For phase contrast, centre the annulus with the matching objective. Maintain temperature and gas conditions for live cells, and minimise light exposure to reduce phototoxicity and bleaching. Long working distance objectives are exposed to the sample and medium, so clean them gently and avoid immersion of non-immersion optics. Calibrate measurements for each objective and vessel thickness, and record the setup with images. Service the stage and focus mechanisms regularly for stable time-lapse work.
How do I select the right Inverted Tissue Culture Microscope?
Choose an inverted tissue culture microscope when observations must be made inside a cabinet or incubator or when resistance to humidity and disinfection matters. Confirm the footprint fits the cabinet, that the stage accepts the vessel formats used, and that the objectives provide the required working distance and contrast. Consider a sealed housing and anti-fungal optics for humid environments.
How does it compare with other Inverted Microscopes variants?
Choose an inverted microscope whenever the specimen must stay in its vessel, especially living cells. Decide the observation method first: brightfield for stained or dense samples, phase contrast for unstained living cells, and fluorescence for labelled molecules. Confirm the working distance suits the vessel base and whether an environmental chamber or heated stage is required. For multi-well plates and automated imaging, a motorised stage reduces handling. For wafer or component inspection, an inverted metallurgical version with reflected illumination is used. Match objectives, condenser and camera to the required resolution.
Full specifications
| Optical system | Infinite corrected |
|---|---|
| Magnification range | 40×–400× |
| Objectives | 4×, 10×, 20×, 40× long working distance |
| Eyepiece | 10× widefield |
| Working distance | Up to 8 mm |
| Stage | Fixed plate holder with inserts |
| Illumination | Cool LED, low heat output |
| Housing | Sealed, resistant to disinfection |
| Condenser | Long working distance phase option |
| Power supply | 100–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cell culture monitoring in incubators
- Sterile workflow observation
- Multi-well plate screening
- Stem-cell and primary culture work
Key features
- Compact stand fitting incubators and cabinets
- Sealed optics resistant to humidity and disinfectants
- Stage for flasks, dishes and multi-well plates
- Long working distance objectives, anti-fungal option
- Cool LED illumination for phase contrast
Frequently asked questions about Inverted Tissue Culture Microscope
Some compact inverted tissue culture microscopes are designed to fit incubators or cabinets, with sealed optics and low heat output so they do not disturb the environment. Always check the manufacturer's rating for temperature, humidity and disinfection before placing any instrument in such conditions.
Warm illumination heats the specimen and the surrounding air, which can affect cell growth and cause condensation on the vessel. Cool light-emitting diode illumination reduces heat, protects cultures and keeps the optics clear during long observation sessions.
By keeping samples in their sealed vessels, using a design that can be disinfected, and observing inside the sterile cabinet where possible. Sealed optics and smooth, cleanable surfaces prevent moisture and contaminants from entering the instrument and reduce cleaning effort.
With the objective below, the specimen stays in its culture vessel and the space above the stage is free for medium, tools and perfusion. This allows living cells to be observed without transferring them to a slide, and gives room for micromanipulation and environmental control.
Yes. Episcopic illumination passes through the objective from below, so fluorescence filter cubes work as in an upright microscope. This allows live cells in dishes to be imaged for labelled molecules while remaining in culture conditions.
The objective must focus through the plate base, typically about 1 mm thick, without touching it. Working distances of several millimetres are common for inverted objectives, and the best value depends on the vessel, the required numerical aperture and whether tools must also access the sample.
Related models