Time-Resolved Fluorescence Lifetime Spectrometer

时间分辨荧光寿命光谱仪

  • SKU FLU-0003
  • Fluorescence
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • Laser safety class 3B enclosure (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Lifetime range10 ps to 10 ms
Excitation sources375–980 nm pulsed laser diodes
Timing resolution≤ 25 ps per channel
Instrument response function< 200 ps FWHM
Detectorfast photomultiplier / hybrid
Count rateup to 10 MHz
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <853> Fluorescence Spectroscopy, ASTM E579 Standard Practice for Limit of Detection of Fluorescence, ICH Q2(R2) Validation of analytical procedures

What is the Time-Resolved Fluorescence Lifetime Spectrometer?

A time-resolved fluorescence lifetime spectrometer measures how long a fluorophore stays in the excited state after a short light pulse. It is used when lifetime, not just intensity, distinguishes analytes, environments or background signals.

What is the Time-Resolved Fluorescence Lifetime Spectrometer?

A time-resolved fluorescence lifetime spectrometer measures how long a fluorophore stays in the excited state after a short light pulse. It is used when lifetime, not just intensity, distinguishes analytes, environments or background signals.

Overview

This instrument applies pulsed excitation from a laser diode, LED or flash lamp and records the decay of emission over nanoseconds to microseconds. Two common approaches are time-correlated single photon counting, which builds a histogram of photon arrival times, and multichannel scaling or stroboscopic methods for longer lifetimes. Detectors include fast photomultipliers, microchannel plates and hybrid detectors. Because lifetime is largely independent of concentration, light path and excitation intensity, it is robust to quenching and scattering, and it enables fluorescence lifetime imaging when combined with a microscope. Lifetimes in the nanosecond range are reported from fits to single or multi-exponential decay models. The technique supports FRET studies, oxygen sensing, label discrimination and background rejection in complex matrices.

How does it work?

A fluorophore absorbs photons at an excitation wavelength, moves to an excited electronic state, loses some energy by non-radiative relaxation, and then emits photons at a longer wavelength when it returns to the ground state. The difference between excitation and emission maxima is the Stokes shift. A fluorescence spectrometer consists of an excitation source such as a xenon arc lamp, laser or LED, excitation and emission monochromators or filters, a sample holder for cuvettes, microplates or flow cells, and a detector such as a photomultiplier tube, avalanche photodiode or CCD. Because the detector is positioned at 90 degrees to the excitation beam, transmitted light is largely excluded and sensitivity can be orders of magnitude higher than absorption methods. Signal intensity depends on quantum yield, concentration, path length and quenching by oxygen, pH or matrix components.

What are the key features?

  • Pulsed laser diode, LED or flash lamp excitation sources
  • Time-correlated single photon counting and multichannel scaling
  • Lifetime range from picoseconds to milliseconds
  • Fast photomultiplier or hybrid detector options
  • Multi-exponential decay fitting and lifetime imaging software
  • Largely independent of concentration and excitation intensity

What are the technical specifications?

A typical time-resolved fluorescence lifetime spectrometer configuration offers lifetime range of 10 ps to 10 ms, excitation sources of 375–980 nm pulsed laser diodes, timing resolution of ≤ 25 ps per channel, instrument response function of < 200 ps FWHM, detector of fast photomultiplier / hybrid and count rate of up to 10 MHz. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Time-Resolved Fluorescence Lifetime Spectrometer is used in FRET and molecular interaction studies, oxygen and pH sensing with lifetime probes, background rejection in scattering or colored samples and fluorescence lifetime imaging in cell biology. Across the wider Fluorescence class, laboratories also deploy it for pharmaceutical assay and impurity testing, nucleic acid and protein quantitation with fluorescent dyes and water quality monitoring of algae, chlorophyll and fluorescent tracers.

Which standards and certifications apply?

Relevant standards and methods include USP <853> Fluorescence Spectroscopy, ASTM E579 Standard Practice for Limit of Detection of Fluorescence, ICH Q2(R2) Validation of analytical procedures, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and Laser safety class 3B enclosure; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install fluorescence instruments away from bright daylight and strong UV sources because stray light raises background. Xenon lamps produce ozone and heat and need adequate ventilation and lamp-hour tracking. Verify wavelength accuracy with reference standards and check sensitivity using the water Raman band or quinine sulfate in dilute sulfuric acid. Fluorescence is highly sensitive to dissolved oxygen, pH, temperature and quenching agents, so control and record these factors. Avoid photobleaching by limiting exposure of strongly fluorescent samples. Clean cuvettes and microplates must be free of fluorescent contaminants, and instrument qualification should follow IEC 61010-1 for safety and internal quality procedures for performance.

How do I select the right Time-Resolved Fluorescence Lifetime Spectrometer?

Select this variant when the analyte or application requires lifetime information, such as FRET efficiency, oxygen sensing or rejection of short-lived background in a turbid matrix. Specify the excitation wavelengths, expected lifetime range, whether imaging is needed, and the count-rate and timing resolution required for accurate fits. Confirm laser safety classification and calibration references.

How does it compare with other Fluorescence variants?

Select a fluorescence system by the sample format and the sensitivity required. Cuvette-based spectrofluorometers are best for method development and identity work because both excitation and emission wavelengths can be scanned. Microplate readers are the choice for high-throughput screening and enzyme assays in 96, 384 or 1536 wells. Time-resolved instruments measure fluorescence lifetimes and reject short-lived background for assays with long-lived labels. HPLC fluorescence detectors add selective quantitation to chromatographic separations. Portable filter fluorometers serve field water and tracer measurements where wavelength coverage matters less than speed. Compare excitation and emission ranges, stray-light rejection, detector type, minimum detectable concentration and software features such as spectral correction and blank subtraction.

Full specifications

Full specifications
Lifetime range10 ps to 10 ms
Excitation sources375–980 nm pulsed laser diodes
Timing resolution≤ 25 ps per channel
Instrument response function< 200 ps FWHM
Detectorfast photomultiplier / hybrid
Count rateup to 10 MHz
Emission wavelength range300–850 nm
Decay fittingsingle to 4-exponential
Repetition rate1 kHz to 100 MHz
ControlPC with TCSPC software

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • FRET and molecular interaction studies
  • Oxygen and pH sensing with lifetime probes
  • Background rejection in scattering or colored samples
  • Fluorescence lifetime imaging in cell biology

Key features

  • Pulsed laser diode, LED or flash lamp excitation sources
  • Time-correlated single photon counting and multichannel scaling
  • Lifetime range from picoseconds to milliseconds
  • Fast photomultiplier or hybrid detector options
  • Multi-exponential decay fitting and lifetime imaging software
  • Largely independent of concentration and excitation intensity

Frequently asked questions about Time-Resolved Fluorescence Lifetime Spectrometer

Fluorescence lifetime is an intrinsic property of the fluorophore and its environment, so it is largely independent of concentration, excitation intensity, light path and photobleaching. That makes lifetime measurements robust in scattering or absorbing samples and enables sensing of oxygen, pH or binding from lifetime changes rather than intensity changes.