Backdraft Grossing Station
后吸式取材台
- SKU GRS-0002
- Grossing Stations
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Work surface width | 900–1500 mm |
|---|---|
| Work surface depth | 600–750 mm |
| Slot face velocity | 0.4–0.6 m/s |
| Airflow | 500–1000 m³/h |
| Surface material | 304 stainless steel |
| Sink | Integrated, with tap |
By Lab Manufacturers China Technical TeamLast reviewed Standards: OSHA 29 CFR 1910.1048 (formaldehyde), ISO 15189, IEC 61010-1
What is the Backdraft Grossing Station?
A backdraft grossing station draws air through a slot at the back of the work area and sometimes across the top, directing vapors away from the operator. It suits routine surgical grossing of small to medium specimens at a bench-style workstation.
What is the Backdraft Grossing Station?
A backdraft grossing station draws air through a slot at the back of the work area and sometimes across the top, directing vapors away from the operator. It suits routine surgical grossing of small to medium specimens at a bench-style workstation.
Overview
A backdraft grossing station uses a rear plenum with slots or a baffle that draws air horizontally across the work surface, typically at 0.4 to 0.6 m/s at the slot. A raised back panel and side walls can help direct air and protect from splashes. Work surfaces measure 900 to 1500 mm wide and are fitted with a sink, cutting board holder and lighting. The design is more compact and often lower in cost than a downdraft table, but it is less effective for large specimens, where the body blocks airflow. Installation may be ducted or ductless with carbon filters. Users should keep specimens close to the rear slot and avoid leaning over the work. Regular airflow checks and careful layout improve capture.
How does it work?
A grossing station protects the operator from formaldehyde and biological hazards by drawing air away from the breathing zone. Downdraft tables pull air through a perforated or slotted work surface into a plenum below, backdraft designs pull air through a rear slot behind the work area, and hooded types use a canopy. Air passes through a duct to the outside or through carbon filters in a ductless unit that captures vapors. Typical face velocities of 0.3 to 0.5 m/s maintain capture. Work surfaces are stainless steel or solid resin, resistant to formalin and disinfectants. A sink with foot or sensor water control, a waste disposal chute, task lighting, a balance and sometimes an overhead camera support workflow. Fans are sized to give quiet operation and adequate airflow without disrupting dissection.
What are the key features?
- Rear slot plenum draws air across the work surface
- Raised back panel and side walls for splash protection
- Work surface width of 900 to 1500 mm
- Integrated sink and cutting board holder
- Ducted or ductless carbon-filtered operation
- Compact, lower-cost bench-style design
What are the technical specifications?
A typical backdraft grossing station configuration offers work surface width of 900–1500 mm, work surface depth of 600–750 mm, slot face velocity of 0.4–0.6 m/s, airflow of 500–1000 m³/h, surface material of 304 stainless steel and sink of Integrated, with tap. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Backdraft Grossing Station is used in routine surgical grossing, biopsy trimming, veterinary pathology and small laboratory settings. Across the wider Grossing Stations class, laboratories also deploy it for surgical pathology grossing, autopsy sample handling and veterinary pathology.
Which standards and certifications apply?
Relevant standards and methods include OSHA 29 CFR 1910.1048 (formaldehyde), ISO 15189, IEC 61010-1, ISO 14644-1 and GBZ 2.1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Test airflow at installation and at least annually, recording face velocity across the work area. Formaldehyde exposure should be measured against local occupational limits, with action levels and monitoring programs in place. Carbon filters in ductless units saturate and must be replaced on schedule, ideally with a vapor sensor. Keep the work surface and drain clean and use compatible disinfectants. Provide makeup air so that room pressure stays balanced. Train staff to work within the capture zone and to keep specimens away from the edge. Dispose of formalin-contaminated waste under hazardous waste rules, and inspect electrical and mechanical parts regularly.
How do I select the right Backdraft Grossing Station?
Choose backdraft for routine small to medium specimens where space and cost matter. For large organs, consider downdraft. Specify surface width, slot velocity, ducted or ductless option, sink, lighting and noise, and verify capture with smoke tests in the installed position.
How does it compare with other Grossing Stations variants?
Choose the airflow design first: downdraft for large specimens and best capture at the work surface, backdraft for bench-style setups, and ductless filtered units where ducting is not possible. Consider table size and height adjustment for ergonomics, sink position, surface material, integrated scales, cameras and lighting. Check airflow and face velocity data, noise level and whether filter life indicators are provided. Ducted systems need exhaust capacity and makeup air, while ductless units need scheduled carbon filter changes and formaldehyde monitoring. Confirm the layout of multiple stations in the room and compliance with workplace exposure limits. Ask for installation, airflow testing and staff training support, and confirm compatibility with laboratory information systems if data capture is included.
Full specifications
| Work surface width | 900–1500 mm |
|---|---|
| Work surface depth | 600–750 mm |
| Slot face velocity | 0.4–0.6 m/s |
| Airflow | 500–1000 m³/h |
| Surface material | 304 stainless steel |
| Sink | Integrated, with tap |
| Noise level | ≤ 58 dB(A) |
| Lighting | LED, about 800 lux |
| Power supply | 220 V, 50 Hz, about 0.4 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine surgical grossing
- Biopsy trimming
- Veterinary pathology
- Small laboratory settings
Key features
- Rear slot plenum draws air across the work surface
- Raised back panel and side walls for splash protection
- Work surface width of 900 to 1500 mm
- Integrated sink and cutting board holder
- Ducted or ductless carbon-filtered operation
- Compact, lower-cost bench-style design
Frequently asked questions about Backdraft Grossing Station
For small and medium specimens held near the rear slot it can be effective, but the operator's body can disturb airflow. For large specimens downdraft usually gives better capture, so match design to the specimen mix.
Keep specimens and cutting boards within about 15 to 30 cm of the rear slot so vapors are drawn away quickly. Working at the front edge of the bench reduces capture and increases exposure risk for the operator.
Yes, many are available with a filtration module using activated carbon. Choose this option when ducts are not possible, and plan a filter replacement schedule with a sensor or scheduled tests for saturation.
A grossing station is a ventilated dissection workstation for examining and cutting surgical specimens. It captures formaldehyde vapors and aerosols near the work surface, protecting staff while they describe, measure and sample tissue for processing.
Most designs aim for a face velocity of 0.3 to 0.5 m/s across the work surface, with total airflow of 500 to 1500 m³/h depending on size. Verify with smoke tests and anemometer readings at installation and yearly.
Ductless units with activated carbon or chemical filters can control formaldehyde when filters are replaced on schedule and vapor monitoring is used. They suit rooms where ducting is difficult, but may need more monitoring than ducted systems.