Open-Loop Flow-Through Dissolution System (USP Apparatus 4)
开环流通池溶出系统(USP 装置 4)
- CE (to be confirmed)
- +1
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

闭环流通池溶出系统
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Apparatus type | USP Apparatus 4, closed loop |
|---|---|
| Number of cells | 6–8 |
| Reservoir volume | 100–1000 mL |
| Flow rate | 8–16 mL/min |
| Pulse rate | 120 ± 10 pulses/min |
| Temperature control | 37.0 ± 0.5 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <1092>, Ph. Eur. 2.9.3
A closed-loop flow-through dissolution system recirculates a fixed volume of medium through the cell and back to a reservoir, so concentration builds up over time. It suits low-dose products and small-volume tests where medium use and waste must be limited.
A closed-loop flow-through dissolution system recirculates a fixed volume of medium through the cell and back to a reservoir, so concentration builds up over time. It suits low-dose products and small-volume tests where medium use and waste must be limited.
In closed-loop mode, medium circulates from a reservoir through the flow cell and back, typically at 8 to 16 mL/min with a total volume of 100 to 1000 mL. Since dissolved drug accumulates in the reservoir, the concentration can be sampled manually from the reservoir or measured continuously by a UV flow cell, making it suitable for low-dose tablets whose released concentration is detectable in the small volume. The same pump and cells used for open-loop tests are configured with a switching valve or dedicated tubing. Closed-loop operation behaves like a paddle test in terms of concentration but retains the gentle, reproducible hydrodynamics of the cell. It is frequently used for low-dose products, for testing with small medium volumes such as expensive buffers or biorelevant media, and for routine tests where cost of medium disposal matters. Sink conditions must be confirmed because saturation may develop.
A flow-through system uses a piston pump to deliver medium at a controlled flow rate, typically 4–16 mL/min, with a sinusoidal pulse of 120 ± 10 pulses per minute, upward through a vertical cell. The dosage form sits on a bed of glass beads, which stabilize laminar flow, and a filter at the top retains particles. The medium can go once through the cell (open loop), so fresh solvent continually maintains sink conditions, or return to a reservoir (closed loop). Because the cell is stationary, hydrodynamics are mild and reproducible, and the medium can be changed programmatically to create pH profiles. Key components are the pump, cells of 12 or 22.6 mm diameter, a heated bath holding 37 °C, filter heads, and a collector or detector. Release follows diffusion and erosion kinetics, and flow rate determines the boundary layer thickness around the dosage form.
A typical closed-loop flow-through dissolution system configuration offers apparatus type of USP Apparatus 4, closed loop, number of cells of 6–8, reservoir volume of 100–1000 mL, flow rate of 8–16 mL/min, pulse rate of 120 ± 10 pulses/min and temperature control of 37.0 ± 0.5 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Closed-Loop Flow-Through Dissolution System is used in low-dose tablet dissolution, biorelevant media testing, routine QC with reduced waste and method development. Across the wider Flow-Through Systems class, laboratories also deploy it for extended-release product QC, poorly soluble drug testing and stent and implant release studies.
Relevant standards and methods include USP <711>, USP <1092>, Ph. Eur. 2.9.3, JP 6.10, ChP 0931, USP <724> and FDA Guidance on Dissolution Testing of Immediate Release Solid Oral Dosage Forms. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Degas media and prime the pump to remove air, since bubbles in cells cause flow variation and filter blockage. Verify flow rate gravimetrically and check pulse rate at installation and regularly. Use calibrated thermometers to confirm cell temperature at 37.0 ± 0.5 °C. Clean cells, beads and filters after each run and replace worn pump seals or check valves. Keep tubing lengths short to limit dead volume. Qualification should include IQ/OQ, flow calibration and dissolution performance verification using reference tablets. For regulated work, ensure software supports audit trail and data integrity.
Choose closed-loop when medium volume is limited, doses are low, or waste disposal costs matter. Specify reservoir volume range, pump flow accuracy, UV interface and valve type. For poorly soluble actives that need constant sink, select the open-loop version or a dual-mode system. Confirm the expected test duration and reservoir capacity.
Choose by the nature of the product and the regulatory requirement. Open-loop suits poorly soluble actives and extended-release forms needing sink conditions; closed-loop suits low-dose tablets and small media volumes. Implants, stents and microspheres need specialty cells and low flow rates. For high throughput or unattended runs, pick an automated multi-channel system with fraction collection and audit trail. A retrofit module is the lowest-cost route to meet an Apparatus 4 monograph. Evaluate flow accuracy (±5% or better), pulse rate control, cell diameter options, wetted-part material, number of channels and software data integrity features. Also consider medium volume and waste because open-loop runs can consume many liters.
| Apparatus type | USP Apparatus 4, closed loop |
|---|---|
| Number of cells | 6–8 |
| Reservoir volume | 100–1000 mL |
| Flow rate | 8–16 mL/min |
| Pulse rate | 120 ± 10 pulses/min |
| Temperature control | 37.0 ± 0.5 °C |
| Cell diameter | 12 mm and 22.6 mm |
| Detection | manual sampling or UV flow cell |
| Mixing | reservoir stirrer, optional |
| Power supply | 220 V AC, 50/60 Hz, about 0.8 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Not directly. Both accumulate drug in a fixed medium volume, but the flow cell provides gentler, more reproducible hydrodynamics. Method equivalence must be demonstrated during development before replacing a paddle method.
Typical closed-loop volumes are 100 to 1000 mL, depending on the dose and the detection limit. A smaller volume increases concentration and sensitivity but raises the risk of approaching saturation.
Yes, many systems include a switching valve so the same pump and cells can run open or closed loop. Check that valve dead volume and tubing are validated for both modes.
It is a dissolution apparatus, USP Apparatus 4, in which medium is pumped through a vertical cell holding the dosage form. The medium either passes once (open loop) or recirculates (closed loop), providing gentle, reproducible hydrodynamics.
It is preferred for poorly soluble drugs needing sink conditions, for implants and stents, for extended-release forms, and for testing where medium changes are needed without handling the sample.
Compendial methods typically use 4, 8 or 16 mL/min with a pulsation of 120 ± 10 pulses per minute. Specialty methods for implants may use lower flow rates of 0.1 to 4 mL/min.