Helium Sparging Dissolution Media Degassing Station
氦气鼓泡溶出介质脱气站
- SKU MEP-0003
- Media Preparation
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Gas type | helium, purity ≥ 99.995% |
|---|---|
| Gas pressure | 0.1–0.3 MPa regulated |
| Flow rate | 0.1–2 L/min per outlet |
| Outlets | 1–6 |
| Sparging time | 5–15 min typical |
| Sparger material | fritted glass or 316 stainless steel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <791>, USP <1092>
What is the Helium Sparging Dissolution Media Degassing Station?
A helium sparging station degasses dissolution medium by bubbling high-purity helium through it, displacing dissolved air without heating or filtration. It is used for temperature-sensitive media and for methods that specify helium degassing. It is used where heating is undesirable.
What is the Helium Sparging Dissolution Media Degassing Station?
A helium sparging station degasses dissolution medium by bubbling high-purity helium through it, displacing dissolved air without heating or filtration. It is used for temperature-sensitive media and for methods that specify helium degassing. It is used where heating is undesirable.
Overview
The station delivers high-purity helium at a regulated pressure through a fritted glass or stainless steel sparger into the medium reservoir or directly into the vessels. Because helium has very low solubility in aqueous media, bubbling for typically 5 to 15 minutes displaces oxygen and nitrogen efficiently. The system includes a pressure regulator, flow meter, gas manifold with one to six outputs, and a cover or vent to handle exhaust. It avoids heating, which benefits heat-labile actives or media containing volatile components, and it avoids membrane filtration, so it is useful for media containing surfactants that foam under vacuum. Helium is consumed continuously while sparging, so gas cost and cylinder handling must be considered. A dissolved-oxygen probe can verify results. Helium sparging gives a fast, repeatable degassing endpoint and is often used in HPLC mobile phase preparation as well as dissolution.
How does it work?
Dissolution media such as 0.1 N HCl, pH 4.5 acetate buffer and pH 6.8 phosphate buffer must have correct composition, pH, volume, temperature and dissolved gas content. Preparation equipment automates these steps. Proportioning pumps or valves mix concentrate and purified water; pH electrodes and conductivity cells verify composition; degassing removes dissolved gases by vacuum with heat, vacuum membranes, or helium sparging, since gas bubbles on tablets or baskets change local hydrodynamics and surface area; and volumetric dispensers fill vessels to ±1% at 37–41 °C. Gas solubility falls with temperature and pressure, which is the basis for heated vacuum degassing, while helium displaces air because of its very low solubility. Materials contacting medium are PTFE, silicone or stainless steel to prevent leachables.
What are the key features?
- Regulated helium delivery with flow meter and pressure gauge
- Fritted sparger for fine bubble dispersion
- One to six outlet manifold for parallel sparging
- No heating or membrane filtration required
- Suitable for surfactant-containing media
- Optional oxygen sensor and gas-saving timer
What are the technical specifications?
A typical helium sparging dissolution media degassing station configuration offers gas type of helium, purity ≥ 99.995%, gas pressure of 0.1–0.3 MPa regulated, flow rate of 0.1–2 L/min per outlet, outlets of 1–6, sparging time of 5–15 min typical and sparger material of fritted glass or 316 stainless steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Helium Sparging Dissolution Media Degassing Station is used in heat-labile drug dissolution, surfactant media degassing, HPLC mobile phase degassing and methods specifying helium. Across the wider Media Preparation class, laboratories also deploy it for dissolution medium preparation, buffer standardization and degassing for UV and HPLC methods.
Which standards and certifications apply?
Relevant standards and methods include USP <711>, USP <791>, USP <1092>, Ph. Eur. 2.9.3, Ph. Eur. 2.2.3, JP 6.10, ChP 0931 and ASTM E2503. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate pumps gravimetrically and pH sensors with at least two buffers on a regular schedule. Replace membrane filters, tubing and seals at defined intervals, and flush lines after each medium to prevent precipitation and microbial growth, especially with phosphate buffers. Use purified water meeting the method specification. Helium systems need leak-tight fittings and cylinder safety. Record concentrate lot numbers and expiry, and verify final pH at 37 °C where the monograph requires it. Include the equipment in IQ/OQ and preventive maintenance programs.
How do I select the right Helium Sparging Dissolution Media Degassing Station?
Choose helium sparging when heating would degrade the medium, surfactants foam under vacuum, or the monograph specifies helium. Specify the number of outlets, sparger type, regulator range and whether an oxygen probe is needed. Sites without helium supply should consider a vacuum or membrane degasser instead.
How does it compare with other Media Preparation variants?
Match the equipment to daily medium volume, number of buffer recipes and compliance needs. A benchtop vacuum degasser suits laboratories preparing under 20 liters per day by hand. A helium station suits heat-labile or surfactant media. A volumetric dispenser removes filling error for many vessels. A dilution station with pH control reduces salt weighing. A fully automated system combines all steps and records batch data for GMP sites. Evaluate volume accuracy (±1%), dissolved oxygen endpoint, compatible recipes, cleaning and carry-over control, wetted materials, and software audit-trail features. Method validation must show that the degassing approach gives dissolution results equivalent to the compendial procedure.
Full specifications
| Gas type | helium, purity ≥ 99.995% |
|---|---|
| Gas pressure | 0.1–0.3 MPa regulated |
| Flow rate | 0.1–2 L/min per outlet |
| Outlets | 1–6 |
| Sparging time | 5–15 min typical |
| Sparger material | fritted glass or 316 stainless steel |
| Dissolved oxygen | < 4 mg/L after sparging |
| Batch volume | 1–20 L |
| Gas consumption | about 5–20 L per liter of medium |
| Dimensions | about 300 × 250 × 400 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Heat-labile drug dissolution
- Surfactant media degassing
- HPLC mobile phase degassing
- Methods specifying helium
Key features
- Regulated helium delivery with flow meter and pressure gauge
- Fritted sparger for fine bubble dispersion
- One to six outlet manifold for parallel sparging
- No heating or membrane filtration required
- Suitable for surfactant-containing media
- Optional oxygen sensor and gas-saving timer
Frequently asked questions about Helium Sparging Dissolution Media Degassing Station
Helium is very poorly soluble in water, so it displaces dissolved oxygen and nitrogen without being retained itself. It is inert and does not react with analytes, making it suitable for sensitive media.
Five to fifteen minutes is typical, depending on volume, flow and sparger design. Validate the time by measuring dissolved oxygen or comparing dissolution results. Verify the endpoint for each medium.
Yes. Continuous flow consumes gas throughout sparging, so use timers, low-flow settings and proper cylinder management. Vacuum degassing avoids this running cost where helium is scarce.
Dissolved gases form bubbles on tablets, baskets and vessel walls during the test. Bubbles reduce surface contact and alter hydrodynamics, which lowers measured dissolution. USP <711> therefore requires degassing unless validated otherwise.
USP <711> requires that medium volume be within ±1% of the specified volume, such as 900 ± 9 mL. Volumetric dispensers or calibrated glassware are needed to meet this consistently.
Medium is typically preheated to 37–41 °C so vessels equilibrate to 37.0 ± 0.5 °C rapidly. The temperature is verified in each vessel before dosage forms are introduced.