Peristaltic Pump Tubing and Sample Loops for ICP
ICP 蠕动泵管和样品环
- SKU IAC-0004
- ICP Accessories
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Material cleanliness certification (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Tubing internal diameters | 0.25–2.8 mm |
|---|---|
| Materials | PVC, silicone, Tygon |
| Flow rates | 0.1–2 mL/min per channel |
| Channels | 3–5 |
| Sample loop volumes | 100–1000 µL |
| Chemical resistance | acid or solvent grades |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, USP <1058> Analytical Instrument Qualification, ISO 11885 Water quality — ICP-OES determination of elements
What is the Peristaltic Pump Tubing and Sample Loops for ICP?
Peristaltic pump tubing and sample loops control the flow of sample, internal standard and rinse solutions in ICP systems. They are low-cost consumables whose condition determines flow stability, dilution accuracy and precision.
What is the Peristaltic Pump Tubing and Sample Loops for ICP?
Peristaltic pump tubing and sample loops control the flow of sample, internal standard and rinse solutions in ICP systems. They are low-cost consumables whose condition determines flow stability, dilution accuracy and precision.
Overview
A peristaltic pump rotates rollers over flexible tubing, pushing liquid at a rate set by the tube internal diameter and rotation speed. Separate tubes carry sample, internal standard, rinse and, in some systems, diluent or hydride reagents. Because the tubing is squeezed repeatedly, it slowly deforms, hardens and changes delivered volume, so performance drifts unless tubing is replaced on schedule. Materials include PVC for aqueous solutions, silicone for flexibility and chemical resistance, and Tygon or similar blends for broader compatibility with organics. Sample loops in flow injection or valve systems meter precise volumes and must match the method volume. Keeping a supply of each tubing size and replacing all tubes together after maintenance preserves flow balance between channels.
How does it work?
The plasma and sample path are exposed to high temperature, acid fumes and salt deposits, so their components are consumables that wear, corrode or become contaminated. Quartz torches and injectors shape the plasma and must be replaced when they devitrify, crack or accumulate deposits that change sensitivity. Nebulizers and spray chambers set aerosol quality and transport efficiency. RF load coils and torch boxes deliver the plasma power and must be matched to the generator and torch. Peristaltic pump tubing controls sample flow and internal standard addition, and worn tubing changes volumes. Autosampler probes, trays and rinse stations determine carry-over and throughput. Using the correct part number and material for each instrument, element and matrix, and replacing parts on schedule, protects sensitivity, precision and safety.
What are the key features?
- Multiple channels for sample, standard and rinse
- Internal diameter sets the delivery rate
- PVC, silicone and Tygon material options
- Color-coded tubing for quick identification
- Sample loops for precise injection volumes
- Replacement on a defined schedule for stable flow
What are the technical specifications?
A typical peristaltic pump tubing and sample loops for icp configuration offers tubing internal diameters of 0.25–2.8 mm, materials of PVC, silicone, Tygon, flow rates of 0.1–2 mL/min per channel, channels of 3–5, sample loop volumes of 100–1000 µL and chemical resistance of acid or solvent grades. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Peristaltic Pump Tubing and Sample Loops for ICP is used in routine flow control in ICP-OES and ICP-MS, internal standard addition channels, on-line dilution and hydride reagent delivery and flow injection and valve system sample loops. Across the wider ICP Accessories class, laboratories also deploy it for replacement torches and injectors for plasma systems, nebulizer and spray chamber maintenance kits and RF coil and torch box service parts.
Which standards and certifications apply?
Relevant standards and methods include USP <730> Plasma Spectrochemistry, USP <1058> Analytical Instrument Qualification, ISO 11885 Water quality — ICP-OES determination of elements, ISO 17294-2 Water quality — ICP-MS determination of elements, IEC 61010-1 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and Material cleanliness certification; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Accessory condition is the most common reason for drifting sensitivity, noisy baselines and failed quality checks. Establish a maintenance schedule based on sample load and matrix: inspect torches and injectors for deposits and cracks, clean or replace nebulizers when uptake falls, and replace pump tubing and probes at defined intervals. Keep spares of the parts most likely to fail, because a blocked nebulizer or cracked torch stops the laboratory. Handle quartz carefully, store it clean and dry, and never use abrasive tools on injectors or nebulizers. After any replacement, verify performance with a check standard, confirm plasma stability and update the instrument log with the part and date.
How do I select the right Peristaltic Pump Tubing and Sample Loops for ICP?
Select tubing by the flow rate and chemical resistance your method requires, and match the internal diameter to the instrument channel. Keep several of each size in stock and replace all tubes together during maintenance to preserve flow balance. Track replacement dates and check uptake after every change.
How does it compare with other ICP Accessories variants?
Select accessories by exact instrument model, torch type and application. Quartz torches are standard for aqueous and many organic methods, while ceramic or inert torches suit hydrofluoric acid and high-purity work. Injector bore diameter affects aerosol velocity and plasma stability, so match it to the sample introduction system and matrix. Nebulizers range from concentric for clean solutions to V-groove or parallel-path for high solids. Spray chambers differ in transport efficiency and washout time. RF coils and torch boxes must match the generator frequency and power. Pump tubing is chosen by internal diameter and chemical resistance. Autosampler probes and trays must fit the sampler. Confirm part numbers, materials and availability of performance data before ordering.
Full specifications
| Tubing internal diameters | 0.25–2.8 mm |
|---|---|
| Materials | PVC, silicone, Tygon |
| Flow rates | 0.1–2 mL/min per channel |
| Channels | 3–5 |
| Sample loop volumes | 100–1000 µL |
| Chemical resistance | acid or solvent grades |
| Standard pack size | 12 pieces |
| Replacement interval | 2–12 weeks typical |
| Compatible instruments | model specific |
| Colour coding | by internal diameter |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine flow control in ICP-OES and ICP-MS
- Internal standard addition channels
- On-line dilution and hydride reagent delivery
- Flow injection and valve system sample loops
Key features
- Multiple channels for sample, standard and rinse
- Internal diameter sets the delivery rate
- PVC, silicone and Tygon material options
- Color-coded tubing for quick identification
- Sample loops for precise injection volumes
- Replacement on a defined schedule for stable flow
Frequently asked questions about Peristaltic Pump Tubing and Sample Loops for ICP
Replacement intervals depend on pump speed, running hours and tubing material, typically every two to twelve weeks of regular use. Replace sooner if uptake checks drift, if sensitivity changes without other cause, or if the tubing looks flattened or discolored. Always replace all channels together.
Internal standard and sample channels must deliver consistent relative volumes, because the internal standard correction assumes a fixed ratio. If one tube wears faster, the ratio changes and the correction becomes inaccurate. Replacing all channels together and verifying uptake keeps the ratio stable.
Solvent-resistant grades such as Tygon or specific fluoropolymer-lined tubing are used for organic solvents, because PVC and standard silicone swell or harden. Confirm compatibility with the exact solvent and check for swelling. Inert PFA tubing carries hydrofluoric acid and ultrapure solutions.
Replace the torch when it shows devitrification, cracks, a distorted tip, partial melting or deposits that cleaning cannot remove. Symptoms include unstable plasma, poor ignition, rising background and falling sensitivity. Torch life depends on sample matrix, power and cleaning practice, so inspect it at each maintenance interval.
High dissolved solids, high sample uptake and incomplete nebulization leave salt deposits on the injector tip and inside the bore. Deposits change aerosol velocity and can cause signal drift or plasma instability. Diluting samples, using a high-solids nebulizer and cleaning the injector in dilute acid reduce the problem.
Not usually, because torch dimensions, coil geometry, injector adapters and sampler fittings are instrument specific. Some third parties supply compatible parts for common models, but dimensional differences can cause poor plasma performance or damage. Confirm the exact model and part number, and prefer parts verified for your instrument.
Related models