ICP Torch Box and RF Load Coil Assemblies

ICP 炬管箱和射频负载线圈组件

  • SKU IAC-0005
  • ICP Accessories
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • Electrical safety conformance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Coil materialcopper, silver plated
Coil turns2–4
Coolingwater or air
Generator frequency27 or 40 MHz typical
Power rating1000–1600 W
Interlocksdoor and torch sensors
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, USP <1058> Analytical Instrument Qualification, ISO 11885 Water quality — ICP-OES determination of elements

What is the ICP Torch Box and RF Load Coil Assemblies?

Torch boxes and radio-frequency load coil assemblies deliver plasma power and position the torch. They are replacement service parts that must match the generator and torch to sustain a stable, efficient plasma.

What is the ICP Torch Box and RF Load Coil Assemblies?

Torch boxes and radio-frequency load coil assemblies deliver plasma power and position the torch. They are replacement service parts that must match the generator and torch to sustain a stable, efficient plasma.

Overview

The load coil is a water- or air-cooled copper coil that surrounds the top of the torch and couples radio-frequency energy into the argon gas to form and sustain the plasma. Its geometry, number of turns, diameter and cooling determine coupling efficiency and the shape of the plasma. The torch box holds the torch, coil, gas connections and safety interlocks, and in many instruments it also contains the observation window or interface to the spectrometer. Coils can corrode or deform with heat and acid exposure, changing coupling and causing unstable plasma or ignition failure. Torch boxes may include light shields, interlocks that prevent operation with the door open, and positioning mechanisms for alignment. Replacement parts must match the generator frequency and power rating exactly.

How does it work?

The plasma and sample path are exposed to high temperature, acid fumes and salt deposits, so their components are consumables that wear, corrode or become contaminated. Quartz torches and injectors shape the plasma and must be replaced when they devitrify, crack or accumulate deposits that change sensitivity. Nebulizers and spray chambers set aerosol quality and transport efficiency. RF load coils and torch boxes deliver the plasma power and must be matched to the generator and torch. Peristaltic pump tubing controls sample flow and internal standard addition, and worn tubing changes volumes. Autosampler probes, trays and rinse stations determine carry-over and throughput. Using the correct part number and material for each instrument, element and matrix, and replacing parts on schedule, protects sensitivity, precision and safety.

What are the key features?

  • Water- or air-cooled copper load coil
  • Coil geometry matched to generator frequency
  • Torch box with gas connections and interlocks
  • Observation window or spectrometer interface
  • Alignment mechanism for plasma positioning
  • Replacement parts matching power and frequency

What are the technical specifications?

A typical icp torch box and rf load coil assemblies configuration offers coil material of copper, silver plated, coil turns of 2–4, cooling of water or air, generator frequency of 27 or 40 MHz typical, power rating of 1000–1600 W and interlocks of door and torch sensors. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The ICP Torch Box and RF Load Coil Assemblies is used in restoring plasma coupling after coil wear, replacement torch boxes for service, generator and coil matching for upgrades and maintenance of cooling and interlock systems. Across the wider ICP Accessories class, laboratories also deploy it for replacement torches and injectors for plasma systems, nebulizer and spray chamber maintenance kits and RF coil and torch box service parts.

Which standards and certifications apply?

Relevant standards and methods include USP <730> Plasma Spectrochemistry, USP <1058> Analytical Instrument Qualification, ISO 11885 Water quality — ICP-OES determination of elements, ISO 17294-2 Water quality — ICP-MS determination of elements, IEC 61010-1 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and Electrical safety conformance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Accessory condition is the most common reason for drifting sensitivity, noisy baselines and failed quality checks. Establish a maintenance schedule based on sample load and matrix: inspect torches and injectors for deposits and cracks, clean or replace nebulizers when uptake falls, and replace pump tubing and probes at defined intervals. Keep spares of the parts most likely to fail, because a blocked nebulizer or cracked torch stops the laboratory. Handle quartz carefully, store it clean and dry, and never use abrasive tools on injectors or nebulizers. After any replacement, verify performance with a check standard, confirm plasma stability and update the instrument log with the part and date.

How do I select the right ICP Torch Box and RF Load Coil Assemblies?

Select load coils and torch boxes by exact instrument model, generator frequency and power rating, and never substitute a part with different geometry or cooling. Tell the supplier the plasma instability or ignition symptoms, since coil condition is a common cause. Confirm that interlocks and cooling connections are included and tested after replacement.

How does it compare with other ICP Accessories variants?

Select accessories by exact instrument model, torch type and application. Quartz torches are standard for aqueous and many organic methods, while ceramic or inert torches suit hydrofluoric acid and high-purity work. Injector bore diameter affects aerosol velocity and plasma stability, so match it to the sample introduction system and matrix. Nebulizers range from concentric for clean solutions to V-groove or parallel-path for high solids. Spray chambers differ in transport efficiency and washout time. RF coils and torch boxes must match the generator frequency and power. Pump tubing is chosen by internal diameter and chemical resistance. Autosampler probes and trays must fit the sampler. Confirm part numbers, materials and availability of performance data before ordering.

Full specifications

Full specifications
Coil materialcopper, silver plated
Coil turns2–4
Coolingwater or air
Generator frequency27 or 40 MHz typical
Power rating1000–1600 W
Interlocksdoor and torch sensors
Coil diametermodel specific
Cooling water flow1–4 L/min
Compatible instrumentsmodel specific
Service intervalannual inspection

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Restoring plasma coupling after coil wear
  • Replacement torch boxes for service
  • Generator and coil matching for upgrades
  • Maintenance of cooling and interlock systems

Key features

  • Water- or air-cooled copper load coil
  • Coil geometry matched to generator frequency
  • Torch box with gas connections and interlocks
  • Observation window or spectrometer interface
  • Alignment mechanism for plasma positioning
  • Replacement parts matching power and frequency

Frequently asked questions about ICP Torch Box and RF Load Coil Assemblies

Symptoms include difficult ignition, unstable plasma, audible arcing, visible corrosion or deformation, and poor sensitivity that cannot be explained by other parts. A discolored or pitted coil is usually degraded. Inspect the coil during scheduled maintenance and replace it if there is any doubt.

Related models

All ICP Accessories

Request a quotation for the ICP Torch Box and RF Load Coil Assemblies

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote