UV-Vis Spectrophotometer for Content Uniformity Testing
含量均匀度检测紫外可见分光光度计
- SKU UVI-0004
- UV-Vis
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 190–1100 nm |
|---|---|
| Wavelength accuracy | ±0.5 nm |
| Photometric accuracy | about ±0.005 AU at 1 AU |
| Sampling | Cell changer or sipper |
| Vials per rack | 10–30 |
| Measurement time | about 2–5 s per unit |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <851>, USP <857>, USP <711>
What is the UV-Vis Spectrophotometer for Content Uniformity Testing?
A UV-Vis spectrophotometer for content uniformity testing measures individual dosage units after extraction and dilution. It is chosen when a fast, low-cost per-unit measurement is adequate for single-component products and no separation is required.
What is the UV-Vis Spectrophotometer for Content Uniformity Testing?
A UV-Vis spectrophotometer for content uniformity testing measures individual dosage units after extraction and dilution. It is chosen when a fast, low-cost per-unit measurement is adequate for single-component products and no separation is required.
Overview
Content uniformity requires each dosage unit to be extracted and measured separately. UV-Vis suits this when the product contains a single active ingredient with a clear absorbance and excipients do not interfere. Each unit is weighed, comminuted and extracted to a defined volume, then diluted so the absorbance falls in the linear range, and measured against a calibration curve. Because many units are measured, a cell changer or sipper system that reads vials automatically improves speed and reproducibility, and software calculates per-unit results against the monograph acceptance values. The critical requirements are quantitative extraction, accurate dilution and consistent cell or sipper path length, since a small systematic error is repeated across every unit.
How does it work?
A UV-Vis spectrophotometer passes light from a deuterium lamp, for ultraviolet, and a tungsten or halogen lamp, for visible, through a monochromator and then through a sample. Transmitted intensity is compared with that through a reference to give absorbance, which follows the Beer-Lambert relationship when the absorbing species, path length and wavelength are fixed. Concentration is calculated from absorbance using a calibration curve or an absorptivity value. In pharmaceutical work the sample is usually a diluted solution or a filtered dissolution aliquot held in a quartz or matched glass cell. Absorbance range, wavelength accuracy, stray light, spectral bandwidth and cell path length determine the usable range, and the method defines the wavelength, blank and standard procedure.
What are the key features?
- Per-unit measurement after extraction
- Cell changer or sipper for automatic reading
- Software calculation against acceptance values
- Calibration curve in the linear range
- Single-component product suitability
- Consistent path length for all units
What are the technical specifications?
A typical uv-vis spectrophotometer for content uniformity testing configuration offers wavelength range of 190–1100 nm, wavelength accuracy of ±0.5 nm, photometric accuracy of about ±0.005 AU at 1 AU, sampling of Cell changer or sipper, vials per rack of 10–30 and measurement time of about 2–5 s per unit. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The UV-Vis Spectrophotometer for Content Uniformity Testing is used in content uniformity testing, potency testing of single-unit products, low-dose product testing and in-process uniformity checks. Across the wider UV-Vis class, laboratories also deploy it for pharmaceutical assay, content uniformity testing and dissolution monitoring.
Which standards and certifications apply?
Relevant standards and methods include USP <851>, USP <857>, USP <711>, USP <905>, ICH Q2(R2) and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the instrument on a stable bench away from direct sun and draughts, and allow the lamps to warm up and stabilise before measurement. Use matched cells of the specified path length and check them for scratches and contamination, because a mismatched cell introduces a constant error. Verify wavelength accuracy and photometric accuracy at defined intervals with certified reference materials, and record the results. Prepare solutions accurately and measure within the validated absorbance range, since high absorbance reduces linearity. Replace lamps when energy falls, and keep cells clean and stored properly. Retain raw spectra and calibration data for regulatory inspection.
How do I select the right UV-Vis Spectrophotometer for Content Uniformity Testing?
Choose UV-Vis for content uniformity when the product has one active ingredient and no interference. Confirm photometric accuracy and stability, changer or sipper capacity, and software that reports per-unit values against the acceptance criteria. Plan careful extraction and dilution validation.
How does it compare with other UV-Vis variants?
Choose the spectrophotometer from the method and the sample workload. Single-beam instruments suit routine assay at a fixed wavelength, where cost and simplicity matter. Double-beam optics compensate for lamp drift and are preferred for stability-indicating methods, wavelength scans and long runs. Diode-array instruments capture a full spectrum quickly, which helps method development and multi-wavelength work. For dissolution monitoring, dedicated fibre-optic systems measure absorbance directly in the vessel. Compare wavelength range and accuracy, photometric range and noise, cell changer capacity and warm-up stability. Confirm that the instrument can be qualified with standards such as potassium dichromate or holmium oxide filters, and that software supports audit trails.
Full specifications
| Wavelength range | 190–1100 nm |
|---|---|
| Wavelength accuracy | ±0.5 nm |
| Photometric accuracy | about ±0.005 AU at 1 AU |
| Sampling | Cell changer or sipper |
| Vials per rack | 10–30 |
| Measurement time | about 2–5 s per unit |
| Software | Per-unit calculation and reporting |
| Power supply | 220 V, 50 Hz, about 0.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Content uniformity testing
- Potency testing of single-unit products
- Low-dose product testing
- In-process uniformity checks
Key features
- Per-unit measurement after extraction
- Cell changer or sipper for automatic reading
- Software calculation against acceptance values
- Calibration curve in the linear range
- Single-component product suitability
- Consistent path length for all units
Frequently asked questions about UV-Vis Spectrophotometer for Content Uniformity Testing
When the product contains multiple actives, when excipients or the extraction solvent absorb at the chosen wavelength, when degradation products must be separated, or when the active concentration is too low for reliable UV-Vis measurement.
Because the same extraction is applied to every unit, any incomplete recovery shifts all results in the same direction and could cause a compliant batch to fail or vice versa. Recovery should be demonstrated for each product and strength.
Per-unit calculation against monograph acceptance values, automatic flagging of outliers, storage of calibration data and audit trails. Export to a laboratory information management system reduces transcription errors and speeds review.
Absorbance is proportional to the concentration of the absorbing species and the path length, at a fixed wavelength. This linear relationship allows concentration to be calculated from measured absorbance, provided the solution is dilute and no interfering species absorb.
Wavelength accuracy is checked with holmium oxide or didymium filters, photometric accuracy with potassium dichromate or neutral density filters, and noise and stray light are verified by the manufacturer's procedure. Checks are repeated at defined intervals and after service.
Absorbance depends on path length and the optical quality of the cell. Unmatched or scratched cells add a constant error to every reading, which can shift results even when the chemistry is correct, so cells should be paired and inspected regularly.
Related models



Double-Beam UV-Vis Spectrophotometer for Pharmaceutical Quality Control
制药质量控制双光束紫外可见分光光度计
- CE (to be confirmed)
- +2

Diode-Array UV-Vis Spectrophotometer for Pharmaceutical Analysis
药品分析二极管阵列紫外可见分光光度计
- CE (to be confirmed)
- +2


HPLC System with Diode-Array Detection for Method Validation
配二极管阵列检测器的 HPLC 方法验证系统
- CE (to be confirmed)
- +2