FTIR Spectrometer for Raw Material Identification
原料鉴别红外光谱仪
- SKU FTR-0001
- FTIR
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Spectral range | 4000–400 cm-1 |
|---|---|
| Resolution | 4 cm-1 typical |
| Wavenumber accuracy | about 0.01 cm-1 at 1900 cm-1 |
| Signal-to-noise ratio | about 30000:1 or better |
| Sampling accessory | ATR with diamond or ZnSe |
| Measurement time | about 10–60 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <854>, USP <197>, USP <197M>
What is the FTIR Spectrometer for Raw Material Identification?
An FTIR spectrometer for raw material identification compares sample spectra with reference libraries to confirm the identity of incoming materials. It is chosen at goods-in testing where fast, non-destructive confirmation is needed.
What is the FTIR Spectrometer for Raw Material Identification?
An FTIR spectrometer for raw material identification compares sample spectra with reference libraries to confirm the identity of incoming materials. It is chosen at goods-in testing where fast, non-destructive confirmation is needed.
Overview
Raw material identification by FTIR compares the sample spectrum with a validated reference library or a pharmacopoeial standard. The instrument is usually a benchtop Fourier transform spectrometer with an ATR accessory, which allows powders, granules and liquids to be measured in seconds with minimal preparation, and a library containing spectra of each material measured under the same conditions. Operating procedures define the wavenumber range, resolution, number of scans and acceptance criteria, which typically require a spectral correlation above a defined threshold along with visual inspection of key bands. Because the method is non-destructive, samples can be returned to the container. Library maintenance and periodic verification with a standard keep results reliable.
How does it work?
An FTIR spectrometer shines broadband infrared light through an interferometer, usually a Michelson type with a moving mirror, and then through or onto the sample. The detector records an interferogram, which a Fourier transform converts into an absorption spectrum from about 4000 to 400 cm-1. Molecular bonds absorb at characteristic frequencies, so the spectrum acts as a fingerprint of the material. Sampling accessories determine how the sample is presented: transmission through a potassium bromide pellet or a liquid cell, attenuated total reflectance for solids and pastes, diffuse reflectance for powders, or a microscope for small particles. Resolution, signal-to-noise ratio, wavenumber accuracy and the condition of the sampling accessory determine whether a spectrum matches the reference.
What are the key features?
- Benchtop Fourier transform spectrometer with ATR
- Measurement in seconds with minimal preparation
- Validated spectral library of materials
- Defined wavenumber range and resolution
- Correlation threshold acceptance criteria
- Non-destructive measurement
What are the technical specifications?
A typical ftir spectrometer for raw material identification configuration offers spectral range of 4000–400 cm-1, resolution of 4 cm-1 typical, wavenumber accuracy of about 0.01 cm-1 at 1900 cm-1, signal-to-noise ratio of about 30000:1 or better, sampling accessory of ATR with diamond or ZnSe and measurement time of about 10–60 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The FTIR Spectrometer for Raw Material Identification is used in goods-in raw material identity, excipient confirmation, incoming container verification and dispensing identity checks. Across the wider FTIR class, laboratories also deploy it for raw material identification at goods-in, excipient identity confirmation and polymorph and crystal form screening.
Which standards and certifications apply?
Relevant standards and methods include USP <854>, USP <197>, USP <197M>, EP 2.2.24, ICH Q2(R2) and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the instrument in a room with stable temperature and low humidity, and keep desiccant fresh, because water vapour and carbon dioxide produce sharp absorption bands that can obscure the fingerprint region. Align the interferometer and check wavenumber accuracy with a polystyrene film or other standard at defined intervals, and record the results. Clean ATR crystals carefully, since scratches and residues change the spectrum, and use a background scan at the same settings as the sample. Handle potassium bromide with a dry atmosphere because it is hygroscopic. Maintain the library and re-verify performance after any accessory or detector change, and retain raw spectra for inspection.
How do I select the right FTIR Spectrometer for Raw Material Identification?
Specify an identification system where goods-in testing must confirm many materials quickly and non-destructively. Confirm spectral range and resolution, ATR crystal material, measurement time, library availability for your materials and software with audit trails. Plan library building and periodic verification.
How does it compare with other FTIR variants?
Choose an FTIR system from the sample form and the test required. For raw material identity, an ATR accessory with a diamond or zinc selenide crystal is convenient because powders and pastes can be measured with minimal preparation, and a benchtop unit with a validated spectral library suits goods-in testing. For polymorph screening and structural confirmation, higher resolution and careful control of sample preparation are needed, and comparisons should use the same accessory and conditions as the reference. Portable or handheld FTIR instruments allow identification through packaging or at the point of sampling. FTIR microscopy is used for particle and contaminant identification. Compare spectral range, resolution, signal-to-noise ratio, accessory options and library software with audit trails.
Full specifications
| Spectral range | 4000–400 cm-1 |
|---|---|
| Resolution | 4 cm-1 typical |
| Wavenumber accuracy | about 0.01 cm-1 at 1900 cm-1 |
| Signal-to-noise ratio | about 30000:1 or better |
| Sampling accessory | ATR with diamond or ZnSe |
| Measurement time | about 10–60 s |
| Library | Validated material spectra |
| Power supply | 220 V, 50 Hz, about 0.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Goods-in raw material identity
- Excipient confirmation
- Incoming container verification
- Dispensing identity checks
Key features
- Benchtop Fourier transform spectrometer with ATR
- Measurement in seconds with minimal preparation
- Validated spectral library of materials
- Defined wavenumber range and resolution
- Correlation threshold acceptance criteria
- Non-destructive measurement
Frequently asked questions about FTIR Spectrometer for Raw Material Identification
Usually between ten seconds and a minute, including placing the sample on the ATR crystal, scanning and comparing with the library. This is much faster than wet chemistry or chromatography, which is why FTIR is popular at goods-in.
By measuring spectra of authenticated reference materials and multiple supplier batches under the same conditions, covering the variation expected in routine samples. The library should be validated and controlled, with changes documented.
Do not release the material. Check sample preparation, crystal cleanliness and background, then re-measure. If the mismatch persists, the material is either a different substance, a different form or contaminated, and should be investigated and quarantined.
The infrared spectrum of the sample is compared with a reference spectrum, a pharmacopoeial reference standard or a library entry. A match across the characteristic absorption bands confirms the molecular identity of the material under the defined sampling conditions.
ATR uses a crystal of high refractive index that the sample contacts. Infrared light undergoes total internal reflection inside the crystal and the evanescent wave probes a thin surface layer, so solids, pastes and liquids can be measured with little or no preparation.
Water and carbon dioxide absorb strongly in the infrared and create sharp rotational bands that can overlap the analyte spectrum, especially in the fingerprint region. Stable humidity, fresh desiccant and an appropriate background scan reduce this interference.
Related models