HPLC Fluorescence Detector
液相色谱荧光检测器
- SKU FLU-0004
- Fluorescence
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Excitation wavelength range | 200–900 nm |
|---|---|
| Emission wavelength range | 250–900 nm |
| Flow cell volume | 8 µL |
| Flow cell pressure limit | up to 20 bar |
| Sensitivity | Raman S/N ≥ 1000 |
| Light source | xenon flash lamp |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <853> Fluorescence Spectroscopy, ASTM E579 Standard Practice for Limit of Detection of Fluorescence, ICH Q2(R2) Validation of analytical procedures
What is the HPLC Fluorescence Detector?
An HPLC fluorescence detector measures the fluorescence of analytes as they elute from a liquid chromatograph. It is chosen for trace quantitation of naturally fluorescent or derivatized compounds where UV detection lacks sensitivity or selectivity.
What is the HPLC Fluorescence Detector?
An HPLC fluorescence detector measures the fluorescence of analytes as they elute from a liquid chromatograph. It is chosen for trace quantitation of naturally fluorescent or derivatized compounds where UV detection lacks sensitivity or selectivity.
Overview
This detector sits at the outlet of an HPLC or UHPLC system and uses a flow cell with a defined volume and path. A xenon or deuterium lamp or an LED excites the eluting analytes, and emission is collected at 90 degrees through a monochromator or filter onto a photomultiplier tube. Excitation and emission wavelengths can be programmed as a time list so the detector follows the analytes as they elute, and some models scan for peak identification. Key performance figures are the Raman signal-to-noise ratio, flow cell volume and dispersion, which affect peak shape and sensitivity. The detector is used with reversed-phase and ion-exchange separations for mycotoxins, vitamins, amino acids, drugs and environmental contaminants, often with pre-column or post-column derivatization to add fluorescence.
How does it work?
A fluorophore absorbs photons at an excitation wavelength, moves to an excited electronic state, loses some energy by non-radiative relaxation, and then emits photons at a longer wavelength when it returns to the ground state. The difference between excitation and emission maxima is the Stokes shift. A fluorescence spectrometer consists of an excitation source such as a xenon arc lamp, laser or LED, excitation and emission monochromators or filters, a sample holder for cuvettes, microplates or flow cells, and a detector such as a photomultiplier tube, avalanche photodiode or CCD. Because the detector is positioned at 90 degrees to the excitation beam, transmitted light is largely excluded and sensitivity can be orders of magnitude higher than absorption methods. Signal intensity depends on quantum yield, concentration, path length and quenching by oxygen, pH or matrix components.
What are the key features?
- Flow cell with low volume for sharp chromatographic peaks
- Programmable excitation and emission wavelength time programs
- Xenon or deuterium lamp with monochromator selection
- Photomultiplier detection with high Raman signal-to-noise
- Compatible with pre-column and post-column derivatization
- Emission scanning for peak identification
What are the technical specifications?
A typical hplc fluorescence detector configuration offers excitation wavelength range of 200–900 nm, emission wavelength range of 250–900 nm, flow cell volume of 8 µL, flow cell pressure limit of up to 20 bar, sensitivity of Raman S/N ≥ 1000 and light source of xenon flash lamp. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The HPLC Fluorescence Detector is used in mycotoxin and vitamin analysis in food, trace drug and metabolite quantitation, amino acid analysis after derivatization and environmental pollutant monitoring. Across the wider Fluorescence class, laboratories also deploy it for pharmaceutical assay and impurity testing, nucleic acid and protein quantitation with fluorescent dyes and water quality monitoring of algae, chlorophyll and fluorescent tracers.
Which standards and certifications apply?
Relevant standards and methods include USP <853> Fluorescence Spectroscopy, ASTM E579 Standard Practice for Limit of Detection of Fluorescence, ICH Q2(R2) Validation of analytical procedures, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install fluorescence instruments away from bright daylight and strong UV sources because stray light raises background. Xenon lamps produce ozone and heat and need adequate ventilation and lamp-hour tracking. Verify wavelength accuracy with reference standards and check sensitivity using the water Raman band or quinine sulfate in dilute sulfuric acid. Fluorescence is highly sensitive to dissolved oxygen, pH, temperature and quenching agents, so control and record these factors. Avoid photobleaching by limiting exposure of strongly fluorescent samples. Clean cuvettes and microplates must be free of fluorescent contaminants, and instrument qualification should follow IEC 61010-1 for safety and internal quality procedures for performance.
How do I select the right HPLC Fluorescence Detector?
Select this detector when UV or diode-array detection cannot reach the required detection limit or selectivity for fluorescent analytes. Specify the excitation and emission wavelengths of your method, the expected flow cell pressure, and whether derivatization is planned. Confirm flow cell volume matches your column dimensions so extra-column dispersion does not broaden early peaks.
How does it compare with other Fluorescence variants?
Select a fluorescence system by the sample format and the sensitivity required. Cuvette-based spectrofluorometers are best for method development and identity work because both excitation and emission wavelengths can be scanned. Microplate readers are the choice for high-throughput screening and enzyme assays in 96, 384 or 1536 wells. Time-resolved instruments measure fluorescence lifetimes and reject short-lived background for assays with long-lived labels. HPLC fluorescence detectors add selective quantitation to chromatographic separations. Portable filter fluorometers serve field water and tracer measurements where wavelength coverage matters less than speed. Compare excitation and emission ranges, stray-light rejection, detector type, minimum detectable concentration and software features such as spectral correction and blank subtraction.
Full specifications
| Excitation wavelength range | 200–900 nm |
|---|---|
| Emission wavelength range | 250–900 nm |
| Flow cell volume | 8 µL |
| Flow cell pressure limit | up to 20 bar |
| Sensitivity | Raman S/N ≥ 1000 |
| Light source | xenon flash lamp |
| Detector | photomultiplier tube |
| Wavelength bandwidth | ≤ 20 nm |
| Data rate | up to 100 Hz |
| Communication | Ethernet / analog output |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Mycotoxin and vitamin analysis in food
- Trace drug and metabolite quantitation
- Amino acid analysis after derivatization
- Environmental pollutant monitoring
Key features
- Flow cell with low volume for sharp chromatographic peaks
- Programmable excitation and emission wavelength time programs
- Xenon or deuterium lamp with monochromator selection
- Photomultiplier detection with high Raman signal-to-noise
- Compatible with pre-column and post-column derivatization
- Emission scanning for peak identification
Frequently asked questions about HPLC Fluorescence Detector
Combining chromatographic separation with fluorescence detection gives both selectivity from retention time and sensitivity from emitted light measured against a dark background. Derivatization can add a fluorescent group to non-fluorescent analytes. Together these features reach detection limits far below those of UV absorbance for suitable compounds.
Yes, a large flow cell adds extra-column volume that broadens peaks and reduces resolution, particularly for narrow early-eluting peaks in UHPLC. A small-volume cell preserves peak shape but can reduce sensitivity because the path is shorter. Match the cell volume to the column and expected peak widths.
Routine care includes flushing the flow cell to remove deposits, checking lamp hours and replacing lamps on schedule, and verifying wavelength accuracy and sensitivity with reference standards. Mobile phases should be filtered and degassed to avoid bubbles and baselines drift. Keep a maintenance log for regulated use.
Fluorescence measures emitted photons against a dark background at 90 degrees to the excitation beam, so even a small number of emitted photons is detectable. Absorbance measures a small difference between two large light intensities. This signal-to-noise advantage lets fluorescence reach picomolar or lower concentrations that absorption methods cannot resolve.
Quenching reduces fluorescence intensity through collisions, energy transfer, dissolved oxygen or absorption of emitted light by the matrix. Control it by deoxygenating with nitrogen, matching solvent and pH to the validated method, diluting the matrix, and correcting with internal standards. Heavy atoms and colored compounds are common quenchers that must be identified during method development.
Standard cuvette instruments are designed for clear solutions, but front-face and solid-sample holders allow powders, films and turbid suspensions to be measured with reduced inner-filter effects. Integrating spheres improve reproducibility for scattering solids. For quantitative work, validated methods and reference materials for the specific matrix are essential because scattering complicates the relationship between intensity and concentration.