HPLC System for Dissolution Sample Analysis
溶出样品分析 HPLC 系统
- SKU HPC-0002
- HPLC
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Autosampler capacity | about 120–300 vials |
|---|---|
| Run time per sample | about 2–10 min |
| Pressure limit | 600–1000 bar for UHPLC |
| Detection | UV or diode-array |
| Flow rate range | 0.1–10 mL/min |
| Column oven | ambient to 80 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <621>, USP <711>, USP <905>
What is the HPLC System for Dissolution Sample Analysis?
An HPLC system for dissolution sample analysis handles large numbers of filtered aliquots from dissolution vessels at short intervals. It is chosen when UV-Vis alone cannot resolve the drug from excipients or when multiple analytes are measured.
What is the HPLC System for Dissolution Sample Analysis?
An HPLC system for dissolution sample analysis handles large numbers of filtered aliquots from dissolution vessels at short intervals. It is chosen when UV-Vis alone cannot resolve the drug from excipients or when multiple analytes are measured.
Overview
Dissolution testing generates many samples: six or more vessels multiplied by several time points. HPLC is used when the drug cannot be measured directly by UV-Vis, for example when excipients absorb, when the drug has multiple components, or when a stability-indicating method is required. The system needs a high-capacity autosampler, short run times and often a fast or UHPLC column so that all samples from a run can be analysed within a reasonable time. Automated sample collection from the dissolution apparatus can be linked to the autosampler, and methods typically use isocratic elution with UV or diode-array detection. Because concentrations change during the run, the calibration range must cover low early points and high later points, and the method should be validated over that range.
How does it work?
HPLC pumps a liquid mobile phase through a column packed with stationary phase. The sample is injected, and components partition between the mobile and stationary phases, so they elute at characteristic retention times. A detector, usually UV-Vis or diode-array, records absorbance and gives peak areas proportional to concentration. Pharmaceutical methods use reversed-phase columns in most cases, with buffered aqueous and organic mobile phases, isocratic or gradient elution, and a column oven for reproducibility. System suitability parameters such as resolution, tailing factor, theoretical plates and relative standard deviation must meet the criteria in the monograph before results are reported. Pump accuracy, injector precision, detector linearity, column temperature and mobile phase preparation all influence performance, so qualification and method control are essential.
What are the key features?
- High-capacity autosampler for many vials
- Short run times with fast or UHPLC columns
- Isocratic method with UV or diode-array detection
- Link to automated dissolution sampling
- Calibration range covering early to late points
- Batch reporting for vessel and time point
What are the technical specifications?
A typical hplc system for dissolution sample analysis configuration offers autosampler capacity of about 120–300 vials, run time per sample of about 2–10 min, pressure limit of 600–1000 bar for UHPLC, detection of UV or diode-array, flow rate range of 0.1–10 mL/min and column oven of ambient to 80 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The HPLC System for Dissolution Sample Analysis is used in dissolution profile analysis, modified-release release testing, multi-component dissolution methods and excipient interference cases. Across the wider HPLC class, laboratories also deploy it for pharmacopoeial assay of drug substances, related substances and impurity testing and dissolution sample analysis.
Which standards and certifications apply?
Relevant standards and methods include USP <621>, USP <711>, USP <905>, ICH Q2(R2), ICH Q3A and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the system on a stable bench with a solvent tray and waste container below it, and keep the laboratory free of vibration and temperature swings that affect retention. Use HPLC-grade solvents and filtered, degassed mobile phases, and prepare buffers fresh because microbial growth damages columns. Equilibrate the column at the method flow and temperature before each run, and verify system suitability before samples. Change seals, pistons and lamps on schedule, and record maintenance. Retain raw chromatograms, integration parameters and audit trails, because regulators expect the original data. Dispose of solvent waste as hazardous waste according to local rules.
How do I select the right HPLC System for Dissolution Sample Analysis?
Choose HPLC for dissolution when UV-Vis cannot separate the drug from excipients, when multiple analytes are measured, or when the method must be stability indicating. Confirm autosampler capacity, run time, calibration range and any link to the dissolution sampler. Plan a system that can finish a full vessel set within the required turnaround.
How does it compare with other HPLC variants?
Select an HPLC system from the method itself. For pharmacopoeial assay, a robust isocratic or simple gradient system with UV detection is usually enough. For related substances and degradation products, gradient capability, low dwell volume and a diode-array or mass spectrometer detector help separate and identify impurities at low levels. For dissolution samples, a system with a high-capacity autosampler and fast run times is more valuable than high resolution. UHPLC suits laboratories that want shorter run times and better resolution, provided the method is transferred and validated. Compare pressure limit, flow range, autosampler capacity and precision, detector options, column oven control and software for data integrity. Confirm qualification documents and service support.
Full specifications
| Autosampler capacity | about 120–300 vials |
|---|---|
| Run time per sample | about 2–10 min |
| Pressure limit | 600–1000 bar for UHPLC |
| Detection | UV or diode-array |
| Flow rate range | 0.1–10 mL/min |
| Column oven | ambient to 80 °C |
| Dissolution interface | Automated sampling link |
| Power supply | 220 V, 50 Hz, about 1.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Dissolution profile analysis
- Modified-release release testing
- Multi-component dissolution methods
- Excipient interference cases
Key features
- High-capacity autosampler for many vials
- Short run times with fast or UHPLC columns
- Isocratic method with UV or diode-array detection
- Link to automated dissolution sampling
- Calibration range covering early to late points
- Batch reporting for vessel and time point
Frequently asked questions about HPLC System for Dissolution Sample Analysis
When excipients or the medium absorb at the detection wavelength, when the formulation contains two or more actives, when degradation products must be distinguished from the parent drug, or when the method must be stability indicating.
Six or more vessels multiplied by the number of time points, so a single run can generate dozens of vials. Autosampler capacity and run time therefore determine whether analysis can keep pace with sample collection.
It must cover the lowest concentration expected at the first time point through to the highest near complete release, often spanning two orders of magnitude. Linearity, accuracy and precision are then validated across that range as required by ICH Q2.
It is a set of checks that confirm the instrument, column and method perform as expected at the time of analysis. Resolution, tailing factor, theoretical plates and precision must meet monograph criteria before sample results are considered valid.
It records the full ultraviolet spectrum at each point in the run, so peaks can be checked for purity and compared with reference spectra. This helps distinguish a true impurity from a co-eluting peak and supports peak identification.
When shorter run times, better resolution or higher throughput are needed, or when the laboratory already has validated UHPLC methods. The method must be transferred with attention to extra-column volume and frictional heating, and the expected benefit should justify the change.
Related models




HPLC System with Diode-Array Detection for Method Validation
配二极管阵列检测器的 HPLC 方法验证系统
- CE (to be confirmed)
- +2

Double-Beam UV-Vis Spectrophotometer for Pharmaceutical Quality Control
制药质量控制双光束紫外可见分光光度计
- CE (to be confirmed)
- +2