Headspace Gas Chromatograph
顶空气相色谱仪
- SKU GAC-0004
- Gas Chromatography
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Vial capacity | 12–120 vials (10 or 20 mL) |
|---|---|
| Oven temperature range | 40–300 °C |
| Transfer line and valve temperature | up to 200 °C |
| Sample loop volume | 1–3 mL |
| Equilibration time setting | 0–999 min |
| Temperature stability | ±0.1 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <621>, USP <467>, Ph. Eur. 2.2.28
What is the Headspace Gas Chromatograph?
A headspace gas chromatograph combines a thermostatted headspace sampler with a GC, analyzing the vapor above a sealed vial rather than injecting the sample matrix. It is chosen for residual solvents, blood alcohol and volatile organics in solids, liquids and polymers, where direct injection would contaminate the system.
What is the Headspace Gas Chromatograph?
A headspace gas chromatograph combines a thermostatted headspace sampler with a GC, analyzing the vapor above a sealed vial rather than injecting the sample matrix. It is chosen for residual solvents, blood alcohol and volatile organics in solids, liquids and polymers, where direct injection would contaminate the system.
Overview
In static headspace, a sample is sealed in a 10–22 mL vial and heated at 40–200 °C until volatile compounds reach equilibrium between the matrix and the gas phase. A portion of the vapor is then transferred to the GC by pressure-balanced loop, pressurized syringe or gas-tight syringe. Non-volatile matrix stays in the vial, which keeps inlet liners and columns clean and extends maintenance intervals. Samplers hold 12–120 vials with agitation, and transfer lines are heated up to 200 °C to prevent condensation. Sensitivity depends on partition coefficient, phase ratio, temperature and salt addition; salting out improves recovery of polar analytes in water. The technique is specified in USP <467> for residual solvents, in forensic blood alcohol methods, and for volatile monomers in polymers. Dynamic headspace and trap variants exist for ultra-trace work but are separate configurations.
How does it work?
A gas chromatograph injects a liquid or gas sample into a heated inlet, commonly split/splitless at 150–350 °C, where it vaporizes and mixes with carrier gas such as helium, hydrogen or nitrogen. The vapor passes through a capillary column, typically 15–60 m long, 0.25 mm internal diameter, coated with a polysiloxane or polyethylene glycol film of 0.1–1.0 µm. Analytes partition between gas and film according to volatility and polarity. A programmable oven ramps temperature, often from 40 to 300 °C, eluting compounds in boiling-point order. Detectors respond differently: the flame ionization detector senses carbon-containing compounds, the thermal conductivity detector responds to all gases, the electron capture detector to electronegative halogens, and mass spectrometers give identification. Electronic pneumatic control regulates pressure and flow to keep retention times reproducible.
What are the key features?
- Thermostatted oven holding 12–120 vials with programmable agitation and equilibration time
- Pressure-balanced loop or syringe injection giving repeatability below 1.5% RSD
- Heated transfer line and valve up to 200 °C preventing analyte condensation
- Vial pressurization control compensating for differences in headspace volume
- FID or mass spectrometer detection for residual solvent and volatile organic analysis
What are the technical specifications?
A typical headspace gas chromatograph configuration offers vial capacity of 12–120 vials (10 or 20 mL), oven temperature range of 40–300 °C, transfer line and valve temperature of up to 200 °C, sample loop volume of 1–3 mL, equilibration time setting of 0–999 min and temperature stability of ±0.1 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Headspace Gas Chromatograph is used in residual solvents per USP <467>, blood alcohol and forensic volatiles, volatile monomers in polymers and packaging, flavor and fragrance volatile profiling and volatile organic compounds in soil and water. Across the wider Gas Chromatography class, laboratories also deploy it for residual solvent testing in pharmaceuticals, petrochemical hydrocarbon and purity analysis and environmental volatile organic compounds.
Which standards and certifications apply?
Relevant standards and methods include USP <621>, USP <467>, Ph. Eur. 2.2.28, ASTM D6729, ASTM D5134, US EPA Method 8015, ISO 6974, ChP 0521 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Provide high-purity carrier and detector gases, at least 99.999%, with moisture, oxygen and hydrocarbon traps, and install leak-tight fittings since oxygen damages columns at high temperature. If hydrogen is used, install a hydrogen sensor and follow flammable gas safety requirements. Condition new columns following the manufacturer's procedure and respect maximum temperature limits. Replace septa, inlet liners and O-rings regularly, and trim the column inlet to restore peak shape. Verify oven temperature, flow and detector sensitivity during qualification under USP <1058>. Ventilate exhaust, particularly when analyzing toxic solvents, and keep a stable laboratory temperature for electronic pneumatics.
How do I select the right Headspace Gas Chromatograph?
Select headspace GC when matrices are dirty, solid or aqueous and analytes are volatile. It is not suitable for semi-volatile or thermally labile compounds. In an RFQ specify vial capacity and size, maximum oven temperature, transfer mode, loop volume, detector type and the compendial methods, such as USP <467> or ChP 0861, to be run.
How does it compare with other Gas Chromatography variants?
Choose the detector first, because it defines what you can measure. FID covers hydrocarbons, solvents and most organic compounds at ppm to ppb levels; ECD is selective for halogenated pesticides and PCBs at ppt levels; TCD is universal and suits permanent gases and percent-level analysis. Headspace sampling is selected for volatile analytes in solid or liquid matrices without injecting the matrix. Portable GC suits field screening. Then consider inlet type, number of detectors, oven ramp rate, electronic pneumatic control precision, autosampler capacity, and carrier gas availability, since hydrogen generators can replace helium. Confirm software support for regulatory reporting, and compare column compatibility with your validated methods, including ASTM, EPA or pharmacopoeial procedures that specify particular phases and dimensions.
Full specifications
| Vial capacity | 12–120 vials (10 or 20 mL) |
|---|---|
| Oven temperature range | 40–300 °C |
| Transfer line and valve temperature | up to 200 °C |
| Sample loop volume | 1–3 mL |
| Equilibration time setting | 0–999 min |
| Temperature stability | ±0.1 °C |
| Injection repeatability (RSD) | ≤1.5% |
| Carryover | ≤0.05% |
| Agitation | Programmable, 250–750 rpm |
| GC detector options | FID, MS, ECD |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Residual solvents per USP <467>
- Blood alcohol and forensic volatiles
- Volatile monomers in polymers and packaging
- Flavor and fragrance volatile profiling
- Volatile organic compounds in soil and water
Key features
- Thermostatted oven holding 12–120 vials with programmable agitation and equilibration time
- Pressure-balanced loop or syringe injection giving repeatability below 1.5% RSD
- Heated transfer line and valve up to 200 °C preventing analyte condensation
- Vial pressurization control compensating for differences in headspace volume
- FID or mass spectrometer detection for residual solvent and volatile organic analysis
Frequently asked questions about Headspace Gas Chromatograph
Residual solvents are volatile while drug substances and excipients are not. Sampling the vapor above a heated vial introduces only the solvents to the GC, protecting the column and inlet from non-volatile matrix and giving reproducible results, as specified in USP <467>.
Higher equilibration temperature raises vapor pressure and shifts analytes into the gas phase, generally increasing peak area. The limit is solvent boiling point and analyte stability, and temperatures are usually kept 10–20 °C below the matrix boiling point. Pressurized vials allow higher temperatures.
Loop systems pressurize the vial, fill a fixed-volume loop and inject through a valve, giving excellent repeatability. Syringe systems draw a set volume with a heated gas-tight syringe, offering flexibility and lower cost but slightly less precision and potential adsorption.
Gas chromatography analyzes compounds that can be vaporized without decomposing, generally with boiling points below about 400 °C and molecular weights under roughly 500 Da. This includes hydrocarbons, solvents, pesticides, fatty acid esters and permanent gases. Polar or non-volatile compounds may need derivatization.
Helium is inert and widely specified in methods, but supply is variable. Hydrogen gives faster separations at optimum linear velocity and can be produced by a generator, but requires safety measures. Nitrogen is cheapest and suits some detectors but gives slower analysis and lower efficiency at high flows.
Split injection vents most of the vaporized sample, typically at ratios of 10:1 to 100:1, to prevent column overload with concentrated samples. Splitless injection transfers nearly the entire sample to the column for trace analysis, but requires solvent focusing and a longer inlet residence time.