HPLC System for Pharmacopoeial Assay
药典含量测定 HPLC 系统
- SKU HPC-0001
- HPLC
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Pressure limit | 400–600 bar |
|---|---|
| Flow rate range | 0.1–10 mL/min |
| Flow accuracy | ±1 percent or better |
| Detection | UV or diode-array |
| Wavelength range | 190–800 nm |
| Autosampler capacity | up to about 100 vials |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <621>, USP <711>, USP <905>
What is the HPLC System for Pharmacopoeial Assay?
An HPLC system for pharmacopoeial assay quantifies the active ingredient against a reference standard using a validated isocratic or simple gradient method. It is the standard approach for content testing of drug substances and products.
What is the HPLC System for Pharmacopoeial Assay?
An HPLC system for pharmacopoeial assay quantifies the active ingredient against a reference standard using a validated isocratic or simple gradient method. It is the standard approach for content testing of drug substances and products.
Overview
Assay by HPLC is usually an isocratic reversed-phase method with UV detection at a single wavelength, comparing sample peak area with the response of a reference standard. Because assay demands accuracy and precision rather than extreme resolution, the system can be relatively simple: a reliable pump, a precise autosampler, a UV or diode-array detector and a well-controlled column oven. Method parameters such as flow rate, mobile phase composition, column temperature and detection wavelength are fixed by the monograph, and system suitability confirms that the chromatographic system is fit for purpose before samples are run. Duplicate injections of standard and sample, and periodic bracketing standards, correct for drift. Robustness and reproducibility across many batches matter more than speed.
How does it work?
HPLC pumps a liquid mobile phase through a column packed with stationary phase. The sample is injected, and components partition between the mobile and stationary phases, so they elute at characteristic retention times. A detector, usually UV-Vis or diode-array, records absorbance and gives peak areas proportional to concentration. Pharmaceutical methods use reversed-phase columns in most cases, with buffered aqueous and organic mobile phases, isocratic or gradient elution, and a column oven for reproducibility. System suitability parameters such as resolution, tailing factor, theoretical plates and relative standard deviation must meet the criteria in the monograph before results are reported. Pump accuracy, injector precision, detector linearity, column temperature and mobile phase preparation all influence performance, so qualification and method control are essential.
What are the key features?
- Isocratic or simple gradient pump
- UV or diode-array detection at fixed wavelength
- Precise autosampler with standard bracketing
- Column oven for retention reproducibility
- System suitability reporting built in
- Robust performance across many batches
What are the technical specifications?
A typical hplc system for pharmacopoeial assay configuration offers pressure limit of 400–600 bar, flow rate range of 0.1–10 mL/min, flow accuracy of ±1 percent or better, detection of UV or diode-array, wavelength range of 190–800 nm and autosampler capacity of up to about 100 vials. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The HPLC System for Pharmacopoeial Assay is used in drug substance and product assay, content uniformity testing, stability indicating assay and excipient content testing. Across the wider HPLC class, laboratories also deploy it for pharmacopoeial assay of drug substances, related substances and impurity testing and dissolution sample analysis.
Which standards and certifications apply?
Relevant standards and methods include USP <621>, USP <711>, USP <905>, ICH Q2(R2), ICH Q3A and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the system on a stable bench with a solvent tray and waste container below it, and keep the laboratory free of vibration and temperature swings that affect retention. Use HPLC-grade solvents and filtered, degassed mobile phases, and prepare buffers fresh because microbial growth damages columns. Equilibrate the column at the method flow and temperature before each run, and verify system suitability before samples. Change seals, pistons and lamps on schedule, and record maintenance. Retain raw chromatograms, integration parameters and audit trails, because regulators expect the original data. Dispose of solvent waste as hazardous waste according to local rules.
How do I select the right HPLC System for Pharmacopoeial Assay?
Choose an assay system when the method is isocratic or uses a simple gradient and detection at one wavelength. Confirm flow accuracy, autosampler precision, detector linearity and column oven stability. Include qualification, system suitability software and service support in the evaluation.
How does it compare with other HPLC variants?
Select an HPLC system from the method itself. For pharmacopoeial assay, a robust isocratic or simple gradient system with UV detection is usually enough. For related substances and degradation products, gradient capability, low dwell volume and a diode-array or mass spectrometer detector help separate and identify impurities at low levels. For dissolution samples, a system with a high-capacity autosampler and fast run times is more valuable than high resolution. UHPLC suits laboratories that want shorter run times and better resolution, provided the method is transferred and validated. Compare pressure limit, flow range, autosampler capacity and precision, detector options, column oven control and software for data integrity. Confirm qualification documents and service support.
Full specifications
| Pressure limit | 400–600 bar |
|---|---|
| Flow rate range | 0.1–10 mL/min |
| Flow accuracy | ±1 percent or better |
| Detection | UV or diode-array |
| Wavelength range | 190–800 nm |
| Autosampler capacity | up to about 100 vials |
| Column oven | ambient to 80 °C, ±0.5 °C |
| Power supply | 220 V, 50 Hz, about 1 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drug substance and product assay
- Content uniformity testing
- Stability indicating assay
- Excipient content testing
Key features
- Isocratic or simple gradient pump
- UV or diode-array detection at fixed wavelength
- Precise autosampler with standard bracketing
- Column oven for retention reproducibility
- System suitability reporting built in
- Robust performance across many batches
Frequently asked questions about HPLC System for Pharmacopoeial Assay
Because assay needs consistent retention and response rather than separation of many components, and an isocratic method is simpler, requires no gradient proportioning valves and equilibrates quickly. It is also easier to reproduce between laboratories.
A standard of known purity and potency is injected in duplicate and bracketed around the sample set. Sample results are calculated from the ratio of areas, corrected for concentration and any conversion factor specified in the monograph.
Do not report sample results. Investigate the cause, which may be a depleted column, incorrect mobile phase, air in the pump or a drifting detector, then correct it and repeat suitability. Records of failed attempts and the corrective action should be kept.
It is a set of checks that confirm the instrument, column and method perform as expected at the time of analysis. Resolution, tailing factor, theoretical plates and precision must meet monograph criteria before sample results are considered valid.
It records the full ultraviolet spectrum at each point in the run, so peaks can be checked for purity and compared with reference spectra. This helps distinguish a true impurity from a co-eluting peak and supports peak identification.
When shorter run times, better resolution or higher throughput are needed, or when the laboratory already has validated UHPLC methods. The method must be transferred with attention to extra-column volume and frictional heating, and the expected benefit should justify the change.
Related models




HPLC System with Diode-Array Detection for Method Validation
配二极管阵列检测器的 HPLC 方法验证系统
- CE (to be confirmed)
- +2