What are Slide Stainers?

Slide stainers automate the staining of tissue sections on glass slides by moving them through dewaxing, stain and rinse reagents or by dispensing reagents onto each slide. Pathology laboratories use them for hematoxylin and eosin, special stains and immunohistochemistry, with capacities from 20 to over 300 slides per run.

5 models of Slide Stainers

The 5 models below are current configurations; specifications are confirmed on quotation.

Linear Dip Slide Stainer

线性浸染式玻片染色机

  • SLS-0001
  • Slide Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Slides per rack:
20–30
Stations:
20–30
Throughput:
200–400 slides/h
Racks in process:
up to 8
Dwell time:
1 s–99 min
Oven / drying stations:
1–2

A linear dip slide stainer transports racks of slides along a row of reagent stations with a robotic arm, following programmed times. It is used for high-volume routine H and E staining and can be fitted with an inline coverslipper.

Request a quote
View details

Carousel Slide Stainer

转盘式玻片染色机

  • SLS-0002
  • Slide Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Slides per basket:
20–30
Baskets per run:
1–2
Reagent dishes:
16–24
Throughput:
60–120 slides/h
Dwell time:
1 s–99 min
Stored protocols:
up to 20

A carousel slide stainer rotates a basket of slides between reagent dishes arranged in a circle. It provides a compact, economical solution for medium-volume routine H and E staining, with straightforward operation and easy cleaning.

Request a quote
View details

Integrated Stainer-Coverslipper Workstation

染色封片一体化工作站

  • SLS-0003
  • Slide Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Throughput:
100–300 slides/h
Slides per rack:
20–30
Coverslip type:
Glass or plastic film
Reagent stations:
18–28
Stored protocols:
up to 50
Barcode reading:
1D / 2D slide labels

An integrated stainer-coverslipper workstation combines automated H and E staining with film or glass coverslipping in one continuous workflow. It is aimed at laboratories that want to reduce handling and move slides straight to microscopy.

Request a quote
View details

Automated IHC Slide Stainer

自动免疫组化玻片染色机

  • SLS-0004
  • Slide Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Slides per run:
30–60
Retrieval temperature:
up to 100 °C
Incubation temperature:
25–42 °C
Dispense volume:
100–300 µL per slide
Reagent positions:
up to 60
Protocols:
up to 100

An automated IHC slide stainer applies primary and secondary antibodies and detection reagents to each slide in a controlled-temperature chamber, often with heat-induced epitope retrieval. It is used for diagnostic and research immunohistochemistry and in situ hybridization.

Request a quote
View details

Automated Special Stains Slide Stainer

自动特殊染色玻片染色机

  • SLS-0005
  • Slide Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Slides per run:
20–60
Heated station temperature:
up to 95 °C
Reagent positions:
30–60
Stain protocols supported:
PAS, trichrome, Gram, silver, Giemsa
Timing resolution:
1 s
Dispense volume:
100–400 µL per slide

An automated special stains slide stainer runs histochemical stains such as PAS, Masson's trichrome, Gram and silver stains with controlled temperature and timing. It suits laboratories that perform many special stains in addition to routine H and E.

Request a quote
View details

Compare Slide Stainers models

ModelSlides per rackThroughputDwell timeStored protocolsDimensions (W×D×H)
Linear Dip Slide StainerSLS-000120–30200–400 slides/h1 s–99 minup to 50about 1800 × 700 × 800 mm
Carousel Slide StainerSLS-0002—60–120 slides/h1 s–99 minup to 20about 600 × 600 × 500 mm
Integrated Stainer-Coverslipper WorkstationSLS-000320–30100–300 slides/h—up to 50about 1600 × 800 × 800 mm
Automated IHC Slide StainerSLS-0004—————
Automated Special Stains Slide StainerSLS-0005———up to 100—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Slide Stainers work?

A slide stainer performs a sequence of steps on cut tissue sections. Paraffin is removed with xylene or a substitute, the slides are rehydrated through graded alcohols to water, stained with hematoxylin, differentiated and blued, counterstained with eosin, then dehydrated and cleared for coverslipping. In dip-and-dunk systems a robotic arm or carousel carries slide racks between reagent stations with programmed times, agitation and drying. Reagent-dispensing systems instead apply small volumes of antibody or stain to each slide in a temperature-controlled chamber, which suits immunohistochemistry. Key components are the transport mechanism, reagent containers, heaters, wash stations, fume control and a controller that stores protocols and logs reagent use. Consistent timing and temperature give reproducible staining intensity.

Which Slide Stainers variants are available?

  • Linear Dip Slide Stainer — A linear dip slide stainer transports racks of slides along a row of reagent stations with a robotic arm, following programmed times.
  • Carousel Slide Stainer — A carousel slide stainer rotates a basket of slides between reagent dishes arranged in a circle.
  • Integrated Stainer-Coverslipper Workstation — An integrated stainer-coverslipper workstation combines automated H and E staining with film or glass coverslipping in one continuous workflow.
  • Automated IHC Slide Stainer — An automated IHC slide stainer applies primary and secondary antibodies and detection reagents to each slide in a controlled-temperature chamber, often with heat-induced epitope retrieval.
  • Automated Special Stains Slide Stainer — An automated special stains slide stainer runs histochemical stains such as PAS, Masson's trichrome, Gram and silver stains with controlled temperature and timing.

How do I choose the right variant?

Match the stainer to the dominant staining type. Routine H and E in high volume favors robotic or carousel dip systems with integrated coverslippers, while immunohistochemistry and in situ hybridization require reagent-dispensing systems with heat retrieval and open or closed reagent options. Consider slide capacity per run, number of reagent stations, flexibility to change protocols and whether special stains are supported. Evaluate reagent use per slide, xylene-free options, fume containment and cleaning requirements. Check connectivity with laboratory information systems, slide labeling, and the maker's validation documents. Match footprint to available bench space and confirm service response times, since stainer downtime delays diagnosis.

Where are Slide Stainers used?

Slide Stainers are specified in routine hematoxylin and eosin staining, immunohistochemistry, special stains, in situ hybridization and research histology.

Which standards and certifications apply?

Work with Slide Stainers is commonly governed by IEC 61010-1, IEC 61010-2-101, IEC 61326-1, ISO 15189, CLSI QMS 02 and ISO 13485. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Install the stainer in a ventilated area with a carbon filter or exhaust duct and a stable electrical supply. Establish a reagent management program that replaces stains and solvents according to slide counts, and record changes. Keep wash stations clean to prevent precipitate and carry-over, and filter hematoxylin regularly. Validate each protocol with control slides, checking nuclear and cytoplasmic staining balance. Perform daily wipe-down, weekly deep cleaning and annual preventive maintenance. Follow safety rules for solvent and stain handling, with spill kits and training, and follow local regulations for hazardous waste.

Frequently asked questions about Slide Stainers

A slide stainer automatically stains tissue sections on glass slides. It removes paraffin, rehydrates the tissue, applies stains such as hematoxylin and eosin or antibodies, then rinses and dehydrates the slide, giving consistent results with less manual handling.