Ductless Filtered Grossing Station
无管过滤式取材台
- SKU GRS-0003
- Grossing Stations
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Airflow | 400–900 m³/h |
|---|---|
| Face velocity | 0.3–0.5 m/s |
| Filter type | Activated carbon with HEPA prefilter |
| Filter life | approx. 3–6 months at typical loads |
| Work surface width | 900–1500 mm |
| Surface material | 304 stainless steel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: OSHA 29 CFR 1910.1048 (formaldehyde), ISO 15189, IEC 61010-1
What is the Ductless Filtered Grossing Station?
A ductless filtered grossing station recirculates air through activated carbon or chemical filters that adsorb formaldehyde and solvent vapors. It is used where exterior ducting is impractical, such as leased premises or upper floors.
What is the Ductless Filtered Grossing Station?
A ductless filtered grossing station recirculates air through activated carbon or chemical filters that adsorb formaldehyde and solvent vapors. It is used where exterior ducting is impractical, such as leased premises or upper floors.
Overview
A ductless grossing station pulls air through the work surface or a rear slot and passes it through a multilayer filter of activated carbon impregnated for formaldehyde, often with a prefilter for particles, before returning clean air to the room. Airflow is typically 400 to 900 m³/h with face velocity around 0.3 to 0.5 m/s. A vapor sensor can warn when filter capacity is nearly used, prompting replacement, and filters usually last several months depending on workload. Work surfaces are stainless steel and similar to ducted models. The benefits are installation flexibility and lower heat loss through exhaust, while the cost of filters and the need for monitoring are the trade-offs. Room air testing and a filter management program are needed to ensure exposure limits are met.
How does it work?
A grossing station protects the operator from formaldehyde and biological hazards by drawing air away from the breathing zone. Downdraft tables pull air through a perforated or slotted work surface into a plenum below, backdraft designs pull air through a rear slot behind the work area, and hooded types use a canopy. Air passes through a duct to the outside or through carbon filters in a ductless unit that captures vapors. Typical face velocities of 0.3 to 0.5 m/s maintain capture. Work surfaces are stainless steel or solid resin, resistant to formalin and disinfectants. A sink with foot or sensor water control, a waste disposal chute, task lighting, a balance and sometimes an overhead camera support workflow. Fans are sized to give quiet operation and adequate airflow without disrupting dissection.
What are the key features?
- Activated carbon filters impregnated for formaldehyde
- Particle prefilter protects the main filter
- Vapor sensor with filter saturation alert
- Airflow of 400 to 900 m³/h
- No external duct required
- Stainless steel work surface with sink
What are the technical specifications?
A typical ductless filtered grossing station configuration offers airflow of 400–900 m³/h, face velocity of 0.3–0.5 m/s, filter type of Activated carbon with HEPA prefilter, filter life of approx. 3–6 months at typical loads, work surface width of 900–1500 mm and surface material of 304 stainless steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Ductless Filtered Grossing Station is used in leased or upper-floor laboratories, small pathology laboratories, veterinary clinics and temporary grossing areas. Across the wider Grossing Stations class, laboratories also deploy it for surgical pathology grossing, autopsy sample handling and veterinary pathology.
Which standards and certifications apply?
Relevant standards and methods include OSHA 29 CFR 1910.1048 (formaldehyde), ISO 15189, IEC 61010-1, ISO 14644-1 and GBZ 2.1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Test airflow at installation and at least annually, recording face velocity across the work area. Formaldehyde exposure should be measured against local occupational limits, with action levels and monitoring programs in place. Carbon filters in ductless units saturate and must be replaced on schedule, ideally with a vapor sensor. Keep the work surface and drain clean and use compatible disinfectants. Provide makeup air so that room pressure stays balanced. Train staff to work within the capture zone and to keep specimens away from the edge. Dispose of formalin-contaminated waste under hazardous waste rules, and inspect electrical and mechanical parts regularly.
How do I select the right Ductless Filtered Grossing Station?
Choose a ductless station where ducting is impractical and workload is modest. It needs filter monitoring and replacement, so running costs are higher. Specify filter type and life, vapor sensor, airflow, surface and noise, and ask for formaldehyde capture test data and filter replacement cost.
How does it compare with other Grossing Stations variants?
Choose the airflow design first: downdraft for large specimens and best capture at the work surface, backdraft for bench-style setups, and ductless filtered units where ducting is not possible. Consider table size and height adjustment for ergonomics, sink position, surface material, integrated scales, cameras and lighting. Check airflow and face velocity data, noise level and whether filter life indicators are provided. Ducted systems need exhaust capacity and makeup air, while ductless units need scheduled carbon filter changes and formaldehyde monitoring. Confirm the layout of multiple stations in the room and compliance with workplace exposure limits. Ask for installation, airflow testing and staff training support, and confirm compatibility with laboratory information systems if data capture is included.
Full specifications
| Airflow | 400–900 m³/h |
|---|---|
| Face velocity | 0.3–0.5 m/s |
| Filter type | Activated carbon with HEPA prefilter |
| Filter life | approx. 3–6 months at typical loads |
| Work surface width | 900–1500 mm |
| Surface material | 304 stainless steel |
| Vapor sensor | Formaldehyde, 0–10 ppm |
| Noise level | ≤ 60 dB(A) |
| Power supply | 220 V, 50 Hz, about 0.5 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Leased or upper-floor laboratories
- Small pathology laboratories
- Veterinary clinics
- Temporary grossing areas
Key features
- Activated carbon filters impregnated for formaldehyde
- Particle prefilter protects the main filter
- Vapor sensor with filter saturation alert
- Airflow of 400 to 900 m³/h
- No external duct required
- Stainless steel work surface with sink
Frequently asked questions about Ductless Filtered Grossing Station
Filter life depends on formalin use and airflow, typically three to six months at moderate workloads. Use a vapor sensor or routine air tests to decide replacement, since saturated filters release vapors back into the room.
It can be, when the filter is matched to formaldehyde, airflow is verified and monitoring is in place. Lack of filter management is the main risk, so a documented replacement schedule and exposure testing are essential.
Because air is returned to the room, makeup air needs are lower than with ducted systems, but general ventilation is still necessary for comfort and for vapors escaping capture. Consult building ventilation guidance.
A grossing station is a ventilated dissection workstation for examining and cutting surgical specimens. It captures formaldehyde vapors and aerosols near the work surface, protecting staff while they describe, measure and sample tissue for processing.
Most designs aim for a face velocity of 0.3 to 0.5 m/s across the work surface, with total airflow of 500 to 1500 m³/h depending on size. Verify with smoke tests and anemometer readings at installation and yearly.
Ductless units with activated carbon or chemical filters can control formaldehyde when filters are replaced on schedule and vapor monitoring is used. They suit rooms where ducting is difficult, but may need more monitoring than ducted systems.
Related models