Key specifications
| Height adjustment range | 750–1100 mm |
|---|---|
| Camera resolution | 12–20 MP |
| Balance capacity | up to 6 kg, 0.1 g readability |
| Work surface width | 1200–1800 mm |
| Face velocity | 0.3–0.5 m/s |
| Airflow | 800–1500 m³/h |
By Lab Manufacturers China Technical TeamLast reviewed Standards: OSHA 29 CFR 1910.1048 (formaldehyde), ISO 15189, IEC 61010-1
What is the Height-Adjustable Grossing Station with Imaging?
A height-adjustable grossing station with imaging combines an ergonomic table with an overhead or arm-mounted camera, scale and data capture. It is used to photograph specimens, record weights and link gross descriptions to cases.
What is the Height-Adjustable Grossing Station with Imaging?
A height-adjustable grossing station with imaging combines an ergonomic table with an overhead or arm-mounted camera, scale and data capture. It is used to photograph specimens, record weights and link gross descriptions to cases.
Overview
This grossing station adds an electric height adjustment of about 750 to 1100 mm to a ventilated work surface so staff can stand or sit, reducing fatigue. A camera on an arm or overhead boom captures high-resolution images of specimens, often with LED lighting and a scale in the field of view. Integrated balance and barcode scanner link weights, images and case numbers to the laboratory information system. Dictation or voice recognition can be added to record gross descriptions hands-free. Airflow design can be downdraft or backdraft. The system needs network connectivity and data security arrangements, and staff should be trained on image labeling and privacy rules. The added features improve documentation and ergonomics at higher cost than a basic station.
How does it work?
A grossing station protects the operator from formaldehyde and biological hazards by drawing air away from the breathing zone. Downdraft tables pull air through a perforated or slotted work surface into a plenum below, backdraft designs pull air through a rear slot behind the work area, and hooded types use a canopy. Air passes through a duct to the outside or through carbon filters in a ductless unit that captures vapors. Typical face velocities of 0.3 to 0.5 m/s maintain capture. Work surfaces are stainless steel or solid resin, resistant to formalin and disinfectants. A sink with foot or sensor water control, a waste disposal chute, task lighting, a balance and sometimes an overhead camera support workflow. Fans are sized to give quiet operation and adequate airflow without disrupting dissection.
What are the key features?
- Electric height adjustment from about 750 to 1100 mm
- Arm or overhead camera with LED lighting
- Integrated balance and barcode scanner
- Case number linkage to laboratory information systems
- Optional voice dictation for hands-free description
- Downdraft or backdraft ventilation options
What are the technical specifications?
A typical height-adjustable grossing station with imaging configuration offers height adjustment range of 750–1100 mm, camera resolution of 12–20 MP, balance capacity of up to 6 kg, 0.1 g readability, work surface width of 1200–1800 mm, face velocity of 0.3–0.5 m/s and airflow of 800–1500 m³/h. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Height-Adjustable Grossing Station with Imaging is used in specimen photography, surgical pathology grossing, digital pathology workflows and teaching and documentation. Across the wider Grossing Stations class, laboratories also deploy it for surgical pathology grossing, autopsy sample handling and veterinary pathology.
Which standards and certifications apply?
Relevant standards and methods include OSHA 29 CFR 1910.1048 (formaldehyde), ISO 15189, IEC 61010-1, ISO 14644-1 and GBZ 2.1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Test airflow at installation and at least annually, recording face velocity across the work area. Formaldehyde exposure should be measured against local occupational limits, with action levels and monitoring programs in place. Carbon filters in ductless units saturate and must be replaced on schedule, ideally with a vapor sensor. Keep the work surface and drain clean and use compatible disinfectants. Provide makeup air so that room pressure stays balanced. Train staff to work within the capture zone and to keep specimens away from the edge. Dispose of formalin-contaminated waste under hazardous waste rules, and inspect electrical and mechanical parts regularly.
How do I select the right Height-Adjustable Grossing Station with Imaging?
Select the imaging and height-adjustable model if ergonomics, photographic documentation and LIS integration are required. It costs more and needs network planning. Specify height range, camera resolution, balance capacity, barcode and LIS interface, ventilation type and data security.
How does it compare with other Grossing Stations variants?
Choose the airflow design first: downdraft for large specimens and best capture at the work surface, backdraft for bench-style setups, and ductless filtered units where ducting is not possible. Consider table size and height adjustment for ergonomics, sink position, surface material, integrated scales, cameras and lighting. Check airflow and face velocity data, noise level and whether filter life indicators are provided. Ducted systems need exhaust capacity and makeup air, while ductless units need scheduled carbon filter changes and formaldehyde monitoring. Confirm the layout of multiple stations in the room and compliance with workplace exposure limits. Ask for installation, airflow testing and staff training support, and confirm compatibility with laboratory information systems if data capture is included.
Full specifications
| Height adjustment range | 750–1100 mm |
|---|---|
| Camera resolution | 12–20 MP |
| Balance capacity | up to 6 kg, 0.1 g readability |
| Work surface width | 1200–1800 mm |
| Face velocity | 0.3–0.5 m/s |
| Airflow | 800–1500 m³/h |
| Lighting | LED, 1000–1500 lux |
| Interface | Ethernet / USB |
| Power supply | 220 V, 50 Hz, about 0.8 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Specimen photography
- Surgical pathology grossing
- Digital pathology workflows
- Teaching and documentation
Key features
- Electric height adjustment from about 750 to 1100 mm
- Arm or overhead camera with LED lighting
- Integrated balance and barcode scanner
- Case number linkage to laboratory information systems
- Optional voice dictation for hands-free description
- Downdraft or backdraft ventilation options
Frequently asked questions about Height-Adjustable Grossing Station with Imaging
Photographs document size, shape and sectioning sites before tissue is processed, supporting pathology reports, tumor boards and teaching. They also provide a record if review is needed later, so naming and storage policies are essential.
Yes. Staff spend hours at the table, and adjustable height allows standing or seated work at proper elbow height. This reduces back and shoulder strain. Choose a range that fits your team's height and preferred chairs.
Connect the unit to a secure network, use role-based access, encryption where required and follow hospital policy and privacy laws for patient data. Confirm data formats and storage capacity with the IT department before installation.
A grossing station is a ventilated dissection workstation for examining and cutting surgical specimens. It captures formaldehyde vapors and aerosols near the work surface, protecting staff while they describe, measure and sample tissue for processing.
Most designs aim for a face velocity of 0.3 to 0.5 m/s across the work surface, with total airflow of 500 to 1500 m³/h depending on size. Verify with smoke tests and anemometer readings at installation and yearly.
Ductless units with activated carbon or chemical filters can control formaldehyde when filters are replaced on schedule and vapor monitoring is used. They suit rooms where ducting is difficult, but may need more monitoring than ducted systems.