HPLC System for Related Substances Testing
有关物质检测 HPLC 系统
- SKU HPC-0003
- HPLC
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Pressure limit | 600–1000 bar |
|---|---|
| Gradient | Quaternary low-pressure or binary high-pressure |
| Dwell volume | about 0.5–1.5 mL |
| Detection | Diode-array, optional mass spectrometry |
| Detection limit | about 0.01 percent of main peak |
| Wavelength range | 190–800 nm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <621>, USP <711>, USP <905>
What is the HPLC System for Related Substances Testing?
An HPLC system for related substances testing separates and quantifies impurities and degradation products at low levels. It is chosen when a product must meet pharmacopoeial impurity limits and report full impurity profiles.
What is the HPLC System for Related Substances Testing?
An HPLC system for related substances testing separates and quantifies impurities and degradation products at low levels. It is chosen when a product must meet pharmacopoeial impurity limits and report full impurity profiles.
Overview
Related substances methods must resolve the active ingredient from process impurities, degradation products and other related compounds, often at levels below 0.1 percent of the main peak. This demands gradient elution to separate compounds of differing polarity, low dwell volume to keep gradient profiles reproducible, and sensitive detection, commonly diode-array for peak purity checks or mass spectrometry for identification. Column choice and mobile phase pH are critical because small changes alter selectivity, and system suitability criteria include resolution between specified peaks and relative retention times. Impurity reference standards or relative response factors are used to quantify unknowns, and reporting, identification and qualification thresholds from ICH Q3A and Q3B guide the method. The method is usually stability indicating and is run across stability studies.
How does it work?
HPLC pumps a liquid mobile phase through a column packed with stationary phase. The sample is injected, and components partition between the mobile and stationary phases, so they elute at characteristic retention times. A detector, usually UV-Vis or diode-array, records absorbance and gives peak areas proportional to concentration. Pharmaceutical methods use reversed-phase columns in most cases, with buffered aqueous and organic mobile phases, isocratic or gradient elution, and a column oven for reproducibility. System suitability parameters such as resolution, tailing factor, theoretical plates and relative standard deviation must meet the criteria in the monograph before results are reported. Pump accuracy, injector precision, detector linearity, column temperature and mobile phase preparation all influence performance, so qualification and method control are essential.
What are the key features?
- Gradient elution for compounds of differing polarity
- Low dwell volume for reproducible gradients
- Diode-array detector for peak purity checks
- Mass spectrometry option for identification
- Resolution and relative retention suitability criteria
- Quantification against impurity standards or response factors
What are the technical specifications?
A typical hplc system for related substances testing configuration offers pressure limit of 600–1000 bar, gradient of Quaternary low-pressure or binary high-pressure, dwell volume of about 0.5–1.5 mL, detection of Diode-array, optional mass spectrometry, detection limit of about 0.01 percent of main peak and wavelength range of 190–800 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The HPLC System for Related Substances Testing is used in impurity and degradation product testing, stability indicating methods, forced degradation studies and genotoxic impurity support. Across the wider HPLC class, laboratories also deploy it for pharmacopoeial assay of drug substances, related substances and impurity testing and dissolution sample analysis.
Which standards and certifications apply?
Relevant standards and methods include USP <621>, USP <711>, USP <905>, ICH Q2(R2), ICH Q3A and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the system on a stable bench with a solvent tray and waste container below it, and keep the laboratory free of vibration and temperature swings that affect retention. Use HPLC-grade solvents and filtered, degassed mobile phases, and prepare buffers fresh because microbial growth damages columns. Equilibrate the column at the method flow and temperature before each run, and verify system suitability before samples. Change seals, pistons and lamps on schedule, and record maintenance. Retain raw chromatograms, integration parameters and audit trails, because regulators expect the original data. Dispose of solvent waste as hazardous waste according to local rules.
How do I select the right HPLC System for Related Substances Testing?
Specify a related substances system when impurity limits and profiles must be met. Confirm gradient capability, dwell volume, detector sensitivity and peak purity functionality, plus column oven control. Consider a mass spectrometer for identification of unknowns, and validate the method with spiked samples and forced degradation.
How does it compare with other HPLC variants?
Select an HPLC system from the method itself. For pharmacopoeial assay, a robust isocratic or simple gradient system with UV detection is usually enough. For related substances and degradation products, gradient capability, low dwell volume and a diode-array or mass spectrometer detector help separate and identify impurities at low levels. For dissolution samples, a system with a high-capacity autosampler and fast run times is more valuable than high resolution. UHPLC suits laboratories that want shorter run times and better resolution, provided the method is transferred and validated. Compare pressure limit, flow range, autosampler capacity and precision, detector options, column oven control and software for data integrity. Confirm qualification documents and service support.
Full specifications
| Pressure limit | 600–1000 bar |
|---|---|
| Gradient | Quaternary low-pressure or binary high-pressure |
| Dwell volume | about 0.5–1.5 mL |
| Detection | Diode-array, optional mass spectrometry |
| Detection limit | about 0.01 percent of main peak |
| Wavelength range | 190–800 nm |
| Column oven | ambient to 80 °C, ±0.5 °C |
| Power supply | 220 V, 50 Hz, about 1.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Impurity and degradation product testing
- Stability indicating methods
- Forced degradation studies
- Genotoxic impurity support
Key features
- Gradient elution for compounds of differing polarity
- Low dwell volume for reproducible gradients
- Diode-array detector for peak purity checks
- Mass spectrometry option for identification
- Resolution and relative retention suitability criteria
- Quantification against impurity standards or response factors
Frequently asked questions about HPLC System for Related Substances Testing
Because impurities and degradation products can differ widely in polarity from the active ingredient. Gradient elution changes mobile phase strength during the run so early polar and late non-polar compounds are both retained and resolved within a practical run time.
ICH Q3A and Q3B define thresholds above which an impurity must be reported, identified or qualified as safe. Impurities above the identification threshold need structural characterisation, and those above the qualification threshold need toxicological assessment.
By comparing ultraviolet spectra across the peak with a diode-array detector. A pure peak has consistent spectra, while spectral differences indicate a co-eluting impurity. Mass spectrometry gives stronger evidence when overlapping peaks are suspected.
It is a set of checks that confirm the instrument, column and method perform as expected at the time of analysis. Resolution, tailing factor, theoretical plates and precision must meet monograph criteria before sample results are considered valid.
It records the full ultraviolet spectrum at each point in the run, so peaks can be checked for purity and compared with reference spectra. This helps distinguish a true impurity from a co-eluting peak and supports peak identification.
When shorter run times, better resolution or higher throughput are needed, or when the laboratory already has validated UHPLC methods. The method must be transferred with attention to extra-column volume and frictional heating, and the expected benefit should justify the change.