Quartz Torches and Injectors for ICP
ICP 石英炬管和中心管
- SKU IAC-0001
- ICP Accessories
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Dimensional conformance to instrument specification (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Material | high-purity quartz |
|---|---|
| Injector bore | 1.0–2.5 mm |
| Configuration | demountable or one-piece |
| Plasma gas inlet | tangential |
| Auxiliary gas inlet | intermediate tube |
| Maximum temperature | up to 10000 K at plasma |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, USP <1058> Analytical Instrument Qualification, ISO 11885 Water quality — ICP-OES determination of elements
What is the Quartz Torches and Injectors for ICP?
Quartz torches and injectors shape and sustain the plasma and guide the aerosol into it. They are the most frequently replaced parts of an ICP system and directly affect sensitivity, ignition and stability.
What is the Quartz Torches and Injectors for ICP?
Quartz torches and injectors shape and sustain the plasma and guide the aerosol into it. They are the most frequently replaced parts of an ICP system and directly affect sensitivity, ignition and stability.
Overview
The torch is a concentric quartz assembly with an outer tube for plasma gas, an intermediate tube for auxiliary gas and a central injector through which the aerosol enters. The radio-frequency coil surrounds the torch top, and the plasma forms at its tip. Injector bore diameter, from about 1.0 to 2.5 millimetres, sets aerosol velocity and residence time in the plasma. Demountable torches allow the injector to be replaced separately, while one-piece torches are simpler but must be replaced as a unit. Torch bodies may have a ball joint or a socket to match the instrument. Quartz devitrifies with continued heating and devitrified or cracked torches cause poor ignition and unstable plasma, so inspection at each maintenance interval is essential.
How does it work?
The plasma and sample path are exposed to high temperature, acid fumes and salt deposits, so their components are consumables that wear, corrode or become contaminated. Quartz torches and injectors shape the plasma and must be replaced when they devitrify, crack or accumulate deposits that change sensitivity. Nebulizers and spray chambers set aerosol quality and transport efficiency. RF load coils and torch boxes deliver the plasma power and must be matched to the generator and torch. Peristaltic pump tubing controls sample flow and internal standard addition, and worn tubing changes volumes. Autosampler probes, trays and rinse stations determine carry-over and throughput. Using the correct part number and material for each instrument, element and matrix, and replacing parts on schedule, protects sensitivity, precision and safety.
What are the key features?
- Concentric outer, intermediate and injector tubes
- Demountable or one-piece configurations
- Injector bores from 1.0 to 2.5 mm
- Quartz, ceramic or inert material choices
- Ball joint or socket mounting options
- Direct effect on ignition and plasma stability
What are the technical specifications?
A typical quartz torches and injectors for icp configuration offers material of high-purity quartz, injector bore of 1.0–2.5 mm, configuration of demountable or one-piece, plasma gas inlet of tangential, auxiliary gas inlet of intermediate tube and maximum temperature of up to 10000 K at plasma. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Quartz Torches and Injectors for ICP is used in routine replacement for ICP-OES and ICP-MS, high-solids samples needing wider injectors, organic solvent methods with special torches and interchangeable injectors for different applications. Across the wider ICP Accessories class, laboratories also deploy it for replacement torches and injectors for plasma systems, nebulizer and spray chamber maintenance kits and RF coil and torch box service parts.
Which standards and certifications apply?
Relevant standards and methods include USP <730> Plasma Spectrochemistry, USP <1058> Analytical Instrument Qualification, ISO 11885 Water quality — ICP-OES determination of elements, ISO 17294-2 Water quality — ICP-MS determination of elements, IEC 61010-1 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and Dimensional conformance to instrument specification; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Accessory condition is the most common reason for drifting sensitivity, noisy baselines and failed quality checks. Establish a maintenance schedule based on sample load and matrix: inspect torches and injectors for deposits and cracks, clean or replace nebulizers when uptake falls, and replace pump tubing and probes at defined intervals. Keep spares of the parts most likely to fail, because a blocked nebulizer or cracked torch stops the laboratory. Handle quartz carefully, store it clean and dry, and never use abrasive tools on injectors or nebulizers. After any replacement, verify performance with a check standard, confirm plasma stability and update the instrument log with the part and date.
How do I select the right Quartz Torches and Injectors for ICP?
Select a torch and injector by instrument model and application, and choose a demountable design if you often change injector bores or materials. Use wider bores for high dissolved solids and narrower bores for organic solvents and improved sensitivity. Confirm material compatibility with hydrofluoric acid and keep a spare assembly ready.
How does it compare with other ICP Accessories variants?
Select accessories by exact instrument model, torch type and application. Quartz torches are standard for aqueous and many organic methods, while ceramic or inert torches suit hydrofluoric acid and high-purity work. Injector bore diameter affects aerosol velocity and plasma stability, so match it to the sample introduction system and matrix. Nebulizers range from concentric for clean solutions to V-groove or parallel-path for high solids. Spray chambers differ in transport efficiency and washout time. RF coils and torch boxes must match the generator frequency and power. Pump tubing is chosen by internal diameter and chemical resistance. Autosampler probes and trays must fit the sampler. Confirm part numbers, materials and availability of performance data before ordering.
Full specifications
| Material | high-purity quartz |
|---|---|
| Injector bore | 1.0–2.5 mm |
| Configuration | demountable or one-piece |
| Plasma gas inlet | tangential |
| Auxiliary gas inlet | intermediate tube |
| Maximum temperature | up to 10000 K at plasma |
| Mounting | ball joint or socket |
| Compatible instruments | model specific |
| Cleaning | dilute acid soak |
| Expected life | matrix dependent |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine replacement for ICP-OES and ICP-MS
- High-solids samples needing wider injectors
- Organic solvent methods with special torches
- Interchangeable injectors for different applications
Key features
- Concentric outer, intermediate and injector tubes
- Demountable or one-piece configurations
- Injector bores from 1.0 to 2.5 mm
- Quartz, ceramic or inert material choices
- Ball joint or socket mounting options
- Direct effect on ignition and plasma stability
Frequently asked questions about Quartz Torches and Injectors for ICP
Wider bores, around 2.0 to 2.5 millimetres, tolerate high dissolved solids and reduce blockage but allow larger droplets into the plasma. Narrower bores, around 1.0 to 1.5 millimetres, increase aerosol velocity for better sensitivity with clean samples and organic solvents. The choice is validated with the method.
Soak the torch in dilute nitric or hydrochloric acid, then rinse thoroughly with ultrapure water and dry. Do not use abrasives or strong bases, which scratch or etch quartz. Remove stubborn deposits with a mild acid and check for cracks or devitrification before reuse, discarding any damaged torch.
High dissolved solids, high plasma power, long daily operation and inadequate cleaning accelerate devitrification and deposits. Organic solvents without enough oxygen can deposit carbon. Matching the torch and injector to the matrix, cleaning on schedule and replacing before failure extend useful life and prevent plasma instability.
Replace the torch when it shows devitrification, cracks, a distorted tip, partial melting or deposits that cleaning cannot remove. Symptoms include unstable plasma, poor ignition, rising background and falling sensitivity. Torch life depends on sample matrix, power and cleaning practice, so inspect it at each maintenance interval.
High dissolved solids, high sample uptake and incomplete nebulization leave salt deposits on the injector tip and inside the bore. Deposits change aerosol velocity and can cause signal drift or plasma instability. Diluting samples, using a high-solids nebulizer and cleaning the injector in dilute acid reduce the problem.
Not usually, because torch dimensions, coil geometry, injector adapters and sampler fittings are instrument specific. Some third parties supply compatible parts for common models, but dimensional differences can cause poor plasma performance or damage. Confirm the exact model and part number, and prefer parts verified for your instrument.