Benchtop Fluorescence Spectrophotometer
台式荧光分光光度计
- SKU FLU-0001
- Fluorescence
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Excitation wavelength range | 200–900 nm |
|---|---|
| Emission wavelength range | 200–900 nm |
| Excitation bandwidth | 1–20 nm adjustable |
| Emission bandwidth | 1–20 nm adjustable |
| Wavelength accuracy | ±1.0 nm |
| Sensitivity | water Raman S/N ≥ 150 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <853> Fluorescence Spectroscopy, ASTM E579 Standard Practice for Limit of Detection of Fluorescence, ICH Q2(R2) Validation of analytical procedures
What is the Benchtop Fluorescence Spectrophotometer?
A benchtop fluorescence spectrophotometer records excitation and emission spectra of cuvette samples. It is the general-purpose choice for method development, identity tests and quantitative assays when both excitation and emission wavelengths must be selectable.
What is the Benchtop Fluorescence Spectrophotometer?
A benchtop fluorescence spectrophotometer records excitation and emission spectra of cuvette samples. It is the general-purpose choice for method development, identity tests and quantitative assays when both excitation and emission wavelengths must be selectable.
Overview
This instrument uses a xenon arc lamp and two monochromators, one for excitation and one for emission, so the operator can scan either spectrum and choose slit widths for each. A photomultiplier tube detects the weak emitted light at 90 degrees to the excitation path. Typical coverage is 200 to 900 nm for excitation and 200 to 900 nm for emission, with sensitivity often specified as a signal-to-noise ratio on the water Raman band. The sample compartment accepts standard 10 mm cuvettes, and accessories add temperature control, magnetic stirring, microcells or solid-sample holders. Software corrects spectra for lamp and detector response, subtracts blanks and computes concentrations from calibration curves. This is the standard platform for developing and validating fluorescence methods.
How does it work?
A fluorophore absorbs photons at an excitation wavelength, moves to an excited electronic state, loses some energy by non-radiative relaxation, and then emits photons at a longer wavelength when it returns to the ground state. The difference between excitation and emission maxima is the Stokes shift. A fluorescence spectrometer consists of an excitation source such as a xenon arc lamp, laser or LED, excitation and emission monochromators or filters, a sample holder for cuvettes, microplates or flow cells, and a detector such as a photomultiplier tube, avalanche photodiode or CCD. Because the detector is positioned at 90 degrees to the excitation beam, transmitted light is largely excluded and sensitivity can be orders of magnitude higher than absorption methods. Signal intensity depends on quantum yield, concentration, path length and quenching by oxygen, pH or matrix components.
What are the key features?
- Xenon arc lamp with 200–900 nm excitation and emission coverage
- Dual monochromators with adjustable excitation and emission slit widths
- Photomultiplier detection with high signal-to-noise on water Raman
- Standard 10 mm cuvette holder plus microcell and solid-sample options
- Spectral correction, blank subtraction and concentration software
- Optional Peltier temperature control and magnetic stirring
- Wavelength accuracy verified with holmium oxide and quinine sulfate
What are the technical specifications?
A typical benchtop fluorescence spectrophotometer configuration offers excitation wavelength range of 200–900 nm, emission wavelength range of 200–900 nm, excitation bandwidth of 1–20 nm adjustable, emission bandwidth of 1–20 nm adjustable, wavelength accuracy of ±1.0 nm and sensitivity of water Raman S/N ≥ 150. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Fluorescence Spectrophotometer is used in fluorescence method development and validation, identity and content tests for fluorescent APIs, protein and nucleic acid quantitation and environmental dye and tracer analysis. Across the wider Fluorescence class, laboratories also deploy it for pharmaceutical assay and impurity testing, nucleic acid and protein quantitation with fluorescent dyes and water quality monitoring of algae, chlorophyll and fluorescent tracers.
Which standards and certifications apply?
Relevant standards and methods include USP <853> Fluorescence Spectroscopy, ASTM E579 Standard Practice for Limit of Detection of Fluorescence, ICH Q2(R2) Validation of analytical procedures, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install fluorescence instruments away from bright daylight and strong UV sources because stray light raises background. Xenon lamps produce ozone and heat and need adequate ventilation and lamp-hour tracking. Verify wavelength accuracy with reference standards and check sensitivity using the water Raman band or quinine sulfate in dilute sulfuric acid. Fluorescence is highly sensitive to dissolved oxygen, pH, temperature and quenching agents, so control and record these factors. Avoid photobleaching by limiting exposure of strongly fluorescent samples. Clean cuvettes and microplates must be free of fluorescent contaminants, and instrument qualification should follow IEC 61010-1 for safety and internal quality procedures for performance.
How do I select the right Benchtop Fluorescence Spectrophotometer?
Select this variant when both excitation and emission wavelengths must be scanned or when method development requires adjustable bandwidths. Specify the plates or cuvettes you intend to use, the excitation and emission ranges needed, the target detection limit and whether temperature control is required. If throughput dominates, compare with a microplate reader before deciding.
How does it compare with other Fluorescence variants?
Select a fluorescence system by the sample format and the sensitivity required. Cuvette-based spectrofluorometers are best for method development and identity work because both excitation and emission wavelengths can be scanned. Microplate readers are the choice for high-throughput screening and enzyme assays in 96, 384 or 1536 wells. Time-resolved instruments measure fluorescence lifetimes and reject short-lived background for assays with long-lived labels. HPLC fluorescence detectors add selective quantitation to chromatographic separations. Portable filter fluorometers serve field water and tracer measurements where wavelength coverage matters less than speed. Compare excitation and emission ranges, stray-light rejection, detector type, minimum detectable concentration and software features such as spectral correction and blank subtraction.
Full specifications
| Excitation wavelength range | 200–900 nm |
|---|---|
| Emission wavelength range | 200–900 nm |
| Excitation bandwidth | 1–20 nm adjustable |
| Emission bandwidth | 1–20 nm adjustable |
| Wavelength accuracy | ±1.0 nm |
| Sensitivity | water Raman S/N ≥ 150 |
| Light source | 150 W xenon arc lamp |
| Detector | photomultiplier tube |
| Cuvette path length | 10 mm standard |
| Wavelength scan speed | up to 6000 nm/min |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Fluorescence method development and validation
- Identity and content tests for fluorescent APIs
- Protein and nucleic acid quantitation
- Environmental dye and tracer analysis
Key features
- Xenon arc lamp with 200–900 nm excitation and emission coverage
- Dual monochromators with adjustable excitation and emission slit widths
- Photomultiplier detection with high signal-to-noise on water Raman
- Standard 10 mm cuvette holder plus microcell and solid-sample options
- Spectral correction, blank subtraction and concentration software
- Optional Peltier temperature control and magnetic stirring
- Wavelength accuracy verified with holmium oxide and quinine sulfate
Frequently asked questions about Benchtop Fluorescence Spectrophotometer
Under optimized conditions, quinine sulfate in dilute sulfuric acid can be detected at concentrations in the nanogram per litre range, and many labeled analytes reach picomolar levels. The practical limit depends strongly on blank fluorescence, solvent purity, slit widths and the fluorophore's quantum yield.
Monochromator drives, lamp aging and mechanical wear can shift the wavelength scale, which moves peak positions and changes quantitation. Checking with holmium oxide or a quinine sulfate solution confirms that reported maxima remain correct. Verification frequency depends on use and regulatory requirements, and results should be recorded.
Yes, with a microcell or capillary accessory it can measure volumes as low as 10 to 50 microlitres, though sensitivity falls because the optical path is shorter. For the smallest volumes, a dedicated microvolume or microscope-based system is usually better. Confirm minimum volume and path length against your validated method.
Fluorescence measures emitted photons against a dark background at 90 degrees to the excitation beam, so even a small number of emitted photons is detectable. Absorbance measures a small difference between two large light intensities. This signal-to-noise advantage lets fluorescence reach picomolar or lower concentrations that absorption methods cannot resolve.
Quenching reduces fluorescence intensity through collisions, energy transfer, dissolved oxygen or absorption of emitted light by the matrix. Control it by deoxygenating with nitrogen, matching solvent and pH to the validated method, diluting the matrix, and correcting with internal standards. Heavy atoms and colored compounds are common quenchers that must be identified during method development.
Standard cuvette instruments are designed for clear solutions, but front-face and solid-sample holders allow powders, films and turbid suspensions to be measured with reduced inner-filter effects. Integrating spheres improve reproducibility for scattering solids. For quantitative work, validated methods and reference materials for the specific matrix are essential because scattering complicates the relationship between intensity and concentration.