

UV-Vis Spectrophotometer for Pharmaceutical Assay
药品含量测定紫外可见分光光度计
- SKU UVI-0001
- UV-Vis
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 190–1100 nm |
|---|---|
| Wavelength accuracy | ±0.5 nm |
| Photometric range | –0.3 to 3.0 AU |
| Photometric accuracy | about ±0.005 AU at 1 AU |
| Spectral bandwidth | 2 nm typical |
| Optics | Single beam |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <851>, USP <857>, USP <711>
What is the UV-Vis Spectrophotometer for Pharmaceutical Assay?
A UV-Vis spectrophotometer for pharmaceutical assay measures absorbance at a fixed wavelength and calculates content from a calibration curve or absorptivity value. It is the simplest and fastest option for routine content testing of solutions.
What is the UV-Vis Spectrophotometer for Pharmaceutical Assay?
A UV-Vis spectrophotometer for pharmaceutical assay measures absorbance at a fixed wavelength and calculates content from a calibration curve or absorptivity value. It is the simplest and fastest option for routine content testing of solutions.
Overview
Assay by UV-Vis is a single-wavelength measurement against a blank, with concentration calculated from a calibration curve or the absorptivity specified in the monograph. The method is fast, inexpensive and uses little solvent, which makes it attractive for high-volume routine testing of drug substances, injectables and simple oral solutions. A single-beam instrument with a fixed wavelength and a matched cell is often adequate, provided the chemistry gives a stable and specific absorbance. Sample preparation must be quantitative and the dilution scheme appropriate so absorbance falls in the linear range. Because the technique is not separatory, it fails where excipients, degradation products or the medium absorb at the same wavelength, and then HPLC is required. Method validation covers linearity, accuracy, precision and specificity.
How does it work?
A UV-Vis spectrophotometer passes light from a deuterium lamp, for ultraviolet, and a tungsten or halogen lamp, for visible, through a monochromator and then through a sample. Transmitted intensity is compared with that through a reference to give absorbance, which follows the Beer-Lambert relationship when the absorbing species, path length and wavelength are fixed. Concentration is calculated from absorbance using a calibration curve or an absorptivity value. In pharmaceutical work the sample is usually a diluted solution or a filtered dissolution aliquot held in a quartz or matched glass cell. Absorbance range, wavelength accuracy, stray light, spectral bandwidth and cell path length determine the usable range, and the method defines the wavelength, blank and standard procedure.
What are the key features?
- Fixed-wavelength absorbance measurement
- Calibration curve or absorptivity calculation
- Single-beam optics for routine work
- Matched quartz cells of defined path length
- Low solvent consumption and fast turnaround
- Method validation for linearity and accuracy
What are the technical specifications?
A typical uv-vis spectrophotometer for pharmaceutical assay configuration offers wavelength range of 190–1100 nm, wavelength accuracy of ±0.5 nm, photometric range of –0.3 to 3.0 AU, photometric accuracy of about ±0.005 AU at 1 AU, spectral bandwidth of 2 nm typical and optics of Single beam. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The UV-Vis Spectrophotometer for Pharmaceutical Assay is used in drug substance assay, injectable solution assay, oral solution content testing and colorimetric limit tests. Across the wider UV-Vis class, laboratories also deploy it for pharmaceutical assay, content uniformity testing and dissolution monitoring.
Which standards and certifications apply?
Relevant standards and methods include USP <851>, USP <857>, USP <711>, USP <905>, ICH Q2(R2) and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the instrument on a stable bench away from direct sun and draughts, and allow the lamps to warm up and stabilise before measurement. Use matched cells of the specified path length and check them for scratches and contamination, because a mismatched cell introduces a constant error. Verify wavelength accuracy and photometric accuracy at defined intervals with certified reference materials, and record the results. Prepare solutions accurately and measure within the validated absorbance range, since high absorbance reduces linearity. Replace lamps when energy falls, and keep cells clean and stored properly. Retain raw spectra and calibration data for regulatory inspection.
How do I select the right UV-Vis Spectrophotometer for Pharmaceutical Assay?
Choose a single-beam instrument when the method specifies one wavelength and samples are simple solutions. Confirm wavelength range, photometric accuracy and stability, and cell compatibility with your solvents. If the laboratory also runs scans or long stability batches, a double-beam or diode-array model may be more suitable.
How does it compare with other UV-Vis variants?
Choose the spectrophotometer from the method and the sample workload. Single-beam instruments suit routine assay at a fixed wavelength, where cost and simplicity matter. Double-beam optics compensate for lamp drift and are preferred for stability-indicating methods, wavelength scans and long runs. Diode-array instruments capture a full spectrum quickly, which helps method development and multi-wavelength work. For dissolution monitoring, dedicated fibre-optic systems measure absorbance directly in the vessel. Compare wavelength range and accuracy, photometric range and noise, cell changer capacity and warm-up stability. Confirm that the instrument can be qualified with standards such as potassium dichromate or holmium oxide filters, and that software supports audit trails.
Full specifications
| Wavelength range | 190–1100 nm |
|---|---|
| Wavelength accuracy | ±0.5 nm |
| Photometric range | –0.3 to 3.0 AU |
| Photometric accuracy | about ±0.005 AU at 1 AU |
| Spectral bandwidth | 2 nm typical |
| Optics | Single beam |
| Cell path length | 10 mm standard |
| Power supply | 220 V, 50 Hz, about 0.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drug substance assay
- Injectable solution assay
- Oral solution content testing
- Colorimetric limit tests
Key features
- Fixed-wavelength absorbance measurement
- Calibration curve or absorptivity calculation
- Single-beam optics for routine work
- Matched quartz cells of defined path length
- Low solvent consumption and fast turnaround
- Method validation for linearity and accuracy
Frequently asked questions about UV-Vis Spectrophotometer for Pharmaceutical Assay
When the drug has a distinct absorbance, the matrix does not interfere at that wavelength, and the method does not need to separate related substances. If excipients, degradants or the medium absorb, or if impurities must be measured, HPLC is required.
A reference standard of known purity is dissolved and diluted to give at least five concentration levels spanning the working range. Absorbance is plotted against concentration, and linearity is assessed by regression and residual analysis before samples are measured.
Absorbance outside the linear range, stray light, wavelength error, cell mismatch or chemical interaction such as aggregation or pH-dependent absorbance. Checking the absorbance range, cell pairing and solution conditions usually identifies the cause.
Absorbance is proportional to the concentration of the absorbing species and the path length, at a fixed wavelength. This linear relationship allows concentration to be calculated from measured absorbance, provided the solution is dilute and no interfering species absorb.
Wavelength accuracy is checked with holmium oxide or didymium filters, photometric accuracy with potassium dichromate or neutral density filters, and noise and stray light are verified by the manufacturer's procedure. Checks are repeated at defined intervals and after service.
Absorbance depends on path length and the optical quality of the cell. Unmatched or scratched cells add a constant error to every reading, which can shift results even when the chemistry is correct, so cells should be paired and inspected regularly.
Related models


Double-Beam UV-Vis Spectrophotometer for Pharmaceutical Quality Control
制药质量控制双光束紫外可见分光光度计
- CE (to be confirmed)
- +2


Diode-Array UV-Vis Spectrophotometer for Pharmaceutical Analysis
药品分析二极管阵列紫外可见分光光度计
- CE (to be confirmed)
- +2


