Automated Dissolution Media Preparation System
自动溶出介质配制系统
- SKU MEP-0001
- Media Preparation
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Output capacity | up to 40 L/h |
|---|---|
| Dispensing volume | 100–1000 mL per vessel |
| Volume accuracy | ±1% |
| Mixing ratio accuracy | ±1% v/v |
| Degassing method | vacuum membrane with heating |
| Dissolved oxygen | < 6 mg/L after degassing |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <791>, USP <1092>
What is the Automated Dissolution Media Preparation System?
An automated dissolution media preparation system dilutes buffer concentrate with purified water, degasses the blend and delivers it, heated, to the dissolution vessels in one sequence. It is the right choice for laboratories preparing many liters of medium daily under documented, repeatable conditions.
What is the Automated Dissolution Media Preparation System?
An automated dissolution media preparation system dilutes buffer concentrate with purified water, degasses the blend and delivers it, heated, to the dissolution vessels in one sequence. It is the right choice for laboratories preparing many liters of medium daily under documented, repeatable conditions.
Overview
The system combines a precision dosing pump or proportioning valve, a mixing chamber, an inline degassing module and a heated dispensing line. The operator selects a stored recipe, for example pH 6.8 phosphate buffer or 0.1 N hydrochloric acid, and the instrument draws concentrate and water at the defined ratio, typically verified to ±1% by volume. Inline conductivity or pH sensors confirm composition. Degassing is performed by vacuum membrane or vacuum-plus-heating and reduces dissolved oxygen to levels consistent with USP <711> expectations. Medium is then heated to 37–41 °C and dispensed volumetrically into six or more vessels at 900 ± 1% mL. Flow paths are flushed between recipes to avoid cross-contamination. Electronic batch records capture recipe, lot numbers of concentrate and operator ID, which supports data-integrity requirements and reduces the variability inherent in manual preparation of large volumes.
How does it work?
Dissolution media such as 0.1 N HCl, pH 4.5 acetate buffer and pH 6.8 phosphate buffer must have correct composition, pH, volume, temperature and dissolved gas content. Preparation equipment automates these steps. Proportioning pumps or valves mix concentrate and purified water; pH electrodes and conductivity cells verify composition; degassing removes dissolved gases by vacuum with heat, vacuum membranes, or helium sparging, since gas bubbles on tablets or baskets change local hydrodynamics and surface area; and volumetric dispensers fill vessels to ±1% at 37–41 °C. Gas solubility falls with temperature and pressure, which is the basis for heated vacuum degassing, while helium displaces air because of its very low solubility. Materials contacting medium are PTFE, silicone or stainless steel to prevent leachables.
What are the key features?
- Stored recipes for common compendial buffers and acids
- Proportioning accuracy within ±1% by volume
- Inline vacuum degassing with dissolved-oxygen control
- Heated volumetric dispensing to six or more vessels
- Inline pH or conductivity verification of medium
- Electronic batch record with lot and operator entries
What are the technical specifications?
A typical automated dissolution media preparation system configuration offers output capacity of up to 40 L/h, dispensing volume of 100–1000 mL per vessel, volume accuracy of ±1%, mixing ratio accuracy of ±1% v/v, degassing method of vacuum membrane with heating and dissolved oxygen of < 6 mg/L after degassing. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Dissolution Media Preparation System is used in high-volume QC dissolution labs, multi-buffer methods, generic drug profile studies and GMP-compliant media traceability. Across the wider Media Preparation class, laboratories also deploy it for dissolution medium preparation, buffer standardization and degassing for UV and HPLC methods.
Which standards and certifications apply?
Relevant standards and methods include USP <711>, USP <791>, USP <1092>, Ph. Eur. 2.9.3, Ph. Eur. 2.2.3, JP 6.10, ChP 0931 and ASTM E2503. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate pumps gravimetrically and pH sensors with at least two buffers on a regular schedule. Replace membrane filters, tubing and seals at defined intervals, and flush lines after each medium to prevent precipitation and microbial growth, especially with phosphate buffers. Use purified water meeting the method specification. Helium systems need leak-tight fittings and cylinder safety. Record concentrate lot numbers and expiry, and verify final pH at 37 °C where the monograph requires it. Include the equipment in IQ/OQ and preventive maintenance programs.
How do I select the right Automated Dissolution Media Preparation System?
Choose this system when daily medium volume exceeds roughly 20 liters or multiple buffer recipes run across operators. In an RFQ give the concentrate types, required volume per vessel, number of vessels, degassing requirement, sensor needs and software data-integrity features. For low volume laboratories, a benchtop degasser plus manual preparation is usually enough.
How does it compare with other Media Preparation variants?
Match the equipment to daily medium volume, number of buffer recipes and compliance needs. A benchtop vacuum degasser suits laboratories preparing under 20 liters per day by hand. A helium station suits heat-labile or surfactant media. A volumetric dispenser removes filling error for many vessels. A dilution station with pH control reduces salt weighing. A fully automated system combines all steps and records batch data for GMP sites. Evaluate volume accuracy (±1%), dissolved oxygen endpoint, compatible recipes, cleaning and carry-over control, wetted materials, and software audit-trail features. Method validation must show that the degassing approach gives dissolution results equivalent to the compendial procedure.
Full specifications
| Output capacity | up to 40 L/h |
|---|---|
| Dispensing volume | 100–1000 mL per vessel |
| Volume accuracy | ±1% |
| Mixing ratio accuracy | ±1% v/v |
| Degassing method | vacuum membrane with heating |
| Dissolved oxygen | < 6 mg/L after degassing |
| Outlet temperature | 37–41 °C adjustable |
| Number of recipes | up to 50 |
| pH verification | inline probe, ±0.05 pH |
| Power supply | 220 V AC, 50/60 Hz, about 1.5 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-volume QC dissolution labs
- Multi-buffer methods
- Generic drug profile studies
- GMP-compliant media traceability
Key features
- Stored recipes for common compendial buffers and acids
- Proportioning accuracy within ±1% by volume
- Inline vacuum degassing with dissolved-oxygen control
- Heated volumetric dispensing to six or more vessels
- Inline pH or conductivity verification of medium
- Electronic batch record with lot and operator entries
Frequently asked questions about Automated Dissolution Media Preparation System
Proportioning is typically accurate to within ±1% by volume, verified by inline pH or conductivity. Accuracy depends on pump calibration, concentrate stability and temperature, so periodic gravimetric checks are needed.
It provides validated vacuum degassing inline, which is an accepted alternative if the method validation shows equivalent dissolved-gas levels and dissolution results to the compendial procedure.
Yes, with recipes designed to add surfactant concentrate, but foaming during degassing must be controlled, so low-foam membrane degassing and proper flush cycles are recommended.
Dissolved gases form bubbles on tablets, baskets and vessel walls during the test. Bubbles reduce surface contact and alter hydrodynamics, which lowers measured dissolution. USP <711> therefore requires degassing unless validated otherwise.
USP <711> requires that medium volume be within ±1% of the specified volume, such as 900 ± 9 mL. Volumetric dispensers or calibrated glassware are needed to meet this consistently.
Medium is typically preheated to 37–41 °C so vessels equilibrate to 37.0 ± 0.5 °C rapidly. The temperature is verified in each vessel before dosage forms are introduced.