Automated Special Stains Slide Stainer
自动特殊染色玻片染色机
- SKU SLS-0005
- Slide Stainers
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Slides per run | 20–60 |
|---|---|
| Heated station temperature | up to 95 °C |
| Reagent positions | 30–60 |
| Stain protocols supported | PAS, trichrome, Gram, silver, Giemsa |
| Timing resolution | 1 s |
| Dispense volume | 100–400 µL per slide |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1
What is the Automated Special Stains Slide Stainer?
An automated special stains slide stainer runs histochemical stains such as PAS, Masson's trichrome, Gram and silver stains with controlled temperature and timing. It suits laboratories that perform many special stains in addition to routine H and E.
What is the Automated Special Stains Slide Stainer?
An automated special stains slide stainer runs histochemical stains such as PAS, Masson's trichrome, Gram and silver stains with controlled temperature and timing. It suits laboratories that perform many special stains in addition to routine H and E.
Overview
A special stains stainer uses dispensing or dip methods with temperature-controlled reagent positions to run histochemical protocols. Examples include periodic acid-Schiff for glycogen and fungi, Masson's trichrome for collagen, Gram for bacteria and silver methods for reticulin. Slides are processed in batches of 20 to 60, with heated chambers for silver impregnation at 60 °C and other methods requiring precise timing. Reagent consumption is minimized by dispensing exact volumes, and sealed cartridges reduce exposure to hazardous chemicals. Protocol libraries hold a range of validated stains with adjustable parameters. Waste handling is important because silver and heavy metals require special disposal. Compared with manual staining, automation improves reproducibility and saves technician time for time-critical or multi-step methods.
How does it work?
A slide stainer performs a sequence of steps on cut tissue sections. Paraffin is removed with xylene or a substitute, the slides are rehydrated through graded alcohols to water, stained with hematoxylin, differentiated and blued, counterstained with eosin, then dehydrated and cleared for coverslipping. In dip-and-dunk systems a robotic arm or carousel carries slide racks between reagent stations with programmed times, agitation and drying. Reagent-dispensing systems instead apply small volumes of antibody or stain to each slide in a temperature-controlled chamber, which suits immunohistochemistry. Key components are the transport mechanism, reagent containers, heaters, wash stations, fume control and a controller that stores protocols and logs reagent use. Consistent timing and temperature give reproducible staining intensity.
What are the key features?
- Heated reagent positions for silver and heated stains
- Precise timing for multi-step histochemical protocols
- Library of validated special stain protocols
- Exact-volume dispensing reduces reagent waste
- Sealed reagent cartridges limit chemical exposure
- Batch processing of 20 to 60 slides
What are the technical specifications?
A typical automated special stains slide stainer configuration offers slides per run of 20–60, heated station temperature of up to 95 °C, reagent positions of 30–60, stain protocols supported of PAS, trichrome, Gram, silver, Giemsa, timing resolution of 1 s and dispense volume of 100–400 µL per slide. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Special Stains Slide Stainer is used in liver and kidney pathology, microbiology stains on tissue, connective tissue staining and research histochemistry. Across the wider Slide Stainers class, laboratories also deploy it for routine hematoxylin and eosin staining, immunohistochemistry and special stains.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1, ISO 15189, CLSI QMS 02 and ISO 13485. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the stainer in a ventilated area with a carbon filter or exhaust duct and a stable electrical supply. Establish a reagent management program that replaces stains and solvents according to slide counts, and record changes. Keep wash stations clean to prevent precipitate and carry-over, and filter hematoxylin regularly. Validate each protocol with control slides, checking nuclear and cytoplasmic staining balance. Perform daily wipe-down, weekly deep cleaning and annual preventive maintenance. Follow safety rules for solvent and stain handling, with spill kits and training, and follow local regulations for hazardous waste.
How do I select the right Automated Special Stains Slide Stainer?
Choose a special stains stainer when labs run PAS, trichrome, Gram or silver stains frequently and need reproducible timing. For low volumes manual staining may be acceptable. Specify stain list, heated stations, slide capacity, waste handling and whether the reagent system is open, and request protocol validation support.
How does it compare with other Slide Stainers variants?
Match the stainer to the dominant staining type. Routine H and E in high volume favors robotic or carousel dip systems with integrated coverslippers, while immunohistochemistry and in situ hybridization require reagent-dispensing systems with heat retrieval and open or closed reagent options. Consider slide capacity per run, number of reagent stations, flexibility to change protocols and whether special stains are supported. Evaluate reagent use per slide, xylene-free options, fume containment and cleaning requirements. Check connectivity with laboratory information systems, slide labeling, and the maker's validation documents. Match footprint to available bench space and confirm service response times, since stainer downtime delays diagnosis.
Full specifications
| Slides per run | 20–60 |
|---|---|
| Heated station temperature | up to 95 °C |
| Reagent positions | 30–60 |
| Stain protocols supported | PAS, trichrome, Gram, silver, Giemsa |
| Timing resolution | 1 s |
| Dispense volume | 100–400 µL per slide |
| Stored protocols | up to 100 |
| Waste handling | Segregated waste bottles |
| Power supply | 220 V, 50 Hz, about 1.5 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Liver and kidney pathology
- Microbiology stains on tissue
- Connective tissue staining
- Research histochemistry
Key features
- Heated reagent positions for silver and heated stains
- Precise timing for multi-step histochemical protocols
- Library of validated special stain protocols
- Exact-volume dispensing reduces reagent waste
- Sealed reagent cartridges limit chemical exposure
- Batch processing of 20 to 60 slides
Frequently asked questions about Automated Special Stains Slide Stainer
Common automated special stains include PAS, Masson's trichrome, Gram, Giemsa, Alcian blue, reticulin silver and iron stains. Availability depends on the stainer and reagent system, so confirm the stain list with the supplier.
Yes. Silver-containing solutions are hazardous waste and should be collected separately and disposed of under local regulations. Instruments with segregated waste bottles simplify compliance and protect drains.
When validated, automated protocols typically match or exceed manual reproducibility. Validate with positive and negative control tissues and have pathologists approve staining quality before adopting each method into routine service.
A slide stainer automatically stains tissue sections on glass slides. It removes paraffin, rehydrates the tissue, applies stains such as hematoxylin and eosin or antibodies, then rinses and dehydrates the slide, giving consistent results with less manual handling.
Capacity ranges from about 20 slides for small benchtop units to more than 300 slides per run for carousel or robotic systems. Throughput in a day depends on protocol length, which is typically 15 to 40 minutes for H and E.
Usually not well. H and E stainers use dip or carousel methods with bulk reagents, while immunohistochemistry needs individual slide reagent application and heat retrieval. Some laboratories use two separate instruments to optimize quality and throughput.